mr. steam MS-150E Installation, Operation And Maintenance Manual Download Page 22

DO NOT route iSteam, AirTempo, iTempo/Plus,

iTempo, HomeWizard or iGenie control wiring inside conduit
together with power lines or close to hot water or steam piping.
Doing so may result in an inoperative or hazardous installation.

DO NOT alter or modify any MrSteam product. Doing so may
result in an inoperative or hazardous installation and will void the
UL listing and warranty.

IMPORTANT NOTES:

1. Turn power to the steam generator OFF before connect-

ing the control to the generator. Failure to turn the power
off will result in an inoperable control.

2. DO NOT operate iSteam, AirTempo, iTempo/Plus, iTempo,

HomeWizard or iGenie controls with other than a MrSteam
iSteam, AirTempo, or iTempo compatible steam generator.
MrSteam residential steam generators with serial numbers
lower than 900000, or any other brand of steam generator
are not to be operated with iTempo controls. Doing so
may result in an inoperative or hazardous installation.
If iSteam is used with a generator having serial number
less than 1174000, contact MrSteam technical support for
an upgraded PC board.

3. This document contains important safety, operation and

maintenance information. Leave this document with the
homeowner. Do not discard this document.

4. Discontinue use of the steam generator or control if the

steam generator is damaged or otherwise not functioning
properly. Operating a damaged steam generator may
result in an inoperative or hazardous installation

mr.steam

®

Installation, Operation & Maintenance Manual

_________________________________________________________________________

I

N

S

T

A

L

L

E

R

20

BEFORE INSTALLING

Turn power to the steam generator OFF before connecting the
control to the generator. Failure to turn the power off will result in
an inoperable control.

To avoid unintentional steambath operation,

DO NOT locate the control where other controls, acces-
sories, shower heads, valves, body sprays or similar within
the shower could cause confusion or interfere with the
MrSteam control’s intended use and function.

DO NOT use any iSteam

®

, AirTempo

®

,

iTempo/Plus

®

, iTempo

®

, HomeWizard

®

or iGenie

®

controls

without reading and understanding its own manual and the
MrSteam steam generator Installation and Operation Manual.
Failure to read and understand these instructions may result
in an inoperative or hazardous installation.

A peel and stick warning sticker must be read

and permanently affixed in a conspicuous location near the
steam room. Failure to read and affix this warning sticker in a
conspicuous location may result in serious injury or death. .

Install the iSteam, AirTempo, iTempo or iTempo/Plus controls
according to installation instructions. Failure to install accord-
ing to instructions will result in an inoperative control or haz-
ardous overheating or inadequate heating of the steam room.

If an iSteam, AirTempo, iTempo or iTempo/Plus control is
installed outside the steam room a Remote Temperature
Probe (PN MSTS) must be installed inside the steam room
per installation instructions supplied with the Remote
Temperature Probe. Failure to install according to instructions
will result in an inoperative control and overheating of the
steam room.

CONTROL INSTALLATION

Refer to Control Manual for specific installation requirements

CONTROL ROUGH IN

Refer to Installation Instructions for the specific control

IMPORTANT

 

NOTE:

 

The

 

control

 

cable

 

should

 

be

 

run

 

in

 

a

dedicated

 

1”

 

conduit

 

to

 

facilitate

 

installation

 

and

 

service.

1.

Determine

 

the

 

desired

 

installation

 

location

 

of

 

the

 

con-

trol.

 

The

 

iSteam

®

,

 

AirTempo

®

,

 

iTempo

®

 

and

 

iTempo/Plus

®

controls

 

are

 

designed

 

to

 

be

 

installed

 

inside

 

or

 

outside

 

the

steam

 

room

 

as

 

a

 

matter

 

of

 

personal

 

preference.

 

If

 

the

 

con-

trol

 

is

 

installed

 

inside

 

the

 

steam

 

room

 

the

 

control

 

must

 

be

located:

2.

4 - 5

 

feet

 

above

 

the

 

floor

 

near

 

the

 

bather

 

seating

 

area

3.

The

 

control

 

features

 

an

 

integral

 

temperature

 

sensor.

Locate

 

the

 

control

 

in

 

a

 

location

 

representative

 

of

 

the

desired

 

steam

 

bathing

 

temperatures.

 

DO

 

NOT

 

locate

 

the

control

 

above

 

or

 

near

 

the

 

steam

 

head

 

or

 

direct

 

steam

emissions.

4. On a vertical wall

The

 

iSteam

 

and

 

iTempo

 

control

 

cable

 

length

 

is

 

30

 

feet.

Insure

 

that

 

the

 

control

 

and/or

 

steam

 

generator

 

are

 

locat-

ed

 

accordingly.

 

An

 

optional

 

60

 

foot

 

cable

 

is

 

available,

 

PN

103990-60

 

for

 

AirTempo

 

and

 

iTempo

 

and

 

PN

 

104117-60

 

for

 

iSteam.

 

Contact

 

a

 

MrSteam

 

technical

 

service

 

representative

 

if

 

a

 

60

 

foot

 

cable

 

is

 

required.

 

Excess

 

control

 

cable

 

should

 

be

 

neatly

 

coiled

 

and

 

twisted

 

into

 

a

 

figure

 

8.

 

The

 

AirTempo

 

dongle

 

is

 

provided

 

with

 

a

 

3

 

foot

 

cable.

 

The

 

maximum

 

cable

 

length

 

is

 

60

 

feet.

IMPORTANT

 

NOTES:

• If

 

the

 

control

 

is

 

installed

 

outside

 

the

 

steam

 

room

 

a

 

Remote

Temperature

 

Probe

 

Part

 

Number

 

MSTS

 

must

 

be

 

installed

inside

 

the

 

steam

 

room,

 

depending

 

on

 

the

 

control.

• Insure

 

MrSteam

 

steam

 

generator

 

is

 

iSteam,

 

AirTempo

 

or

iTempo

 

compatible

 

and

 

has

 

a

 

serial

 

number

 

900000

 

or

 

high-

er.

 

If

 

iSteam

 

is

 

used

 

with

 

a

 

generator

 

having

 

serial

 

number

less

 

than

 

1174000,

 

contact

 

MrSteam

 

technical

 

support

 

for

 

an

upgraded

 

PC

 

board.

• See

 

instructions

 

for

 

the

 

MSTS

 

Temperature

 

Probe

 

(located

 

in

the

 

Control

 

Installation

 

Manual

 

related

 

to

 

your

 

specific

 

control

package)

 

before

 

rough-in

 

or

 

installation

 

of

 

control.

Summary of Contents for MS-150E

Page 1: ...Inc Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models MS90E MS400E and MSSUPER1E 3E ____________________ IMPORTANT Leave this material with the home owner __...

Page 2: ......

Page 3: ...ur body s reaction The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of provid ing a safe environment for steam room users The peel and...

Page 4: ...team Generator Dimensions 10 Electrical Specifications Field Power Wiring 11 Wiring Diagrams 12 13 Optional Tandem Cable Diagram 13 Initial Start Up Checkout 14 Optional Accessary Equipment 14 Trouble...

Page 5: ...AT I O N C H A RT Amps for Wire Total Adj Water Usage Shipping Model No KW 240v 1PH Size Room Vol Gallons Dimensions Wt lbs MS90E 5 21 10 0 67 14 L x 14 H x 6 D MS150E 6 25 8 0 80 14 L x 14 H x 6 D MS...

Page 6: ...m the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are correct for the incoming line voltage 2 Insure steambath generat...

Page 7: ...on only to prevent damage to the generator IMPORTANT NOTES Items 8 12 8 Install anti water hammer device as necessary 9 Provide a minimum of 12 inches at both ends and top of the steam generator or as...

Page 8: ...Installation information iSteam AirTempo or iTempo Plus Control Refer to Control Installation Manual for installation information Field installed water supply line The control features an integral tem...

Page 9: ...nock outs as shown in diagram Connect each end to the printed circuit board con nector labeled TANDEM as shown 5 Prevent the interconnecting cable from contacting hot surfaces such as steam outlet saf...

Page 10: ...ain valve is provided to facilitate servicing Provide a drain line connection from steambath generator drain valve according to National and local Codes Check local plumb ing code for receptor trap an...

Page 11: ...mark on the nipple where the surface of the wall is Remove the nipple and measure the portion that was in the wall the end to your mark Subtract 1 4 from that dimension and select a brass nipple of th...

Page 12: ...VALVE 3 4 NPT MANUAL DRAIN VALVE 1 2 NPT AUTOFLUSH VALVE 1 2 NPT 1 M Optional AutoFlush 2 All units in inches MM J Water Inlet Control Accessory Connections Steam Outlet Safety Valve Optional AutoFlus...

Page 13: ...or or one that is capable of being locked in the open position 5 For single phase units use two wire supply source and equipment grounding wire Neutral white wire is not required ELECTRICAL CHART ____...

Page 14: ...RD TRANSFORMER POWER INPUT GROUND WATER FEED SOLENOID VALVE FUSES HEATER THERMOSTAT EXPRESS STEAM optional AutoFlush optional HomeWizard iGenie optional iSteam AirTempo iTempo iTempoPlus Control CONTA...

Page 15: ...provided PN 103904 through the knock outs as shown in the Diagram on page 7 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring...

Page 16: ...access panel for inspection INITIAL START UP AND CHECKOUT 1 Turn on control Follow specific instructions provided with controls 2 Steam will begin to appear in approximately 5 minutes unless equipped...

Page 17: ...s LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators ______________________________________________________________________________________________________________________________________ GREEN...

Page 18: ...e must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown 5 The AutoFlush valve must be installed within the orientation range shown DO NOT...

Page 19: ...ble national and local codes Check local plumbing code for receptor trap and vent requirements Condensation pans drain by gravity The condensation pan is equipped with an integral female 3 4 NPT fitti...

Page 20: ...STRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity DO NOT use for wiring repair or other purposes not related to component identification MS SUPER MODELS MSSUPE1E MSSUPER3E w...

Page 21: ...1E MSSUPER2E MSSUPER2E MSSUPER3E MSSUPER3E Drain Valve Safety Valve 15PSI Water Feed Solenoid Valve w filter Transformer 24VAC Liquid Level Control Board Tandem Cable for 2 generators 12 ft Tandem Cab...

Page 22: ...d affix this warning sticker in a conspicuous location may result in serious injury or death Install the iSteam AirTempo iTempo or iTempo Plus controls according to installation instructions Failure t...

Page 23: ...SAVETHESEINSTRUCTIONS The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of providing a safe environ ment for steam room users The peel...

Page 24: ...temperature according to personal preference however it is highly rec ommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels Set duration to a maximum of 10 m...

Page 25: ...they can be irritants Use essential oils with caution 2 Place the drops into the MrSteam AromaSteam steamhead recess prior to turning on the steambath DO NOT place drops in a hot steam head as serous...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...ration I MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy CT Day Spa Digital 1 Express Steam Feel...

Reviews: