English
Test bench MS004 COM
19
6. Connect the power cable B-
to the unit body, then connect the power cable В+ to the adapter
at the negative terminal of alternator.
5.3.2. Diagnostics
1. Press
Alternator & starter tester
, then press button
12V/24V
to choose the required voltage
referring to the specifications of the diagnosed alternator.
WARNING!
With the pressing of the button Alternator & starter tester you start the mode of
diagnostics of Lamp alternator types.
2. Connect the bench diagnostic outputs (ref. 3, fig. 3) with the alternator connector terminals.
3. Choose the relevant alternator type on the control panel.
3.1. If the diagnosed alternator is of COM type, wait until the bench identifies ID and TYPE of
alternator.
3.2. If the alternator has a terminal: L, D+, I, IL, 61, the control lamp indicator shall light up.
3.3. If the diagnosed alternator is of COM type, the notification on the mechanical failure MEC
will appear near the indicator ERROR.
4. Rotate the knob
ROTATION SPEED
to the left/right referring to the alternator rotation direction
(commonly, alternators rotate clockwise - if you look from pulley side) and set the rotation speed
within the limits of 100 - 150 rpm.
WARNING!
For the alternators with the freewheel clutches, be more cautious when choosing
the rotation direction.
4.1. Visually inspect if the alternator rotates properly (the alternator shall not vibrate). If there
are the abnormal noises that may inform on the mechanical failure, stop the diagnostics.
5. Check the rotation speed when the generation starts as follows:
5.1. Set the voltage value 14.5V for 12V alternators and 29V for 24V alternators, rotating the knob
REGULATION GC
.
5.2. With
ROTATION SPEED
knob, increase smoothly the speed until the alternator output voltage
is equal to nominated voltage. Most of the operative alternators start generation from 700 - 850
drive revolutions. Some alternators of COM type start generation at the speed higher than 1200,
besides, there are LRC alternators (Load Response Control) that have the temporary delay at
the output voltage variation.
5.3. For Lamp type alternators, the stabilizing voltage value shall be set within 14 - 14.8 V for 12V
alternators, and within 28 - 29.8 V for 24V alternators.
5.4. If the alternator is equipped with the control lamp indicator it shall go off.
Summary of Contents for MS004 COM
Page 2: ......
Page 85: ...MS004 COM 85 FORD LUCAS HITACHI MAGNETTI MARELLI MITSUBISHI ...
Page 86: ...MS004 COM 86 DELCO REMNY VALEO ...
Page 88: ...MS004 COM 88 ...
Page 89: ...MS004 COM 89 ...
Page 90: ...MS004 COM 90 ...
Page 91: ...MS004 COM 91 ...
Page 92: ...MS004 COM 92 ...
Page 93: ...MS004 COM 93 ...
Page 94: ...MS004 COM 94 ...
Page 95: ...MS004 COM 95 ...
Page 99: ...NOTES ...
Page 100: ......