mr. steam MS-150E Installation, Operation And Maintenance Manual Download Page 5

mr.steam

®

Installation, Operation & Maintenance Manual

__________________________________________________________________________

3

Materials of construction, room size and special design features such
as large glass areas, all affect the steam generator model selection.

1.

Measure length, width & height in feet of the steam/shower or tub/shower

Multiply the Length ____ x Width_____ x Height _____ =

2. Construction Materials:

ROOM VOLUME

SELECT YOUR MrSteam

Compare your

Room Volume

to the

Chart

below

and select the appropriate model.

In considering the purchase or

use of this steambath system, please note that if
you are pregnant, have a coronary condition, are
in poor health, are being treated for any other
medical condition, or are using medication or
drugs, MrSteam recommends that you obtain the
approval of a physician before use.
For information about this product and safety
issues, please call 1.800.76.STEAM

IMPORTANT NOTES:

For steam rooms constructed of acrylic or
synthetic materials, select next lower-rated
MS model.

The MrSteam Sizing Chart allows for up to 60 feet
of insulated steam piping from the MS generator
to the steam room. If the 60 foot steam piping is
exceeded consult with factory. The steam genera-
tor control locations must be taken into account.
A 30 foot cable is standard. Contact MrSteam to
purchase an optional 60 ft. cable PN 103990-60
for iTempo

®

and AirTempo

®

and PN 104117-60

for iSteam

®

. The maximum cable length is 60 feet.

R E S I D E N T I A L S T E A M G E N E R AT O R S S P E C I F I C AT I O N C H A R T

Amps (for

Wire

Total Adj.

Water Usage

Shipping

Model No.

KW

240v/1PH)†

Size‡

Room Vol.

Gallons††

Dimensions*

Wt. (lbs)**

MS90E

5

21

10

0.67

14½"L x 14¾"H x 6¾"D

MS150E

6

25

8

0.80

14½"L x 14¾"H x 6¾"D

MS225E

7.5

32

8

1.0

14½"L x 14¾"H x 6¾"D

MS400E

9

38

8

1.2

14½"L x 14¾"H x 6¾"D

MSSUPER1E

10

42

8

1.4

17"L x 18½"H x 7

7

8

"D

MSSUPER2E

12

50

6

1.6

17"L x 18½"H x 7

7

8

"D

MSSUPER3E

15

63

4

2.0

17"L x 18½"H x 7

7

8

"D

IMPORTANT NOTES:

• Add C1 suffix to Model No. for 240V/1Ph; Add B1 suffix to Model No. for 208V/1Ph.
• All MrSteam MS Models are cULus Listed and CE approved.

All MS Generators available in 240v/1PH, 208v/1PH and other voltages/phases.
† Amps are for 240/1PH rated units.
‡Wire size (AWG) based on minimum 90˚C rated THHN copper conductors.
Refer to the National Electrical Code for other types of conductors.
See MrSteam Installation and Operation Manual for complete dimensional and installation information.

*Dimensions are for generator only, without

AutoFlush® or plumbing features.

**Shipping weight and pricing are for generator only,

without control or steamhead.

†† Water usage based on 20 minutes of operation.

MrSteam @ Your Fingertips:

Start working smarter with MrSteam’s mobile sizing app,
now available for the iPad

®

, iPod

®

and most smart phones.

Visit

mrsteam.com

to size your generator automatically

or go directly to:

http://isizing.mrsteam.com

27

27

27

27

39

39

39

 

0

-71

72-107

108-161

162-257

258-339

340-411

412-482

Add

 

5

0%

For

 

natural

 

stones:

 

natural

 

marble,

 

stone,

 

shale,

 

glass

 

block

 

or

 

concrete

For acrylic or fiberglass subtract 

4.

 

Total

 

Room

 

Room 

Volume

Add

 

0%

For ceramic or porcelain tile on
cement board or mortar bed

Add

 

40

%

3.

 

Ceiling

 

Height:

 

For

 

each

 

foot

 

above

 

8

 

feet

 

(max

 

10

 

feet)

Add 15% 

to the volume with 

material adjustment 

Summary of Contents for MS-150E

Page 1: ...Inc Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models MS90E MS400E and MSSUPER1E 3E ____________________ IMPORTANT Leave this material with the home owner __...

Page 2: ......

Page 3: ...ur body s reaction The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of provid ing a safe environment for steam room users The peel and...

Page 4: ...team Generator Dimensions 10 Electrical Specifications Field Power Wiring 11 Wiring Diagrams 12 13 Optional Tandem Cable Diagram 13 Initial Start Up Checkout 14 Optional Accessary Equipment 14 Trouble...

Page 5: ...AT I O N C H A RT Amps for Wire Total Adj Water Usage Shipping Model No KW 240v 1PH Size Room Vol Gallons Dimensions Wt lbs MS90E 5 21 10 0 67 14 L x 14 H x 6 D MS150E 6 25 8 0 80 14 L x 14 H x 6 D MS...

Page 6: ...m the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are correct for the incoming line voltage 2 Insure steambath generat...

Page 7: ...on only to prevent damage to the generator IMPORTANT NOTES Items 8 12 8 Install anti water hammer device as necessary 9 Provide a minimum of 12 inches at both ends and top of the steam generator or as...

Page 8: ...Installation information iSteam AirTempo or iTempo Plus Control Refer to Control Installation Manual for installation information Field installed water supply line The control features an integral tem...

Page 9: ...nock outs as shown in diagram Connect each end to the printed circuit board con nector labeled TANDEM as shown 5 Prevent the interconnecting cable from contacting hot surfaces such as steam outlet saf...

Page 10: ...ain valve is provided to facilitate servicing Provide a drain line connection from steambath generator drain valve according to National and local Codes Check local plumb ing code for receptor trap an...

Page 11: ...mark on the nipple where the surface of the wall is Remove the nipple and measure the portion that was in the wall the end to your mark Subtract 1 4 from that dimension and select a brass nipple of th...

Page 12: ...VALVE 3 4 NPT MANUAL DRAIN VALVE 1 2 NPT AUTOFLUSH VALVE 1 2 NPT 1 M Optional AutoFlush 2 All units in inches MM J Water Inlet Control Accessory Connections Steam Outlet Safety Valve Optional AutoFlus...

Page 13: ...or or one that is capable of being locked in the open position 5 For single phase units use two wire supply source and equipment grounding wire Neutral white wire is not required ELECTRICAL CHART ____...

Page 14: ...RD TRANSFORMER POWER INPUT GROUND WATER FEED SOLENOID VALVE FUSES HEATER THERMOSTAT EXPRESS STEAM optional AutoFlush optional HomeWizard iGenie optional iSteam AirTempo iTempo iTempoPlus Control CONTA...

Page 15: ...provided PN 103904 through the knock outs as shown in the Diagram on page 7 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring...

Page 16: ...access panel for inspection INITIAL START UP AND CHECKOUT 1 Turn on control Follow specific instructions provided with controls 2 Steam will begin to appear in approximately 5 minutes unless equipped...

Page 17: ...s LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators ______________________________________________________________________________________________________________________________________ GREEN...

Page 18: ...e must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown 5 The AutoFlush valve must be installed within the orientation range shown DO NOT...

Page 19: ...ble national and local codes Check local plumbing code for receptor trap and vent requirements Condensation pans drain by gravity The condensation pan is equipped with an integral female 3 4 NPT fitti...

Page 20: ...STRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity DO NOT use for wiring repair or other purposes not related to component identification MS SUPER MODELS MSSUPE1E MSSUPER3E w...

Page 21: ...1E MSSUPER2E MSSUPER2E MSSUPER3E MSSUPER3E Drain Valve Safety Valve 15PSI Water Feed Solenoid Valve w filter Transformer 24VAC Liquid Level Control Board Tandem Cable for 2 generators 12 ft Tandem Cab...

Page 22: ...d affix this warning sticker in a conspicuous location may result in serious injury or death Install the iSteam AirTempo iTempo or iTempo Plus controls according to installation instructions Failure t...

Page 23: ...SAVETHESEINSTRUCTIONS The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of providing a safe environ ment for steam room users The peel...

Page 24: ...temperature according to personal preference however it is highly rec ommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels Set duration to a maximum of 10 m...

Page 25: ...they can be irritants Use essential oils with caution 2 Place the drops into the MrSteam AromaSteam steamhead recess prior to turning on the steambath DO NOT place drops in a hot steam head as serous...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...ration I MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy CT Day Spa Digital 1 Express Steam Feel...

Reviews: