SAFETY AND OPERATING INFORMATION

Use the SteamStart

®

 control to turn the steam generator on.  

The SteamStart control will only light up when the steam  
generator is on.  
The steam generator will automatically shut off at 20 minutes,  
to turn the steam generator off manually prior to the automatic shut 
off, press the button on the SteamStart control.
The SteamStart control may blink if the steam generator is not 
functioning properly (see page 9).

 

Do not install or use any SteamStart  

control without reading and understanding the MrSteam steam 
generator Installation and Operation Manual (PN 100467 Rev 3.12 
or higher). Failure to read and understand these instructions may 
result in an inoperative or hazardous installation.
A peel-off warning label has been provided in the Information enve-
lope This label is to be applied to the wall of the installed shower or 
steam enclosure in a conspicuous location.

 

Flush a minimum of two-three hours after the con-

trol has been turned off to insure that the water has cooled.

 

Draining immediately after a steam cycle may 

expose user to scalding water and may expose PVC and other pip-
ing to high temperature water. Check local codes. The unit will refill 
automatically when the control is activated again.

mr

.

steam

®

                                            

  

Steam@Home

®

 

SteamStart

®

 Controls

_________________________________________________________________________

!

W A R N I N G

H

O

M

E

O

W

N

E

R

13

USING Mr.StEAM ESSENtIAL oILS

Enjoy AromaSteam essential oils by placing a drop or two into an 
unheated AromaSteam steamhead as shown in the illustration.  
Only use MrSteam AromaSteam essential oils in the MrSteam

® 

AromaSteam steamhead.

•฀Use฀essential฀oils฀with฀caution.฀Essential฀oils฀are฀for฀

 

external use only. Keep out of reach of children. Essential oils are 
highly concentrated and are potent substances and should not be 
applied directly to the skin as they can be irritants. Use essential 
oils with caution. 

•฀Place฀the฀drops฀into฀the฀MrSteam฀AromaSteam฀steamhead฀recess฀

prior to turning on the steambath. Do not place drops in a hot 
steam head as SERIOUS INJURY CAN RESULT IF YOU DO NOT 
FOLLOW THIS WARNING.

•฀Start฀with฀one฀drop฀to฀gauge฀strength฀and฀suitability.฀Limit฀to฀a฀

maximum of a few drops for a steam bathing session. 

•฀The฀bather฀should฀exit฀the฀steambath฀IMMEDIATELY฀if฀

 

dizziness occurs. If skin irritation occurs stop using the oils imme-
diately. Remove any excess oil by washing in mild soap and water. 
If ingested, rinse mouth with water. Administer water or milk to 
dilute. Contact a physician immediately.

AromaSteam steam head

(install per instructions on pg.7)

Steam emission slot

AromaSteam
10ml bottle with 
integrated dropper

Recess for 

essential oil 

 

Aromatic oils should be added to 

steamhead before turning on the steambath unit.  
DO NOT add oil during steam bathing or when  
the steam head is heated.

STEAM GENERATOR MAINTENANCE

Other than periodic draining, maintenance procedures 
are minimal. Every 2 months, or more often in “hard” 
water areas, the manual drain valve should be opened 
fully flushing out accumulated materials, salts and other 
particles which are natural by-products of boiling water. 

Do not alter or modify any MrSteam products includ-
ing the steam generator or SteamStart controls. 
Doing so may result in an inoperative or hazardous 
installation and will void the warranty.

IMPORTANT NOTE: 

Do not operate any SteamStart  

control with other than a Mr. Steam SAH steam genera-
tor. Doing so may result in an inoperative installation.
This document contains important safety, operation 
and maintenance information. Do not discard this 
document.
Malfunction due to power spikes, lightning, fire, 
freezing or flooding is not covered under the warran-
ty. Discontinue use of the steam generator or control 
if the steam generator is damaged or otherwise not 
functioning 

CArE tIPS For StEAM/StArt AND StEAMHEADS

1. Use only mild soap and water on a soft cloth to clean the control and steamhead.
2. Do not use abrasive cleansers

Tightly close bottles when storing oils.  
Keep bottles away from sources of ignition.

!

C A U T I O N

!

C A U T I O N

!

C A U T I O N

!

C A U T I O N S

!

W A R N I N G

Summary of Contents for Steam@Home 3000

Page 1: ...Steam Home RESIDENTIAL STEAM GENERATOR SYSTEMS Models SAH3000 SAH4500 SAH6000 Installation Operation Maintenance Manual mr steam Feel Good Inc...

Page 2: ...ternal human body temperature and impair the body s ability to regulate its inter nal temperature hyperthermia Limit your use of steam to 10 15 minutes until you are certain of your body s reaction WA...

Page 3: ...Steam Outlet Safety Valve Drip Pan 6 Steam Head Installation 7 Electrical Specifications Field Power Wiring 8 Initial Start Up Checkout 9 Troubleshooting System Status Code 9 Wiring Diagrams Liquid L...

Page 4: ...r glass tile and or for rooms hav ing a ceiling height in excess of 8 feet IMPORTANT NOTE The total room volume allows for a maximum of 60 feet of insulated steam line from the SAH generator to the st...

Page 5: ...face such as tile molded acrylic or fiberglass The ceiling should be sloped to prevent drip ping of condensate If acrylic or fiberglass are used as part of the steam room enclosure Consult with the ma...

Page 6: ...ion and disconnection of piping 11 The SteamStart control may be located inside the steam room or outside of the steam room See SteamStart Installation section pg 12 for specific details NOTE MrSteam...

Page 7: ...fiberglass and other non heat resistant enclosures for recommended steamhead location Use Acrylic Shield PN MS 103938 See instructions provided with steam shield NOTE For illustrative purposes only C...

Page 8: ...from unit to steam head as permitted by codes 3 Insulate steam line using pipe insulation rated 250 F minimum 4 Pitch steam line 1 4 per foot towards steam head or steam generator to avoid valleys and...

Page 9: ...compound is used IMPORTANT NOTE to preserve steam head finish do not use wrench or other tools to tighten DO NOT use abrasive cleansers or chemicals Use only water with mild soap and a non abrasive sp...

Page 10: ...5 Use two wire supply source and equipment 8 Contactor Power Supply Opening Control Connection See page 12 for Wiring Field Wiring Ground Conductor Terminal FIELD POWER WIRING Models SAH3000 SAH4500...

Page 11: ...SteamStart button Replace LLCB if code remains TROUBLESHOOTING ELECTRICAL SHOCK HAZARD MrSteam steam generators are connected to 240V line voltage and contain live electrical com ponents All installa...

Page 12: ...level indicator LED is OFF when no water is detected for more that 5 seconds ON when water level is satisfactory ______________________________________________________________________________________...

Page 13: ...n in closed position Stainless Steel Tank Heating Element Contactor Power Supply Opening Steam Outlet ___________________________________________ Part Description _____________________________________...

Page 14: ...ator Be careful not to strain pinch or otherwise damage the control cable StEP 3 Diagram 4 Remove and discard the peel off paper from the switch housing to expose the adhesive as shown in Diagram 4 St...

Page 15: ...m AromaSteam steamhead recess prior to turning on the steambath Do not place drops in a hot steam head as SERIOUS INJURY CAN RESULT IF YOU DO NOT FOLLOW THIS WARNING Start with one drop to gauge stren...

Page 16: ...____________________________________________________________________________________________________________________________________ 2017 Sussman Automatic Corporation I MrSteam and des A Lifetime of...

Reviews: