10
match with the range of heat conduction oil and temperature.
In order to ensure the correct operation of the machine, it
must be ensured that no air bubbles are in the system, the
outlet is connected to the inlet of the reactor, and the inlet
is connected to the outlet of the reactor.
IX. To add heat conduction medium
Special note: when filling the heat conduction medium, the
heat conduction medium cannot be spilled on the cover plate;
the liquid spilled on the cover plate may cause the heat
conduction medium to penetrate the device electrical device,
which may cause the device to short circuit, electrical failure,
and control system failure; if the heat conduction medium is
explosive, it may cause combustion and explosion.
1. To connect high-low temperature cycle machine with reactor
(1).The connection between the high-low temperature cycle
machine and reactor must be made of stainless steel or other
metal pipes;
(2). To connect with the old-fashioned double glass
reactor: The main part is made of stainless steel bellows. It
is also possible to use thick-walled fluorine hose connections
(protective measures must be taken and fluorine hoses need to