5
Version 3.4
Summator-combiner of NMEA signal (sentences)
NC-217
Parameter
Value
Number of bytes sent (received) by ports under 90% of
max. channel capacity:
for 1 sec;
for 20 ms
(50 Hz);
for 10 ms (100 Hz)
10370 bytes (max. 11520 baud);
207 bytes;
103 bytes
Select of transmitted NMEA message
Configurable for each output port (select
from a cadre or input manually)
Operational specifications
IP rating
IP22
Dimensions, mm
340.0х290.5х87.7
Operating temperature, °С
−25 to +55
Limiting temperature, °С
−55 to +75
Weight, kg
3.5
* The range of supply voltage is given in brackets.
1.3
T
HE
P
RODUCT
’
S STRUCTURE AND OPERATION
1.3.1
General description
NC-217 receives NMEA messages via input ports “DATA_IN1” to “DATA_IN4”,
combines line by line the received messages and repeats them simultaneously as a single
packet to the inputs of “DATA_I/O 1” to “DATA_I/О 2” ports. The data packet, received
on the outputs of “DATA_I/O 1” and “DATA_I/O2” ports, is repeated to the ports “OUT1”
to “OUT12” according to the customer’s settings; while there are data on “DATA_I/O 1”,
the Product operates with this port. When there are no data on “DATA_I/O 1”, in a second
the Product switches to the port “DATA_I/O 2” and receives data on this port unless they
are restored on “DATA_I/O 1”. A user may configure data receive and transmission rate
and rules of combining messages by means of a built-in keyboard and LCD. The LCD indi-
cates data activity by backlight of the active port.
Note – Built-in keyboard and LCD are located under the Product’s top cover.
In case of data loss on port “DATA_I/O 1” and data reception on “DATA_I/O 2”,
and in case of NC-217 power supply failure, dry contacts of alarm relay are actuated.
1.3.2
Controls and LED indicators
The Product has a metal casing where functional elements and indicators are located,
see figure 1. For the description of functional elements and indicators, see table 2.