R E A D M E F I R S T !

As you follow these instruc-

tions, you will notice warning and caution sym-
bols. This blocked information is important for
the safe and efficient installation and operation
of this generator. These are types of potential
hazards that may occur during installation and
operation:

Indicates a potentially

hazardous situation, which, if not avoided, could
result in death or serious injury.

Indicates a potentially hazardous

situation, which, if not avoided may result in
minor or moderate injury or product damage.

is used to address practices not

related to physical injury.

IMPORTANT NOTE:

This highlights

information that is especially relevant to a
problem-free installation.

All information in these instructions is based on
the latest product information available at the
time of publication. Sussman-Automatic
Corporation reserves the right to make changes
at any time without notice. More current instruc-
tions may be available at www.mrsteam.com.

HYPERTHERMIA

occurs when the internal temperature of the

body reaches a level several degrees above the normal body
temperature of 98.6° F. The symptoms of hyperthermia
include an increase in the internal temperature of the body,
dizziness, lethargy, drowsiness, and fainting. The effects of
hyperthermia include:

mr

.

steam

®

Sussman-Automatic Corporation

®

[email protected] www.mrsteam.com

43-20 34th Street, Long Island City, NY 11101

TEL

: 1 800 76 STEAM

9410 S. La Cienega Blvd. Inglewood CA 90301

TEL

: 1 800 72 STEAM

PUR

 

100472A

 

REV

 

1.2

1

When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:

IMPORTANT SAFETY INSTRUCTIONS

1.

READ AND FOLLOW ALL INSTRUCTIONS

2.

Supervise children at all times.

3.

Steam is hot and can cause

injury or death if improperly used. Steam rooms
contain steam and elevated temperatures.
Please read and observe all warnings in this
manual before installing or using a steam room.

4.

To reduce the risk of injury:

A.

The wet surfaces of steam enclosures

may be slippery. Use care when entering
or leaving.

B.

The steam head is hot. DO NOT touch the

steam head and avoid the steam near
the steam head.

C.

Prolonged use of the steam system can raise

excessively the internal human body tempera-
ture and impair the body’s ability to regulate
its internal temperature (hyperthermia). Limit
your use of steam to 10-15 minutes until you
are certain of your body’s reaction.

The manual supplied with the generator includes a peel and
stick warning label. Its proper use is an essential part of provid-
ing a safe environment for steam room users. The peel and
stick warning label must be applied to the wall of the shower
or steam enclosure, at a point that is visible to all users. Failure
to install this sticker may result in serious injury or death. The
location where this owner's manual is kept shall be written in
the space provided on the label using permanent ink. For a
replacement warning label contact MrSteam customer service
at 1-800-76-STEAM or [email protected].

D.

Excessive temperatures have a high

potential for causing fetal damage
during the early months of preg-
nancy. Pregnancy or possibly preg-
nant women should consult a physi-
cian regarding correct exposure.

E.

Obese persons and persons with a

history of heart disease, low or high
blood pressure, circulatory system
problems, or diabetes should con-
sult a physician before using a
steambath.

F.

Persons using medication should

consult a physician before using a
steambath since some medication
may induce drowsiness while other
medications may affect heart rate,
blood pressure and circulation.

SAVE THESE INSTRUCTIONS

U S A

Designed, Engineered
and Assembled in the

1

REDUCE THE RISK OF OVERHEATING AND SCALDING

1. EXIT IMMEDIATELY IF UNCOMFORTABLE, DIZZY OR SLEEPY.

STAYING TOO LONG IN A HEATED AREA IS CAPABLE OF CAUSING OVERHEATING.

2. SUPERVISE CHILDREN AT ALL TIMES.
3. CHECK WITH A DOCTOR BEFORE USE IF PREGNANT, DIABETIC, IN POOR HEALTH

OR UNDER MEDICAL CARE.

4. BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL,

DRUGS, OR MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS.

5. DO NOT CONTACT STEAM HEAD OR STEAM AT THE STEAM HEAD.

REDUCE THE RISK OF SLIPPING AND FALL INJURY

1. USE CARE WHEN ENTERING OR EXITING THE STEAM ROOM. FLOOR MAY BE SLIPPERY

NOTE: FOR ADDITIONAL SAFETY CONSIDERATIONS SEE OWNER”S MANUAL

WHICH IS KEPT:_______________________________________
THE OWNER’S MANUAL CAN BE FOUND AT WWW.MRSTEAM.COM

USE OF STEAM ROOM IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL CAN BE
DANGEROUS AND CAN RESULT IN INJURY THROUGH SLIP AND FALL OR OTHERWISE.

mr

.

steam

®

43-20 34th Street , Long Island City NY 11101 1 800 76 STEAM www.mrsteam.com

PUR100378 8.18

WARNING

!

a) Failure to perceive heat;
b) Failure to recognize the need to exit the steambath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steambath and
f) Unconsciousness.

The use of alcohol, drugs, or medication can greatly increase the risk of hyperthermia.

Not Actual Size

Summary of Contents for MS-150E

Page 1: ...Inc Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models MS90E MS400E and MSSUPER1E 3E ____________________ IMPORTANT Leave this material with the home owner __...

Page 2: ......

Page 3: ...ur body s reaction The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of provid ing a safe environment for steam room users The peel and...

Page 4: ...team Generator Dimensions 10 Electrical Specifications Field Power Wiring 11 Wiring Diagrams 12 13 Optional Tandem Cable Diagram 13 Initial Start Up Checkout 14 Optional Accessary Equipment 14 Trouble...

Page 5: ...AT I O N C H A RT Amps for Wire Total Adj Water Usage Shipping Model No KW 240v 1PH Size Room Vol Gallons Dimensions Wt lbs MS90E 5 21 10 0 67 14 L x 14 H x 6 D MS150E 6 25 8 0 80 14 L x 14 H x 6 D MS...

Page 6: ...m the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are correct for the incoming line voltage 2 Insure steambath generat...

Page 7: ...on only to prevent damage to the generator IMPORTANT NOTES Items 8 12 8 Install anti water hammer device as necessary 9 Provide a minimum of 12 inches at both ends and top of the steam generator or as...

Page 8: ...Installation information iSteam AirTempo or iTempo Plus Control Refer to Control Installation Manual for installation information Field installed water supply line The control features an integral tem...

Page 9: ...nock outs as shown in diagram Connect each end to the printed circuit board con nector labeled TANDEM as shown 5 Prevent the interconnecting cable from contacting hot surfaces such as steam outlet saf...

Page 10: ...ain valve is provided to facilitate servicing Provide a drain line connection from steambath generator drain valve according to National and local Codes Check local plumb ing code for receptor trap an...

Page 11: ...mark on the nipple where the surface of the wall is Remove the nipple and measure the portion that was in the wall the end to your mark Subtract 1 4 from that dimension and select a brass nipple of th...

Page 12: ...VALVE 3 4 NPT MANUAL DRAIN VALVE 1 2 NPT AUTOFLUSH VALVE 1 2 NPT 1 M Optional AutoFlush 2 All units in inches MM J Water Inlet Control Accessory Connections Steam Outlet Safety Valve Optional AutoFlus...

Page 13: ...or or one that is capable of being locked in the open position 5 For single phase units use two wire supply source and equipment grounding wire Neutral white wire is not required ELECTRICAL CHART ____...

Page 14: ...RD TRANSFORMER POWER INPUT GROUND WATER FEED SOLENOID VALVE FUSES HEATER THERMOSTAT EXPRESS STEAM optional AutoFlush optional HomeWizard iGenie optional iSteam AirTempo iTempo iTempoPlus Control CONTA...

Page 15: ...provided PN 103904 through the knock outs as shown in the Diagram on page 7 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring...

Page 16: ...access panel for inspection INITIAL START UP AND CHECKOUT 1 Turn on control Follow specific instructions provided with controls 2 Steam will begin to appear in approximately 5 minutes unless equipped...

Page 17: ...s LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators ______________________________________________________________________________________________________________________________________ GREEN...

Page 18: ...e must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown 5 The AutoFlush valve must be installed within the orientation range shown DO NOT...

Page 19: ...ble national and local codes Check local plumbing code for receptor trap and vent requirements Condensation pans drain by gravity The condensation pan is equipped with an integral female 3 4 NPT fitti...

Page 20: ...STRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity DO NOT use for wiring repair or other purposes not related to component identification MS SUPER MODELS MSSUPE1E MSSUPER3E w...

Page 21: ...1E MSSUPER2E MSSUPER2E MSSUPER3E MSSUPER3E Drain Valve Safety Valve 15PSI Water Feed Solenoid Valve w filter Transformer 24VAC Liquid Level Control Board Tandem Cable for 2 generators 12 ft Tandem Cab...

Page 22: ...d affix this warning sticker in a conspicuous location may result in serious injury or death Install the iSteam AirTempo iTempo or iTempo Plus controls according to installation instructions Failure t...

Page 23: ...SAVETHESEINSTRUCTIONS The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of providing a safe environ ment for steam room users The peel...

Page 24: ...temperature according to personal preference however it is highly rec ommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels Set duration to a maximum of 10 m...

Page 25: ...they can be irritants Use essential oils with caution 2 Place the drops into the MrSteam AromaSteam steamhead recess prior to turning on the steambath DO NOT place drops in a hot steam head as serous...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...ration I MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy CT Day Spa Digital 1 Express Steam Feel...

Reviews: