Page 2: ...ORKING PROCEDURES 8 3 8 RESIDUAL RISKS 8 3 9 NAMEPLATES 8 4 INSTALLATION 9 4 1 TRANSPORT AND HANDLING 9 4 2 STORAGE 9 4 3 ARRANGEMENTS BEFORE INSTALLATION 9 4 4 ASSEMBLY 10 4 5 SET UP 10 4 6 CONNECTIONS 11 4 6 1 PNEUMATIC CONNECTIONS 11 4 6 2 ELECTRIC CONNECTIONS 11 4 7 PRELIMINARY INSPECTION 12 4 8 ADJUSTMENTS AND CHECKS 12 5 OPERATION 12 5 1 PERSONNEL 12 5 2 CONTROL PANEL 12 5 3 COMMISSIONING AN...

Page 3: ...ee Nameplate A paragraph 3 9 1 3 CERTIFICATION The Machine complies with the prevailing European Union Directives applicable at the moment of its release on the market as detailed in the declaration of conformity 1 4 WARRANTY Machine components are covered by a 12 month twelve month warranty this period starts from the date indicated on the purchase document invoice Warranty does not cover electri...

Page 4: ... installation procedures for any accessories devices and equipment are mentioned and can only be performed by specialised personnel or by the AUTHORISED AFTER SALES CENTRE fully complying with the manufacturer s recommendations and the prevailing health and safety rules It is important to keep this manual in a known place and ensure it is legible for possible future reference In case of damage or ...

Page 5: ...iff metal structure Filtering unit includes dust collection bin Exhauster is completely enclosed by a front metal guard A control panel with controls for operation and adjustment is installed in the main electric panel Power supply connections are made by means of cable with power plug 2 4 DIMENSIONS Overall dimensions are specified under paragraph 2 9 Specifications 2 5 AMBIENT CONDITIONS The Exh...

Page 6: ...9 1 Al Ali September 1997 ref CENELEC EN 60439 1 Al 1995 12 EN 60439 1 All 1996 02 In particular manufacturer used proven components and principles as required by 7 10 of EN 60439 1 Al 1995 12 EN 60439 1 Al1 1996 02 Built in electronic equipment was installed as indicated in the instructions that come with the equipment itself and considering the general criteria for EMC specified in EN 60204 1 ar...

Page 7: ...all be used taking some precautions considering that the operator can come into contact with dangerous chemical products by accident and without being aware of the resulting danger Before use the person in charge of production shall evaluate unit use conditions according to the danger possibly caused by products and take suitable protection measures such as work in a room featuring a guaranteed mi...

Page 8: ...tant to comply with the following rules Ensure that air supply pressure is available and set to specified value max 10 bars Do not start the Exhauster before checking the correct installation and parameters set at operator panel this can be done by running a cycle with no product to be taken in by exhauster Wear the personal protection gear suitable for the product in use Wear clothes with close f...

Page 9: ...to improper lifting and handling of the packed unit 4 2 STORAGE For any long period of inactivity store the Exhauster in a suitable place considering storage environment and time In particular consider allowed temperature range humidity and pollution Store the Exhauster indoors Protect the Exhauster from any shock and stress Protect the Exhauster from humidity and extremely wide temperature ranges...

Page 10: ...TER SALES SERVICE Pay attention to the adhesive nameplates on the machine Should they become damaged or illegible promptly change them For this operation contact the AUTHORISED AFTER SALES SERVICE or the Manufacturer Have any maintenance intervention as per the definition of user given in the foreword section performed by qualified personnel Using spare parts that do not comply with the following ...

Page 11: ... Exhauster electrical connections are at the Customer s charge under its own responsibility The electrical connections of the Exhauster shall consider the Laws and Technical standards applicable at the time of installation in the place of installation data indicated on Nameplate A Make the electrical connections The machine features a supply cable with a plug Connect the plug to an interlocked pow...

Page 12: ...tors Personnel allowed to work on the Exhauster shall have the following knowledge or acquire it after suitable training and be familiar with the contents of this Manual as well as all Safety related concerns General and technical knowledge of suitable level to understand Manual contents Knowledge of the main health and safety and accident prevention rules Knowledge of how to behave in an emergenc...

Page 13: ... of welding device and or condenser discharge units to power sockets 5 5 JOB END The procedure for a voluntary stop is as follows 1 Open the main switch on the power socket and disconnect the power plug 2 Open the main switch on machine control panel 3 Close compressed air supply cock 5 6 DECOMMISSIONING In case of long periods of inactivity or in case of maintenance user shall compulsorily Open a...

Page 14: ...does not meet indicated requirements the following could get damaged Pressure regulator 1 Solenoid valve 2 Filter cartridge 3 Dedusting device 4 Condensate drain Should filter cartridge break this could damage the turbine unit 6 1 Remove the regulator close air feed release any residual air by opening the condensate drain cock remove the upper cover Take the pressure to zero by turning the adjuste...

Page 15: ...ease the condensate by opening the drain cock Operate on the condensate drain of the compressed air filter E Important dispose of the condensate as required by the prevailing rules 6 Motor Cut off power and air supply see relevant procedures in the previous pages Contact Authorised After sales Service 7 Hepa filter Cut off power and air supply see relevant procedures in the previous pages Remove t...

Page 16: ...ure that the vacuum tube does not leak Any leak though small as it may be will move the nylon bag up toward the filter cartridge thus blocking off the machine suction opening and finally break the bag It is necessary to dispose of the collected dust according to the prevailing laws of the country where machine is installed 6 5 ROUTINE MAINTENANCE The following operations shall be performed at the ...

Page 17: ... emptying dust collector bag Damp filter Suction of objects Dedusting device is stuck Faulty solenoid valve Faulty timer No compressed air feed Empty dust collector bag more frequently an excessive quantity of accumulated dust clogs the filter cartridge Check for condensate in the machine accumulation tank Install a filter at machine inlet Check for the correct suction value disconnect tube diam 6...

Page 18: ... Ecologic Trolley 16 K15 41 S Ecologic Trolley 30 K30 1 S 2 Solenoid valve A 9029 B 9018 3 Pressure regulator 1 4 PCX 0001 4 Pressure gauge 35 59 5 Power socket 7606 6 Differential pressure gauge 8153 7 Dedusting device K2 0080 8 Filter cartridge K2 91 Alum 9 Top seal 7860 0106 10 Bottom seal 7867 0106 11 Dust collection bag 99988 12 Vacuum breaker valve Ecologic Trolley 30 only V L P 30 13 Pressu...

Page 19: ...the prevailing laws of the country where the Machine is installed 9 2 MACHINE SCRAPPING Upon unit scrapping separate the plastic parts from any electrical components that shall be sent to different waste disposal centres as per prevailing rules The machine metal parts shall be divided into steel and other metals or alloys and then routed to recycling firms Unit scrapping does not cause any special...

Page 20: ...Eco Trolley Manual revision 01 10 20 Electric circuit diagram ...

Page 21: ...21 Eco Trolley Manual revision 01 10 ...

Page 22: ...tritalia 10x38 0 5A Am F3 Auxiliary fuses Elettritalia 10x38 2 A T1 Transformer Elma Elma 7 0 230 400 0 12 24 K1 Contactor Moller DILM12 01 24V D1 Timer Elcotec GV05 S1 External start microswitch S2 Filter cleaning button Moller M22 D B H1 Line lamp Moller M22 LC W Y1 Solenoid valve H2 Hour counter Revalco HK46024 Q2 Bipolar switch Gewiss GW90026 F1 Fuses line Italweber 10x38 20A Am Regulator Pres...

Page 23: ...23 Eco Trolley Manual revision 01 10 Please see descriptions in Table 8 1 A page 18 1 2 3 4 5 6 7 8 9 10 11 12 A B 17 13 14 15 16 22 18 19 20 21 ...

Page 24: ...TION DATE TO WHICH THIS DECLARATION IS REFERRED COMPLIES WITH THE FOLLOWING DIRECTIVES DIRECTIVE 2006 42 EC MACHINERY DIRECTIVE DIRECTIVE 2006 95 EC LOW VOLTAGE DIRECTIVE DIRECTIVE 2004 108 EC ELECTROMAGNETIC COMPATIBILITY DIRECTIVE FURTHERMORE WE DECLARE THAT THE TECHNICAL DOSSIER HAS BEEN DRAWN UP BY LUCA LUCIA C O C A V SRL VIA R VIA MORANDI 93 40060 TOSCANELLA DI DOZZA BOLOGNA ITALY TEL 39 054...

Page 25: ...n 01 10 Please fill in and return this form by fax for Warranty registration Date Machine model Serial no Year of manufacture To be filled in by the Customer Company name Address Telephone Fax Email Company name of installing firm ...

Page 26: ...Eco Trolley Manual revision 01 10 26 Maintenance log book please fill in at any servicing Date Operation description Signature ...

Page 27: ...27 Eco Trolley Manual revision 01 10 Date Operation description Signature ...

Page 28: ...o Trolley Manual revision 01 10 28 C A V srl Via R Morandi 93 40060 Toscanella di Dozza BO Tel 39 0542 673488 Fax 39 0542 672065 www cavitaly com sales cavitaly com www smaisystem com info smaisystem com ...

Reviews: