background image

 

 

 

 

Copyright © 2022 

Page 13 

 
Insert suitable 
screws and 
dowels. 

 

 

 

 
Remove the 
wallbox again 
from the 
installation rail. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
Drill the pre-
marked holes. 

 

 

 

 

 

Summary of Contents for MCharger Connected S 22 kW

Page 1: ...MCharger Connected S 22 kW Installation and operating manual...

Page 2: ...rticularly important information is marked in this operating manual as follows DANGER This warning alerts you of possible dangers in handling or operating the wallbox that may lead to serious injury o...

Page 3: ...tion of the wallbox 6 Connection to the power grid 15 Connecting the power cable 15 Setting up the wallbox 18 Connection 18 Turn on automatic updates 20 Enable data transfer 20 Create a user 20 User t...

Page 4: ...oting and decommissioning 32 Maintainance 32 Manual updates 32 Cleaning 32 Error diagnosis 33 Decommissioning 36 Disposal instructions 36 CE marking and declaration of conformity 37 Technical data 38...

Page 5: ...There is a danger to life Store these instructions carefully The safety instructions must be available to every user Please note that electricity grid operators energy suppliers or national requireme...

Page 6: ...opened by a qualified electrician because the covers protect the user from access to high electrical voltages DANGER If the wallbox is visibly damaged it must not be used Please contact your installer...

Page 7: ...allbox Nameplate The nameplate on the bottom of the wallbox shows all relevant data of this device Here you will find for example the type designation serial number date of manufacture month year and...

Page 8: ...ousing with pre assembled lower cover and pre assembled socket 1 x Top cover pre assembled not screwed 1 x Installation and operation manual 2 x RFID cards tags for authorization 1 x Bag with 1 x Inst...

Page 9: ...possible tripping points created by the charging cable is below an altitude of 2000m does not become a tripping hazard due to cables lying around offers sufficient space for a safe passage between the...

Page 10: ...where special attention should be paid to when mounting on the wall If the wallbox is not attached to a wall please follow the instructions in the installation manual of the accessory Preparation Rem...

Page 11: ...ith a knife Use the small black rubber grommet for sealing Cable from the top bottom The required opening is provided in the housing Use one of the two gray rubber grommets Cable from the top Use the...

Page 12: ...2 Cable from the rear Break out the opening with a screwdriver and a hammer and then deburr it with a knife After entering the cable use the appropriate marking small triangle on the installation rail...

Page 13: ...2022 Page 9 For the installation from the bottom use the left side mark on the installation rail Draw the mark For a connection cable from the top use the middle marking on the installation rail Draw...

Page 14: ...Page 10 Copyright 2022 For a connection cable from the rear use the right side marking on the installation rail Draw the mark Mark the holes for the installation rail Use a spirit level...

Page 15: ...screws and dowels Use the screws of max 6 mm Use a cylinder head screw Drill the appropriate holes for the wall bracket Attach the installation rail to the wall with the dowels and screws Check the al...

Page 16: ...Page 12 Copyright 2022 Attach the wallbox to the installation rail Press the wallbox firmly against the wall Mark the upper holes...

Page 17: ...Copyright 2022 Page 13 Insert suitable screws and dowels Remove the wallbox again from the installation rail Drill the pre marked holes...

Page 18: ...Page 14 Copyright 2022 Insert the connection cable into the wallbox and use the appropriate gray rubber grommet Attach the wallbox to the installation rail Secure the wallbox with two screws...

Page 19: ...g side it is necessary to provide RCD type A circuit breaker 30mA AC The wallbox already has an integrated DC residual current detection The overcurrent protection device of the electrical supply line...

Page 20: ...ith the stripping pliers The stripping length of the individual wires is 11 13 mm Insert the individual wires of the power cord into the associated terminals To do this open up the orange lever first...

Page 21: ...y of installation Mounting the top cover After the wallbox is mounted and connected to the mains the upper cover must be mounted and screwed on Make sure the seal is in the correct fit before placing...

Page 22: ...assword is not required here In your browser go to the following address https 192 168 42 1 Enter the full address https 192 168 42 1 If you enter the address without https for example the Internet br...

Page 23: ...that you keep the settings If you lose your self selected access data the wallbox can still be reached via LAN Bluetooth via app or if already set up via your home Wi fi network BLE o Here you can ent...

Page 24: ...te this setting under the menu item Connectivity under the heading Cloud In order to use the function you must read the data protection information and activate the function Enable data transfer It is...

Page 25: ...ntication via RFID is not needed you can deactivate it under Wallbox Settings To set up a RFID card tag for a user choose the user and click the Edit button Go via the the Next Step button to the seco...

Page 26: ...according to ISO 14443 3A Mifare Classic are recommended When using individual cards tags please ensure that you hold the card tag antenna in front of the marked area INFORMATION Some RFID cards tags...

Page 27: ...guration for the operation of several wallboxes Password change change your user password for login INFORMATION The menu items displayed vary according to the type of user logged in See the chapter Us...

Page 28: ...a user with the administrator rights can see other users charging activities If you have deactivated the RFID Card function the charging processes will not be assigned to any user and will be availabl...

Page 29: ...ownload button you will be forwarded to the data export in the form of a PDF file INFORMATION In order to be able to carry out a data export you need an internet connection for the wallbox which you c...

Page 30: ...e a cable that meets the requirements of ISO 11898 2 if possible You can easily terminate the wallbox by changing the position of the switch SW5 slide it to the left Connect your wallboxes from one de...

Page 31: ...ngs menu item and enter the charging power available for the charging network Here you are asked for the total power that is to be divided among all the wallboxes belonging to the network After making...

Page 32: ...do this repeat the steps beginning with Add New Device Enter consecutive numbers for the other slave wallboxes in the Slave ID input field You can assign IDs from 1 to 15 for this When configuring mak...

Page 33: ...r charging with this wallbox must be checked Park the electric vehicle in such a way that you can easily reach the charging socket of the vehicle with the charging plug of the charging cable Furthermo...

Page 34: ...ox will display the following screen Vehicle connected As soon as authentication takes place and a vehicle is connected to the wallbox the display changes The charging process can now be started if th...

Page 35: ...is not interrupted If the charging process is stopped from the vehicle in the meantime this counter also stops It continues to count the time as soon as the charging process is resumed At the end of t...

Page 36: ...ess is continued after a pause the display changes back to the charging process The values are only reset after the charging process has ended and the vehicle has been disconnected from the wallbox Ma...

Page 37: ...ble the wallbox or the charging cable have visible signs of visible damage you must not continue to use them Please shut down the wallbox and then call the qualified electrician Error diagnosis If an...

Page 38: ...tch SW 4 0008 Communication error via Ethernet The wallbox could not connect to the internet Check your network settings or use offline mode 0010 Temperature error The temperature is outside of the wa...

Page 39: ...patible Restart the loading process If the error persists contact the manufacturer and provide the error ID 0800 Vehicle error detected An emergency shutdown of the vehicle was detected This can have...

Page 40: ...off via the circuit breaker and the residual current circuit breaker and secured against being switched on again Then remove the wallbox from the wall or the surface by loosening all the screws Dispo...

Page 41: ...000 6 3 2007 A1 2011 EN 61000 6 2 2019 IEC 61851 21 2 2018 EMC Radio part RED ETSI EN 301 489 1 V2 2 3 2019 ETSI EN 301 489 3 V2 1 2 2021 ETSI EN 301 489 17 V 3 2 0 2017 Radio ETSI EN 300 328 V2 2 2 2...

Page 42: ...stic Frequencies RFID 13 5 MHz Wi fi 802 11b g n 2 4 2 5 GHz Bluetooth 2 4 2 5 GHz Radio Characteristic max Antenna Gain Wi fi 20 dBm Bluetooth 20 dBm Mechanical Characteristics Dimensions Housing W x...

Page 43: ...Copyright 2022 Page 39 Dimensions...

Page 44: ...from the delivered product and do not represent an obligation on the part of the manufacturer The manufacturer assumes no responsibility for any loss and or damage that occurs as a result of any infor...

Reviews: