WA R N I N G
!
CAUTION
!
When pulling out and inserting the nozzle holder,
always make sure the contact points are clean and
undamaged.
Do not clean the nozzle with solvent.
The powder gun may not be mounted during
cleaning under any circumstances.
Installing the Nozzle
1. Insert the nozzle tube, make sure to insert the nozzle
holder correctly.
2. Screw the nozzle nut over the nozzle tube.
4. Carefully pull out the nozzle tube (3) without twisting the
gun body (4).
5. Clean the removed nozzle and powder gun with
compressed air.
4
3
General Problem
Possible Cause
Solution
TROUBLESHOOTING GUIDE
Defective fuse on the controller
Error at the high-voltage generation
Defective Cascade in spray gun
Defect electric cable from gun to Controller
Incomplete grounding
No grounding
Compressed air main supply insufficient
Feed air - dosage air ratio incorrect
Worn collector nozzle, propelling nozzle in
the injector
Worn nozzle system
Replace fuse
Contact MS Service
Contact MS Service
Contact MS Service
See chapter Grounding
See chapter Grounding
Check the air supply
Feed air, dosage air check to Controller
Check, Replace
Replace nozzle system
No electrostatics and
no powder output
No electrostatic
(e.g. no wrap around or
no powder adhesion)
Worse wrap around
Back spray
Powder outlet
insufficient
Spray cloud no
longer correct
PA-17-06-R1 (08/2018)
29 / 37
www.carlisleft.com
MAINTENANCE
EN