background image

 

 

 

 

 

 

  

 

 

 

 

 

Programmable Controller

 

Instruction Manual  

 

  

 WARNING

  

 

THIS  MANUAL  MUST  BE  CAREFULLY  READ  BY  ALL  INDIVIDUALS  WHO  HAVE  OR WILL  HAVE 
THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece 
of  complex  equipment,  this  product  will  perform  as  designed  only  if  installed,  used  and  serviced  in 
accordance  with  the  manufacturer’s  instructions.  OTHERWISE,  IT  COULD  FAIL  TO  PERFORM  AS 
DESIGNED  AND  PERSONS  WHO  RELY  ON  THIS  PRODUCT  FOR  THEIR  SAFETY  COULD 
SUSTAIN SEVERE PERSONAL INJURY OR DEATH. 
 

The  warranties  made  by  Mine  Safety  Appliances  Company  with  respect  to  these  Products  are  voided  if  the 
products  are  not  installed,  used  and  serviced  in  accordance  with  the  instructions  in  this  user  guide.  Please 
protect  yourself  and  others  by  following  them.  We  encourage  our  customers  to  write  or  call  regarding  this 
equipment prior to use or for any additional information relative to use or repair. 
 

                                        

Manuel d’instructions

 

 

Veuillez  lire  attentivement  les  instructions  qui  suivent.  Tous  ceux  qui  sont  responsables,  ou  qui 

aurons  la  responsabilité  pour  l’installation,  la  fonctionnalité  ou  l’usage  de  ce  produit  doivent  se 
familiariser  complètement  avec  ses  instructions.  Comme  tout  appareil  complexifié,  ce  produit  peut 

vous  donner  les  résultats  anticipés  seulement  s’il  est  installé,  usagé  et  que  le  service  d’entretien 

sont effectués d’après les instructions du fabricant (ou manufacturier). Sous peine de ne pas suivre 
les instructions ci-incluses, il est possible que cet appareil vous donne des résultats insuffisant. En 
conséquence, les  personnes  qui  dépendront  sur  ce  produit  pour  leur  sécurité  peuvent  être  blessés 
ou mourir.

 

Les  garanties  de  ‘Mine  Safety  Appliances  Company’par  rapport  à  ces  produits  sont  annulés  si  les 

produits  ne  sont  pas  installés,  usagés  et  le  service  maintenus  conformément  aux  instructions 

ciincluses. Veuillez vous protéger ainsi que les autres, en suivant les instructions d’installations. S’il 
v

ous  plaît,  entrez  en  communications  avec  nous  au  sujet  de  ce  produit  avant  l’utilisation  de  ce 

produit ou pour plus amples renseignements, sois pour l’usage ou les réparations.

 

In North America., to contact your nearest stocking location, dial toll-free 1-800-MSA-INST

  

To contact MSA International, dial (724) 776-8626

  

© MINE SAFETY APPLIANCES COMPANY 2012 - All Rights Reserved

  

This manual is available on the internet a

www.MSAsafety.com

  

Manufactured by

  

MSA NORTH AMERICA

  

1000 Cranberry Woods Drive, Cranberry Township, PA 16066

  

 
 
REV 5.1 

 

Apr.  2015 

 

 

 

 

 

 

p/n 10152125

Détecte

ur d’Émanations

 

Summary of Contents for ZGARD CX II

Page 1: ...ment avec ses instructions Comme tout appareil complexifi ce produit peut vous donner les r sultats anticip s seulement s il est install usag et que le service d entretien sont effectu s d apr s les i...

Page 2: ...ufacturers of such components THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED IMPLIED OR STATUTORY AND IS STRICTLY LIMITED TO THE TERMS HEREOF SELLER SPECIFICALLY DISCLAIMS ANY WARRANTY OF...

Page 3: ...llation and as a routine inspection of the system 5 Use only genuine MSA replacement parts when performing any maintenance procedures provided in this manual Failure to do so may seriously impair inst...

Page 4: ...ays 8 3 Section 9 Operation Configuration Set Up Menu Auto Configuration 9 0 Auto Configuration continued 9 1 Auto Configuration continued Caution Warning and Alarm setup 9 2 Zone Assignment External...

Page 5: ...the operating alarm and fault diagnostic status of the system The display is split in two display mode sections Status Display Common LED s for System OK Green Caution Amber Warning Amber and Alarm Re...

Page 6: ...etermine the capacity designation and number of remote gas sensors and configure the controller according to the required application Also refer to the ZGARD CX II controller Installation Outline draw...

Page 7: ...1 500 meters away from the controller The ZGARD CX II Controller does NOT provide operating power for the Remote Relay Modules REMOTE RELAY MODULE SPECIFICATIONS Operating Power 17 27VAC 50 60 Hz or...

Page 8: ...the remote sensors or group of sensors exceeds a predetermined caution threshold then the common Caution LED located above the LCD Screen will indicate a caution event Relay outputs can be pre assigne...

Page 9: ...ntroller can then execute control functions based on each zone By adding optional Remote Relay Modules RRM s distributed control can be achieved in addition to the internal control via the relays insi...

Page 10: ...y 1 42001 Relay 2 Etc 42039 Relay 40 The following data is available for each SENSOR 40xx0 Enable State Gas ID 0 Disabled 1 99 GasID 40xx1 Status 0 OK 1 Fail 2 Caution 4 Warning 8 Alarm 40xx2 Zone Ass...

Page 11: ...ect Zone 1 8 511 518 No Sensors Zone 1 8 Multi State 101 199 Alarm State Sensor 1 99 201 299 Zone Assignment Sensor 1 99 301 399 RS 485 Port Sensor 1 99 401 499 GasID Sensor 1 99 Binary 1 40 Relay Sta...

Page 12: ...es not scan the remote sensors and does not activate any warning or alarm relays An automatic timeout returns the ZGARD CX II to normal operation if no keypad activity is detected for 1 minute while i...

Page 13: ...each their respective warning level then the sensor numbers will be displayed adjacent to the W descriptor Should the number of sensors in a warning condition exceed the physical space provided then a...

Page 14: ...of remote sensors and is sequentially updated every 2 seconds Column1 The term ZONE reports the zone numbers Column2 The term SNS reports the number of sensors allocated to the current Zone Column3 Th...

Page 15: ...9 3 2 1 1 O K 1 9 6 0 P P M C O A L A R M R G 1 0 0 P P M R G 1 0 0 C O 1 Z O N E S N S S T A T U S W 1 2 2 2 1 1 O K A 9 3 3 4 A L A R M 8 1 Section 8 ZGARD CX II Controller LCD Screen Display Featu...

Page 16: ...ZRM is present for zone 2 1 4 0 P P M C O W A R N R G 1 0 0 P P M C Z O N E S N S S T A T U S W 1 4 W A R N A 2 4 W A R N 4 Sensor 1 60ppm alarm 2 45ppm warning Zone 1 ALARM because one or more sensor...

Page 17: ...h is the default setting The third line implies the programmer to change the setting There are 3 options for the auto configuration program A U T O C O N F I G N O C H A N G E E N T E R A C C E P T Op...

Page 18: ...e asked to verify the Warning and Alarm set points Press the menu key to accept and continue A U T O C O N F I G 24 S E N S O R S F O U N D 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 V E R I F Y W A...

Page 19: ...WARNING SETPOINT menu will appear The second line of the display shows the current sensor to be assigned a warning set point level The sensor range is also shown for reference only The third line show...

Page 20: ...E 0 1 R E S C A N E N T E R U P D A T E 17 2 As the ZGARD CX II scans for external relay cards it displays all cards that are found E X T E R N A L R E L A Y C A R D S A C T I V E 0 1 F O U N D 0 1 2...

Page 21: ...hich this WARNING relay is assigned A relay may be assigned to multiple zones 20 1 Press the or key to move through all of the relay numbers 20 2 Press 1 through 8 to add or delete a zone that this WA...

Page 22: ...ntil the desired mode appears 23 2 Next relay number Press the or key to move through all of the relay assignments R E L A Y O P E R A T I O N R E L A Y 1 I N T E R N A L R E L A Y 1 M O D E N O R M A...

Page 23: ...L A Y F O R C A L I B R A T I O N S E N S O R 1 P O R T 1 R A N G E 1 0 0 P P M G A S L E V E L 0 P P M G A S C O S E N S O R R E F R E S H 3 S E C 32 Press the MENU key 33 The TIME SET menu will app...

Page 24: ...0 0 F R A M E 8 N 1 M A C 0 0 1 N X T P R V 0 9 V A L U E E N T E R A C C E P T 36 4 Go to next parameter Press the or key to move through all of the desired parameters Not all parameters are changea...

Page 25: ...Depending on the controller s warning alarm and delay settings the display status and the relay action of the controller may vary Refer to the installation sections of the associated ZGARD CX II Contr...

Page 26: ...This page left blank...

Page 27: ...P Zgard CX II ZGARD RRM Ratings Caution Configuration Labels ZGARD CX II B 0 Gas Monitoring Station Power 17 27VAC 50 60Hz or 24 38VDC 0 3Amp 0 7Amp with strobe AC only Input RS 485 99 ZGARD Sensors m...

Page 28: ......

Page 29: ......

Page 30: ......

Reviews: