Eco Trolley Manual revision 01/10
12
4.7 PRELIMINARY INSPECTION
Power supply, compressed air supply and Exhauster preparation stages for commissioning do not require
any special knowledge apart from those acquired after reading this manual.
Before starting up the Machine it is necessary to perform some inspections and checks in order to avoid
errors or accidents:
•
ensure that the Exhauster did not suffer any damage during assembly;
•
pay special attention when checking electrical parts, control panels, cables and air lines;
•
check that all external supplies connections are correct;
•
Ensure that all mobile parts can move freely.
4. 8 ADJUSTMENTS AND CHECKS
The Exhauster is tested at the Manufacturer's premises, before shipment. No further adjustment is
necessary.
When starting the Exhauster for the first time, proceed as follows:
•
Set the lever of the interlocked socket switch;
•
open compressed air supply cock; ensure that compressed air regulator reads 5/6 bars;
•
Activate the machine main switch;
•
after being supplied, the Exhauster sets to automatic operation mode. Only the voluntary closure of
the remote starter contact can start the machine.
5 OPERATION
5.1 PERSONNEL
The Exhauster is designed for use by many Operators.
Personnel allowed to work on the Exhauster shall have the following knowledge (or acquire it after suitable
training) and be familiar with the contents of this Manual as well as all Safety-related concerns:
•
General and technical knowledge of suitable level to understand Manual contents;
•
Knowledge of the main health and safety and accident prevention rules;
•
Knowledge of how to behave in an emergency situation, where to find personal protection gear and
how to use it correctly.
Maintainers, apart from the above, shall also have suitable electrical, pneumatic and mechanical Technical
knowledge.
5.2 CONTROL PANEL
Exhauster controls are on the control panel, at Machine front.
Figure 5.2 a -
controls on front panel
KEY:
1.
Motor protection switch;
2.
Power socket protection switch;
3. Hour
counters;
4.
Power on warning light;
5.
Manual filter cleaning button;
6. System
board.
5.3 COMMISSIONING AND USE
To power on the Exhauster proceed as follows:
1.
Connect the plug into the power socket;
2.
Set the motor and power socket protection switches to ON, to set the Machine
ready to start;
3.
Install the compressed air mobile fitting into the fitting and open the compressed air supply cock;
4.
Install the suction tube manifold into the mouthpiece;
5.
Select the machine use mode (manual or automatic);
6.
When one of the suction mouthpieces opens, so that the remote contact closes, the machine starts
and performs set function.
1 2 3
4
5
6