8 Operation
49
5809776/02 EN
Importing a system image over a network connection
You can import the system image over the network connection. This requires
activating the remote update function. The remote update function supports
a connection over the following web browsers:
▪ Chrome version 64 or higher
▪ Internet Explorer version 11 (only with deactivated compatibility mode)
▪ Firefox version 47 or higher
▪ Opera version 38 or higher
Communication between the device and PC is unencrypted.
Only use the remote update function on a secure network.
In order to import the system image over a network connection, proceed as
follows:
1. Call up the configuration menu.
2. Select the menu
Import & Export
.
3. Activate the
remote update
option.
4. Enter the IP address of the device in the web browser of your PC (factory
setting of MControl 7" ETH0:
192.168.165.243
; MControl 10" ETH0:
192.168.165.245
).
5. Log in as administrator (user name admin, password as defined during
commissioning).
6. Select the system image and start the import.
ð
The system image or system settings are imported.
ð
Restart the device to complete the import procedure.
Restoring the system via USB stick
If the device is faulty, you can perform a system restore using a USB stick.
Contact Maschinenfabrik Reinhausen GmbH to receive a USB stick for sys-
tem restoration.
In order to restore the system using a USB stick, proceed as follows:
ü
The device has been switched off.
1. Plug the USB stick into the device.
2. Switch on the device.