Part No.

Description

Generator

___________________________________________________________________________________________________________

99178MS 
99297 
100479 
10477-3 
104288 
103904 
103917 
103990-60 
104117-30 
104117-60 
MSTS 
MSTS-60 
100476-2 
99012 
103453 
100471-2 
99096MS 
103938RD 
103938SQ 
99314 
29051BMS 
29051CMS 
29061BMS 
29061CMS 
29071BMS 
29071CMS 
29091BMS 
29091CMS 
29101BMS 
29101CMS 
29121BMS 
29121CMS 
29151BMS 
29151CMS 

All Models 
All Models 
All Models 
All Models 
All Models 
All Models 
All Models 
All Models 
All Models 
All Models 
All Models 
All Models 
MS90E-400E, Single phase 
All 3-Phase Models  
MSSuper1E–3E 
All Models 
All Models 
All Models 
All Models 
MSSuper2E–3E 
MS90E  
MS90E  
MS150E 
MS150E 
MS225E 
MS225E 
MS400E 
MS400E 
MSSUPER1E 
MSSUPER1E 
MSSUPER2E 
MSSUPER2E 
MSSUPER3E 
MSSUPER3E

Drain Valve 
Safety Valve 15PSI 
Water Feed Solenoid Valve w/filter 
Transformer 24VAC 
Liquid Level Control Board 
Tandem Cable for 2 generators (12 ft.) 
Tandem Cable for up to 5 generators (30 ft.) 
Cable for iTempo® Control (60 ft.) 
Cable for iSteam®, AirTempo® & iTempo/Plus® (30 ft.) 
Cable for iSteam (60 ft) 
Remote Temperature Probe (integral 30ft cable) 
Remote Temperature Probe (integral 60ft cable) 
Contactor 50A 2-pole 
Contactor 50A 3-pole 
Contactor 50A 4-pole 
Probe Assembly 
Heating Element Gasket 
Acrylic Shield for Round Steamhead 
Acrylic Shield for Square Steamhead 
Power Fuse 60A 250V 
Heating Element 5 KW 208V Single Phase 
Heating Element 5 KW 240V Single Phase 
Heating Element 6 KW 208V Single Phase 
Heating Element 6 KW 240V Single Phase 
Heating Element 7.5 KW 208V Single Phase 
Heating Element 7.5 KW 240V Single Phase 
Heating Element 9 KW 208V Single Phase 
Heating Element 9 KW 240V Single Phase 
Heating Element 10 KW 208V Single Phase 
Heating Element 10 KW 240V Single Phase 
Heating Element 12 KW 208V Single Phase 
Heating Element 12 KW 240V Single Phase 
Heating Element 15 KW 208V Single Phase 
Heating Element 15 KW 240V Single Phase

For other voltages and phases contact MrSteam

Summary of Contents for MS-150E

Page 1: ...Inc Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models MS90E MS400E and MSSUPER1E 3E ____________________ IMPORTANT Leave this material with the home owner __...

Page 2: ......

Page 3: ...ur body s reaction The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of provid ing a safe environment for steam room users The peel and...

Page 4: ...team Generator Dimensions 10 Electrical Specifications Field Power Wiring 11 Wiring Diagrams 12 13 Optional Tandem Cable Diagram 13 Initial Start Up Checkout 14 Optional Accessary Equipment 14 Trouble...

Page 5: ...AT I O N C H A RT Amps for Wire Total Adj Water Usage Shipping Model No KW 240v 1PH Size Room Vol Gallons Dimensions Wt lbs MS90E 5 21 10 0 67 14 L x 14 H x 6 D MS150E 6 25 8 0 80 14 L x 14 H x 6 D MS...

Page 6: ...m the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are correct for the incoming line voltage 2 Insure steambath generat...

Page 7: ...on only to prevent damage to the generator IMPORTANT NOTES Items 8 12 8 Install anti water hammer device as necessary 9 Provide a minimum of 12 inches at both ends and top of the steam generator or as...

Page 8: ...Installation information iSteam AirTempo or iTempo Plus Control Refer to Control Installation Manual for installation information Field installed water supply line The control features an integral tem...

Page 9: ...nock outs as shown in diagram Connect each end to the printed circuit board con nector labeled TANDEM as shown 5 Prevent the interconnecting cable from contacting hot surfaces such as steam outlet saf...

Page 10: ...ain valve is provided to facilitate servicing Provide a drain line connection from steambath generator drain valve according to National and local Codes Check local plumb ing code for receptor trap an...

Page 11: ...mark on the nipple where the surface of the wall is Remove the nipple and measure the portion that was in the wall the end to your mark Subtract 1 4 from that dimension and select a brass nipple of th...

Page 12: ...VALVE 3 4 NPT MANUAL DRAIN VALVE 1 2 NPT AUTOFLUSH VALVE 1 2 NPT 1 M Optional AutoFlush 2 All units in inches MM J Water Inlet Control Accessory Connections Steam Outlet Safety Valve Optional AutoFlus...

Page 13: ...or or one that is capable of being locked in the open position 5 For single phase units use two wire supply source and equipment grounding wire Neutral white wire is not required ELECTRICAL CHART ____...

Page 14: ...RD TRANSFORMER POWER INPUT GROUND WATER FEED SOLENOID VALVE FUSES HEATER THERMOSTAT EXPRESS STEAM optional AutoFlush optional HomeWizard iGenie optional iSteam AirTempo iTempo iTempoPlus Control CONTA...

Page 15: ...provided PN 103904 through the knock outs as shown in the Diagram on page 7 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring...

Page 16: ...access panel for inspection INITIAL START UP AND CHECKOUT 1 Turn on control Follow specific instructions provided with controls 2 Steam will begin to appear in approximately 5 minutes unless equipped...

Page 17: ...s LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators ______________________________________________________________________________________________________________________________________ GREEN...

Page 18: ...e must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown 5 The AutoFlush valve must be installed within the orientation range shown DO NOT...

Page 19: ...ble national and local codes Check local plumbing code for receptor trap and vent requirements Condensation pans drain by gravity The condensation pan is equipped with an integral female 3 4 NPT fitti...

Page 20: ...STRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity DO NOT use for wiring repair or other purposes not related to component identification MS SUPER MODELS MSSUPE1E MSSUPER3E w...

Page 21: ...1E MSSUPER2E MSSUPER2E MSSUPER3E MSSUPER3E Drain Valve Safety Valve 15PSI Water Feed Solenoid Valve w filter Transformer 24VAC Liquid Level Control Board Tandem Cable for 2 generators 12 ft Tandem Cab...

Page 22: ...d affix this warning sticker in a conspicuous location may result in serious injury or death Install the iSteam AirTempo iTempo or iTempo Plus controls according to installation instructions Failure t...

Page 23: ...SAVETHESEINSTRUCTIONS The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of providing a safe environ ment for steam room users The peel...