0
F1
F2
Exit and Cancel Changes
Exit and Save/Back 1 Level
Enter / Select
Scroll
In Menu Key Functions
PRINT STRINGS
6WUQ*
&QWUO
5DWH
2II
8VHU
/RDG
&RQW
Off
(default)
F key
On Stable Load
Continuous
CONTROL
Print String Output Rate
Number entry screen
(0-65535 seconds)
Print String Format
Number entry screen
1= Current Wt
(Wt-Unit-Mode )
2= Net Wt
(Wt-Unit-Net )
3= Gross Wt
(Wt-Unit-Grs )
4= Tare Wt
(Wt-Unit-Tare )
5= Total Wt
(Wt-Unit-Total )
6= Total Count
(#Samples-TCNT )
7= Current Wt
(no units or mode )
8=
(Reserved)
9= CR-LF (
)
Affects cont-
inuous mode
only
3ULQW
U)
F)QHW
RF
Configure
Network
2Q2II
FLG
&KQO
QHWLG
Enable RF
ScaleCore ID
RF Channel
Network ID
RF
SETUP
Setup Strings
Print Control
Output Rate
Network ID
2Q
2II
Range 1-254, (20-30)
Range 12-23
Range 0 to 999999
RF Network
Number entry
screens
W0RUG
WWOUG
Total # of RD’s
Total RD’s
(Remote Sensor
Devices)
CONFIGURE
NETWORK
Range 1-4
(default 1)
$OO
3ULUV
ERWK
2II
Sum all Remote Devices
Sum in Pairs
(requires 4 Remotes)
Sum in Pairs + Grand Total
Off, summing disabled
SUM REMOTE SENSOR DEVICES SETUP
F2
Press Simultaneously
6WU(Q
Transmission
Strength
Range 0 to 4
.
20
MSI-8000
Operator’s Manual
Figure 5-1. COMM Set Up Menu
Note
Transmission Strength should be set to the lowest setting possible to
achieve the transmission required. Both the scale/Dyna-Link and the 8000
should be set at the same transmission strength setting.
Table 5-1. Transmission Strength Settings
Setting
RF Power
Level
Transmit
Current
Note
0
10dBm
137mA
Lowest Transmission Power
1
12dBm
155mA
(default on 7300s and 8000s)
2
14dBm
170mA
3
16dBm
188mA
4
18dBm
215mA
Summary of Contents for MSI-8000
Page 1: ...MSI 8000 RF Remote Display Operator s Manual 133063 Rev C ...
Page 2: ......
Page 43: ......