11
Eco Trolley Manual revision 01/10
4.6 CONNECTIONS
To avoid any problem upon Exhauster start-up, follow the instructions below.
4.6.1 PNEUMATIC CONNECTIONS
Figure 4. 6. 1A- Pneumatic System Layout
Connection to the air supply is ensured by a flexible hose secured with screw clamps.
The mobile connection is supplied together with the Exhauster.
The standard Exhauster comes with filter unit and adjuster.
Air supply requirements:
•
Operating pressure: 5 bars
•
Maximum pressure: 10 bars
Connect compressed air supply to the supplied tube, by
inserting a gate valve (to be supplied by Customer) on the
pre-set line so that the supply can be cut off during
maintenance. It is strongly recommended to feed the machine
with dry compressed air.
Compressed air of the supply line must be completely
dry, i.e. treated upstream of the exhauster.
4.6.2 ELECTRIC CONNECTIONS
Figure 4. 6. 3A- Electric System Layout
POWER SUPPLY
Exhauster electrical connections are at the
Customer's charge, under its own responsibility.
The electrical connections of the Exhauster shall
consider:
•
the Laws and Technical standards applicable
at the time of installation in the place of
installation;
•
data indicated on " Nameplate A ".
Make the electrical connections.
•
The machine features a supply cable with a
plug. Connect the plug to an interlocked power
socket of a suitable power.
The electrical system design and components ensure utmost dependability and safety of use. The attached
wiring diagrams will allow identification of all connections and components. Only make the required
electrical connections; do not modify any circuits, calibrations, components, etc. Failure to follow this
warning will be considered as tampering. Before connecting to the mains, ensure that power voltage and
frequency correspond to the specifications indicated on the nameplate.
The power plug is wired at the
factory, please check that the power socket is
plug-compatible and the ground connections have been
carried out as required by the prevailing laws of the country.