English
User manual
22
7. Failure to comply with the one of the paragraphs 4 – 6 indicates the voltage regulator defects.
8. Press
Voltage regulator tester
button to exit the diagnostics mode. Disconnect the cables from
voltage regulator.
5.5.3. COM voltage regulator diagnostics
1. Connect voltage regulator with the bench diagnostic outputs, except B+ output.
2. Turn on the mode of the diagnostics of voltage regulator s pressing the button
Voltage regulator
tester
.
3. Choose the nominated voltage of the diagnosed voltage regulator pressing
12V
button.
4. Connect the bench diagnostic output B+ with the corresponding voltage regulator terminal.
4.1. Wait until the bench reads the voltage regulator data, and proceed the diagnostics.
4.2. The stabilization voltage rate shall reach the nominated value with the possible deviation -
0.2V. There shall not be any values in ERROR sector.
5. Change the nominated stabilization voltage from 13.2 up to 15V with
REGULATION GC
knob. The
measured stabilization voltage rate shall change in proportion to the nominated one.
6. Disconnect ST cable from voltage regulator. ME shall appear in ERROR sector. Connect ST cable
back - ME shall disappear.
7. Disconnect one FLD cable from voltage regulator. EL shall appear in ERROR sector. Connect FLD
cable back - EL shall disappear.
8. Failure to comply with the one of the paragraphs 4.1 – 7 indicates the voltage regulator defects.
9. Press
Voltage regulator tester
button to exit the diagnostics mode. Disconnect the cables from
voltage regulator.
5.6. Starter diagnostics
1. Mount the starter on the working spot.
2. Fix the unit on the working spot.
3. Screw the adapter on the positive terminal of the starter.
4. Connect the power cable B- with the unit body, and bench control connector 50 - with the
control output of the starter solenoid. The terminal of the power cable B+ shall be positioned so
there was no contact with the bench - to avoid short circuit.
5. Press
Alternator & starter tester
to turn on starter diagnostics mode, press button 12V/24V to
choose the required voltage referring to the specifications of the diagnosed unit.
Summary of Contents for MS004 COM
Page 2: ......
Page 85: ...MS004 COM 85 FORD LUCAS HITACHI MAGNETTI MARELLI MITSUBISHI ...
Page 86: ...MS004 COM 86 DELCO REMNY VALEO ...
Page 88: ...MS004 COM 88 ...
Page 89: ...MS004 COM 89 ...
Page 90: ...MS004 COM 90 ...
Page 91: ...MS004 COM 91 ...
Page 92: ...MS004 COM 92 ...
Page 93: ...MS004 COM 93 ...
Page 94: ...MS004 COM 94 ...
Page 95: ...MS004 COM 95 ...
Page 99: ...NOTES ...
Page 100: ......