MSC CXC-BT
User Manual
28 / 84
2.10.13
Power and System Management
Signal
Pin
Type
Signal
Level
Power
Rail
Remark /
Tolerance
PU/PD/SR
Description
Source / Target
PWRBTN#
I
CMOS 3.3V Sus
ePU = 10 KΩ
Power button to bring system out of or into Suspend states.
Embedded
Controller
SYS_RESET#
I
CMOS 3.3V Sus 3.3V
ePU = 10 KΩ
Reset button input.
Embedded
Controller
CB_RESET#
O
CMOS 3.3V Sus 3.3V,
24mA
Reset output from module to Carrier Board. Active low. Issued by
module chipset and may result from a low SYS_RESET# input, a low
PWR_OK input, a VCC_12V power input that falls below the
minimum specification, a watchdog timeout, or may be initiated by the
module software.
BT SOC
PWR_OK
I
CMOS 3.3V Sus 12V
ePU = 22 K
Ω
Power OK from main power supply. A high value indicates that the
power is good.
Embedded
Controller
SUS_STAT#
O
CMOS 3.3V Sus 3.3V
Indicates imminent suspend operation; used to notify LPC devices.
BT SOC
SUS_S3#
O
CMOS 3.3V Sus 3.3V, 7mA
Indicates system is in Suspend to RAM state. Active low output.
BT SOC
SUS_S4#
O
CMOS 3.3V Sus 3.3V, 7mA
Indicates system is in Suspend to Disk state. Active low output.
Shorted to SUS_S5#.
BT SOC
SUS_S5#
O
CMOS 3.3V Sus 3.3V, 7mA
Indicates system is in Soft Off state. Active low output.
BT SOC
WAKE0#
I
CMOS 3.3V Sus 3.3V
ePU = 10
KΩ
PCI Express wake-up signal.
BT SOC
WAKE1#
I
CMOS 3.3V Sus 3.3V
ePU = 10 KΩ
General purpose wake up signal. May be used to implement wake-up
on PS2 keyboard or mouse activity.
BT SOC
BATLOW#
I
CMOS 3.3V Sus 3.3V
ePU = 10
KΩ
iPU = 40-50
KΩ
Indicates that external battery is low.
BT SOC,
Embedded
Controller
LID#
I
CMOS 3.3V Sus 12V
ePU = 47
KΩ
iPU = 40-50
KΩ
LID switch. Low active signal used by ACPI operating system for LID
switch.
BT SOC,
Embedded
Controller
SLEEP#
I
CMOS 3.3V Sus 12V
ePU = 47
KΩ
iPU = 40-50
KΩ
Sleep button. Low active signal used by ACPI operating system to
bring the system to sleep state or wake it up again.
BT SOC,
Embedded
Controller
THRM#
I
CMOS 3.3V
3.3V
ePU = 10 KΩ
Input from off-module temperature sensor indicating an over-temp
situation.
Not supported.
Embedded
Controller
THERMTRIP#
O
CMOS 3.3V Sus 3.3V
ePU = 10 KΩ
Active low output indicating that the CPU has entered thermal
shutdown.
Not supported.
Embedded