DataTrap II™ Operations Manual - Edition 5.4
50
7.3 Hardware Components
The hardware components needed for conducting a Strain Gauge test include:
• DataTrap II™ Data/VOD Recorder
Strain Upgrade
– P/N: 1-04-06
• DataTrap II™ Data/VOD Recorder
Strain Signal
&
Power Cable
(20m or 100m) – P/N: 1-04-08 or 1-04-09
7.3.1 DataTrap II™ Strain Upgrade
This part number (1-04-06) includes the following equipment:
•
Replacement lid for the
DataTrap II™ Data/VOD Recorder
that includes the electronics to communicate with the
Pre-Amplifiers
and
convert the signal for each channel. — Quantity: 1
• Strain Gauge Pre-Amplifiers
configured for EITHER
120 ohm
or
350 ohm
strain gauges. These units are encased in a steel body for
durability. — Quantity: 8
• Power Cable
to connect the
Signal Conditioner Lid
to the DC out of the
DataTrap II™ Data/VOD Recorder
. — Quantity: 1
• BNC Extension Cables
to connect the channel out from the
Signal Conditioner Lid
to the
Channel In
on the back of the
DataTrap II™
Data/VOD Recorder
. — Quantity: 8
•
Hard sided case to house the
Pre-Amplifiers
and cabling when it is not in use. — Quantity: 1
• Strain Gauge
software to be used with the
DataTrap II™ Data/VOD Recorder
for programing, downloading and analysing the data.
— Quantity: 1 (can be installed on as many computers as desired)
•
Operations Manual — Quantity: 1
7.3.2 DataTrap II™ Strain Signal & Power Cable (20m)
This part number (1-04-08) includes the following equipment:
• Cable
20 metres (65.6 feet) in length required to connect the Pre-Amplifiers to the
DataTrap II™ Data/VOD Recorder
Signal
Conditioner Lid
. — Quantity: 1
This item will allow the user to measure one (1) channel of strain. Multiple cables are required if more than one channel of strain is
required to be measured.
7.3.3 DataTrap II™ Strain Signal & Power Cable (100m)
This part number (1-04-09) includes the following equipment:
•
Cable 100 metres (328 feet) in length required to connect the Pre-Amplifiers to the
DataTrap II™ Data/VOD Recorder
Signal
Conditioner Lid
. — Quantity: 1
This item will allow the user to measure one (1) channel of strain. Multiple cables are required if more than one channel of strain is
required to be measured.
Summary of Contents for DATA TRAP II
Page 5: ...T 1 613 545 0466 F 1 613 542 8029 www mrel com 1 Chapter 1 Getting Started...
Page 7: ...T 1 613 545 0466 F 1 613 542 8029 www mrel com 3 Chapter 2 Introduction...
Page 11: ...T 1 613 545 0466 F 1 613 542 8029 www mrel com 7 Chapter 3 Hardware...
Page 25: ...T 1 613 545 0466 F 1 613 542 8029 www mrel com 21 Chapter 4 Memory And Triggering...
Page 28: ...DataTrap II Operations Manual Edition 5 4 24...
Page 29: ...T 1 613 545 0466 F 1 613 542 8029 www mrel com 25...
Page 30: ...DataTrap II Operations Manual Edition 5 4 26...
Page 50: ...DataTrap II Operations Manual Edition 5 4 46...
Page 51: ...T 1 613 545 0466 F 1 613 542 8029 www mrel com 47 Chapter 7 Strain Gauge Upgrade...
Page 59: ...T 1 613 545 0466 F 1 613 542 8029 www mrel com 55...