Installation, Operation & Maintenance Manual

________________________________________________________________________

IN

S

T

A

L

L

E

R

 

5

Provide unions to facilitate installation 
and disconnect of piping

Steam       

Generator

Field  installed  
power supply

Field installed 1/2” insulated 

steam supply pipe

Drain Valve should be closed

See Page 13 for draining information 

Control cable

(located behind  the wall)

Steam Head (shown with acrylic shield)
See page 7  for Steam Head Installation 
information

Field installed  

water supply line

SteamStart

®

 Control

See page 12
for installation 
information.

tyPICAL Mr.StEAM INStALLAtIoN

 

To avoid unintentional steambath operation, do not locate the control 

where other controls, shower heads, valves, body sprays or similar accessories within the shower 
could cause confusion or interfere with the MrSteam control’s intended use and function.

 

Consult with supplier of acrylic, fiberglass and other 

non-heat resistant enclosures for recommended steamhead location. Use 
Acrylic Shield PN MS-103938. See instructions provided with steam shield.

NOTE: 

For illustrative purposes only. Consult 

with qualified designer, architect or contractor 
for steam room construction details.

IMPORTANT NOTE: 

Install cable in a 

dedicated conduit to allow for replacement. 
Be careful not to strain, staple, pinch or 
otherwise damage the control cable. Do not 
route in conduit with power wires.

IMPORTANT NOTE

:

 

Provide a minimum of (12) inches at 

plumbing end and top of the steam generator or as required 
for servicing. Alternately, provide unions as required to facilitate 
installation and disconnection of the steam generator.

IMPORTANT NOTE: 

The minimum clearance from com-

bustible surfaces is zero all around.

5

5

8

(138)

7

3

4

(197)

1

1

4

(32)

12”

(305)

14

7

8

(378)

1

7

8

(48)

3

3

8

(86)

5

3

16

(132)

2

1

2

(64)

14

3

8

(365)

1

1

2

”(38)

Water Inlet

SteamStart

®

Connection

Steam Outlet

Manual 

Drain 
Valve

Safety Valve

T

o AVoID EQUIPMENt DAMAGE Do Not CoNNECt 

POWER SUPPLY DIRECTLY TO ELEMENT TERMINALS !!!

NOTE:  

For ILLUStrAtIVE PUrPoSES oNLy. 

!

C A U T I O N

!

C A U T I O N

Summary of Contents for Steam@Home 3000

Page 1: ...Steam Home RESIDENTIAL STEAM GENERATOR SYSTEMS Models SAH3000 SAH4500 SAH6000 Installation Operation Maintenance Manual mr steam Feel Good Inc...

Page 2: ...ternal human body temperature and impair the body s ability to regulate its inter nal temperature hyperthermia Limit your use of steam to 10 15 minutes until you are certain of your body s reaction WA...

Page 3: ...Steam Outlet Safety Valve Drip Pan 6 Steam Head Installation 7 Electrical Specifications Field Power Wiring 8 Initial Start Up Checkout 9 Troubleshooting System Status Code 9 Wiring Diagrams Liquid L...

Page 4: ...r glass tile and or for rooms hav ing a ceiling height in excess of 8 feet IMPORTANT NOTE The total room volume allows for a maximum of 60 feet of insulated steam line from the SAH generator to the st...

Page 5: ...face such as tile molded acrylic or fiberglass The ceiling should be sloped to prevent drip ping of condensate If acrylic or fiberglass are used as part of the steam room enclosure Consult with the ma...

Page 6: ...ion and disconnection of piping 11 The SteamStart control may be located inside the steam room or outside of the steam room See SteamStart Installation section pg 12 for specific details NOTE MrSteam...

Page 7: ...fiberglass and other non heat resistant enclosures for recommended steamhead location Use Acrylic Shield PN MS 103938 See instructions provided with steam shield NOTE For illustrative purposes only C...

Page 8: ...from unit to steam head as permitted by codes 3 Insulate steam line using pipe insulation rated 250 F minimum 4 Pitch steam line 1 4 per foot towards steam head or steam generator to avoid valleys and...

Page 9: ...compound is used IMPORTANT NOTE to preserve steam head finish do not use wrench or other tools to tighten DO NOT use abrasive cleansers or chemicals Use only water with mild soap and a non abrasive sp...

Page 10: ...5 Use two wire supply source and equipment 8 Contactor Power Supply Opening Control Connection See page 12 for Wiring Field Wiring Ground Conductor Terminal FIELD POWER WIRING Models SAH3000 SAH4500...

Page 11: ...SteamStart button Replace LLCB if code remains TROUBLESHOOTING ELECTRICAL SHOCK HAZARD MrSteam steam generators are connected to 240V line voltage and contain live electrical com ponents All installa...

Page 12: ...level indicator LED is OFF when no water is detected for more that 5 seconds ON when water level is satisfactory ______________________________________________________________________________________...

Page 13: ...n in closed position Stainless Steel Tank Heating Element Contactor Power Supply Opening Steam Outlet ___________________________________________ Part Description _____________________________________...

Page 14: ...ator Be careful not to strain pinch or otherwise damage the control cable StEP 3 Diagram 4 Remove and discard the peel off paper from the switch housing to expose the adhesive as shown in Diagram 4 St...

Page 15: ...m AromaSteam steamhead recess prior to turning on the steambath Do not place drops in a hot steam head as SERIOUS INJURY CAN RESULT IF YOU DO NOT FOLLOW THIS WARNING Start with one drop to gauge stren...

Page 16: ...____________________________________________________________________________________________________________________________________ 2017 Sussman Automatic Corporation I MrSteam and des A Lifetime of...

Reviews: