background image

 

EN     MS AutoHoofClean 

Installing the MS AutoHoofClean

 

1.

 

Drill 2 x 8 mm holes horizontally at 345 mm (see image). Then mount the pump unit with 

the 2 supplied plugs and bolts. 

2.

 

Grab the supplied hose, mount the GK-coupling and the hose clamp onto it. Then connect 

these to output 7. 

3.

 

Put the mat at the desired location.  

4.

 

Ensure that the hose of the pump unit runs to the mat and tie it properly to existing 

installations, for example with the supplied tie wraps. Place the hose in such a way that 
bends or kinds are avoided.  

5.

 

Cut the hose to the correct length so that it can be connected to the mat. Mount the last 

GK-coupling and hose clamp to the hose on the side of the mat. Then connect it to the inlet 
on the mat.  

6.

 

Make sure that clean (tap) water is fed through inlet 4.  

7.

 

Place a jug with MS AutoHoofClean under the pump unit. Connect the transparent hose to 

the dosing unit and ensure that the hose can reach all of the fluid. Connect the transparent 
hose to connection 5 of the pump unit (front connection) and ensure that the hose ends up 
at the bottom of the jug. 

8.

 

 Place the jug with alternative product under connection 6 (rear connection) of the pump 

unit. Connect the hose to connection 6 (rear connection) and make sure that the hose 
comes out at the bottom of the jug. 

9.

 

Insert the plug (8) into the outlet.  

Commissioning of the MS AutoHoofClean

 

 

1.

 

Disconnect the hose at inlet 7 on the pump unit.  

2.

 

Put a bucket underneath outlet 7 to collect the liquids.  

3.

 

Press the water button (1) until water flows out of output 7. 

4.

 

Turn the water knob and “MS HoofClean” (2) until the transparent suction hose is full of 

product and check whether a mixture of water and “MS HoofClean” comes out. Then turn 
the knob back in its original position 

5.

 

Turn the water knob + Alternative product until the transparent suction hose is full of 

product and check whether a mixture of water and the Alternative product comes out. 
Then turn the knob back in its original position. 

6.

 

Reconnect the hose to output 7 on the mat.  

7.

 

Fill the mat by turning the water knob and “MS HoofClean” (2) to the right and then return 

the knob in its original position. 

8.

 

Test it by walking over the mat once and look if the product is present everywhere.  

9.

 

The system now works automatically at the following times.  

 

3 times a day 10 minutes of water + 2.7% main cleaning on Mon, Wed, Fri, Sat 

and Sun at 8:00 am, 4:00 pm and 12:00 am 

 

3 times a day 15 minutes of water + alternative product on Tues and Thurs at 8:00 

AM, 4:00 PM and 12:00 AM 

Summary of Contents for MS AutoHoofClean Pompunit 0605049

Page 1: ...1 MS AutoHoofClean MS AutoHoofClean walk through mat 0605036 0605045 0605046 0605066 MS AutoHoofClean Pompunit 0605054 0605049...

Page 2: ...rmades alternatives Produkt Fonctionnement manuel eau MS Formades autre produit 4 Inlet water Ingang water Einlass Wasser Entr e eau 5 Connection of supply MS HoofClean Ingang MS HoofClean Anschluss Z...

Page 3: ...ders vast aan een paal of hekwerk Befestigen Sie die AHC Matte an einem Pfosten oder Zaun mit den mitgelieferten gro en Kabelbindern Fixez le tapis AHC un poteau ou une cl ture l aide des grands serre...

Page 4: ...ion of the pump unit Connect the hose to connection 6 rear connection and make sure that the hose comes out at the bottom of the jug 9 Insert the plug 8 into the outlet Commissioning of the MS AutoHoo...

Page 5: ...5 6x a day 7 minutes of water every day at 10 40 13 20 18 40 21 20 02 40 5 20...

Page 6: ...onder aansluiting 6 achterste aansluiting van de pompunit Koppel de slang aan aansluiting 6 achterste aansluiting en zorg ervoor dat de slang op de bodem van de kan uitkomt 9 Steek de stekker 8 in he...

Page 7: ...7 6x per dag 7 minuten water iedere dag om 10 40 13 20 18 40 21 20 02 40 5 20...

Page 8: ...ten Fl ssigkeit in Kontakt steht 8 Stellen Sie die Beh lter mit alternatives Produkt unter Anschluss 6 hinterer Anschluss der Pumpeneinheit Schlie en Sie den Schlauch an Anschluss 6 hinterer Anschluss...

Page 9: ...ittwoch Freitag Samstag und Sonntag um 8 00 Uhr 16 00 Uhr und 00 00 Uhr 3x t glich 15 Minuten Wasser alternatives Produkt am Dienstag und Donnerstag um 8 00 Uhr 16 00 Uhr und 00 00 Uhr 6x t glich 7 Mi...

Page 10: ...uantit suffisante sur l entr e 4 7 Placer un bidon de MS AutoHoofClean sous l unit de pompage Raccorder le tuyau transparent l unit de dosage et veiller ce qu il puisse atteindre le fond du bidon 8 Pl...

Page 11: ...e syst me fonctionne automatiquement aux horaires suivants 3x par jour lundi mercredi vendredi samedi et dimanche 10 minutes eau 2 7 HoofClean 8h00 16h00 00h00 UTC 1 3x par jour mardi et jeudi 15 minu...

Page 12: ...12...