INSTALLATION
INSTALLATION PREPARATION
NOTE: Remember to read all installation instructions carefully prior to
installation of the unit. For a quicker installation, carefully pre-screen installation
location. Prior to installation of the INTERSECTOR, please complete the
INTERSECTOR worksheet. The worksheet is included with this manual.
Please inspect mounting location to ensure the following criteria are met:
• Mounting height should be between 14 feet and 20 feet.
• Distance from the sensor to the stop bar should not exceed 140 feet.
• Distance from the sensor to the closest detection zone should be at least 50 feet.
• Typical range of the TC-CK1-SBE is 600 feet.
• The TC-CK1-SBE has a detection width of 30 degrees. For best results the sensor
should be mounted at a tilt angle between horizontal to 3 degrees downward plus or
minus the road slope.
• Installation requires a laptop with Internet Explorer version 6.0 or greater, at least
2 GB RAM available, safe cable & Ethernet cable.
TOOL REQUIREMENTS:
To properly install the INTERSECTOR, it is necessary to have the following tools on
hand:
• Angle Meter
• Ethernet Cable Tester
• 7/16” Box Wrench or Socket
• Modular Plug Termination Tool
(Crimp Tool)
The INTERSECTOR is designed to be mounted at a height of 14 to 20 feet on a corner
signal pole or on a mast arm no further than 10 feet from the signal pole. Maximum
offset angle from traffic direction should be ±15 degrees. Mounting outside this range
may reduce performance. Mount the sensor to the pole using stainless steel banding or
bolts (not included). Make sure the sensor is mounted level.
INTERSECTOR ANGLE SETTINGS:
There are two angle settings for the INTERSECTOR; side to side (azimuth) and up and
down (elevation). The azimuth setting is accomplished visually using the gun sight at
the top of the unit. Aim the gun sight across the center of the stop bar region. Check to
ensure that cars should be tracked approximately 30 feet past the stop bar for a left turn
lane. To set the elevation, use the angle meter which is included in the INTERSECTOR
installation kit. The Installation Table Recommended Settings below provides initial
settings for installation, based on the distance to the stop bar. These settings may need
additional adjustment depending on factors such as the slope of the road. Rotating the
unit downward will decrease total range, but will ensure detection closer to the unit.
INTER
SECTOR
Microwave Motion and
Presence Sensor Installation Instructions
MS Sedco INTERSECTOR Installation Instructions
Page 7
INTERSECTOR-1.9Uv092717
!