mr.steam
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
3
Materials of construction, room size and special design features such
as large glass areas, all affect the steam generator model selection.
1.
Measure length, width & height in feet of the steam/shower or tub/shower
Multiply the Length ____ x Width_____ x Height _____ =
2. Construction Materials:
ROOM VOLUME
SELECT YOUR MrSteam
Compare your
Room Volume
to the
Chart
below
and select the appropriate model.
In considering the purchase or
use of this steambath system, please note that if
you are pregnant, have a coronary condition, are
in poor health, are being treated for any other
medical condition, or are using medication or
drugs, MrSteam recommends that you obtain the
approval of a physician before use.
For information about this product and safety
issues, please call 1.800.76.STEAM
IMPORTANT NOTES:
For steam rooms constructed of acrylic or
synthetic materials, select next lower-rated
MS model.
The MrSteam Sizing Chart allows for up to 60 feet
of insulated steam piping from the MS generator
to the steam room. If the 60 foot steam piping is
exceeded consult with factory. The steam genera-
tor control locations must be taken into account.
A 30 foot cable is standard. Contact MrSteam to
purchase an optional 60 ft. cable PN 103990-60
for iTempo
®
and AirTempo
®
and PN 104117-60
for iSteam
®
. The maximum cable length is 60 feet.
R E S I D E N T I A L S T E A M G E N E R AT O R S S P E C I F I C AT I O N C H A R T
Amps (for
Wire
Total Adj.
Water Usage
Shipping
Model No.
KW
240v/1PH)†
Size‡
Room Vol.
Gallons††
Dimensions*
Wt. (lbs)**
MS90E
5
21
10
0.67
14½"L x 14¾"H x 6¾"D
MS150E
6
25
8
0.80
14½"L x 14¾"H x 6¾"D
MS225E
7.5
32
8
1.0
14½"L x 14¾"H x 6¾"D
MS400E
9
38
8
1.2
14½"L x 14¾"H x 6¾"D
MSSUPER1E
10
42
8
1.4
17"L x 18½"H x 7
7
⁄
8
"D
MSSUPER2E
12
50
6
1.6
17"L x 18½"H x 7
7
⁄
8
"D
MSSUPER3E
15
63
4
2.0
17"L x 18½"H x 7
7
⁄
8
"D
IMPORTANT NOTES:
• Add C1 suffix to Model No. for 240V/1Ph; Add B1 suffix to Model No. for 208V/1Ph.
• All MrSteam MS Models are cULus Listed and CE approved.
All MS Generators available in 240v/1PH, 208v/1PH and other voltages/phases.
† Amps are for 240/1PH rated units.
‡Wire size (AWG) based on minimum 90˚C rated THHN copper conductors.
Refer to the National Electrical Code for other types of conductors.
See MrSteam Installation and Operation Manual for complete dimensional and installation information.
*Dimensions are for generator only, without
AutoFlush® or plumbing features.
**Shipping weight and pricing are for generator only,
without control or steamhead.
†† Water usage based on 20 minutes of operation.
MrSteam @ Your Fingertips:
Start working smarter with MrSteam’s mobile sizing app,
now available for the iPad
®
, iPod
®
and most smart phones.
Visit
mrsteam.com
to size your generator automatically
or go directly to:
http://isizing.mrsteam.com
27
27
27
27
39
39
39
0
-71
72-107
108-161
162-257
258-339
340-411
412-482
Add
5
0%
For
natural
stones:
natural
marble,
stone,
shale,
glass
block
or
concrete
For acrylic or fiberglass subtract
4.
Total
Room
Room
Volume
Add
0%
For ceramic or porcelain tile on
cement board or mortar bed
Add
40
%
3.
Ceiling
Height:
For
each
foot
above
8
feet
(max
10
feet)
Add 15%
to the volume with
material adjustment