mr. steam MS-150E Installation, Operation And Maintenance Manual Download Page 10

STEAM PIPING (

1

2

" NPT)

1. DO NOT install any valve in steam piping. Flow of steam must

be unobstructed.

2. Use 1/2-inch brass pipe or copper tubing from unit to steam

head as permitted by codes.

3. Insulate steam piping with fiberglass pipe insulation or similar

insulation rated 212° F or higher.

4. Pitch steam piping1/4" per foot towards steam head or steam

generator to avoid valleys and trapping of condensate.

mr.steam

®

Installation, Operation & Maintenance Manual

_________________________________________________________________________

INST

ALLER

INSTALLATION

PLUMBING

All plumbing shall be performed by a qualified licensed plumber

and in accordance with applicable National and local codes.
1. Use unions on all pipe connections.
2. Use only brass piping or rigid copper tubing as permitted

by codes.

3. DO NOT use black, galvanized, PVC pipe or PEX except as

noted below.

WATER SUPPLY (

3

8

" NPT)

1. Connect to cold water line.

Water feed line may be flexible copper tubing,

braided hose, PVC or PEX if permissible by local codes.
2. Provide a shut off valve in the water supply line upstream of

the steambath generator.

3. DO NOT overheat inlet solenoid valve with solder connections.

Overheating will damage parts.

Steam

Steam

Generator

Steam

Generator

Steam

Generator

Steam

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam

Generator

Steam
Piping

Steam

Head

INSTALLATION 

PLUMBING 

All plumbing shall be performed by a qualified licensed 

plumber and in accordance with applicable National and 

local codes. 

1. Use unions on all pipe connections.

2. Use only brass piping or rigid copper tubing as permitted

by codes. 

3. DO NOT use black, galvanized, PVC pipe or PEX except

as noted below. 

  Water supply and steam piping must be flushed 

to remove flux and other debris prior to connecting the 

steam generator. Failure to flush the steam piping may result

in flux poisoning or a hazardous condition. Failure to flush 

the steam piping may result in blockage or an inoperable

system.  

WATER SUPPLY (3

8" NPT) 

1. Connect to cold water line. 

  Water feed line may be flexible copper tubing, 

braided hose, PVC or PEX if permissible by local codes. 

2. Provide a shut off valve in the water supply line upstream

of the steambath generator.

3. DO NOT overheat inlet solenoid valve with solder

connections. Overheating will damage parts.

4. Flush inlet water line thoroughly before making

connection to unit.

5. Strainer recommended upstream of feed water

connection.

6. In order to reduce operating noise, reducing feed water

pres-sure to between 15 - 20 psi is recommended.

Optional pres-sure reducing valve part number 104198.

7. Provide anti-water hammer device as required.

8. Install an approved backflow preventer as required by

local codes.

DRAIN (1

2" NPT) 

  The drain from the generator should not share an 

undersink trap, unless the generator is mounted higher than 

the sink to prevent damage to the generator if the drain 

backs up. 

  A drain valve is provided to facilitate servicing. 

Provide a drain line connection from steambath generator 

drain valve according to National and local Codes. Check 

local plumb-ing code for receptor, trap and vent 

requirements. Do not connect Drain line and Safety Valve 

line together. 

Unit drains by gravity.

 

  Do not plumb the generator drain and 

condensation pan drain together in such a way that will 

cause drain water to back into condensation pan. 

DO NOT drain into a steam enclosure or any location where 

accidental contact with drain water may occur. 

In the event of a power failure the AutoFlush System valve 

will open and may discharge boiling water causing a scalding 

hazard. 

  DO NOT connect the drain valve to the steam 

piping 

AROMASTEAM 

If the optional AromaSteam Electronic Oil Delivery System 

(PN: MS AROMA) is to be installed, a 90 degree T plumbing 

fitting must be installed at a designated location on the 

steam piping. See the MrSteam AromaSteam Operation and 

Instruction Manual (PN: 100402) for installation information 

before the steam piping is installed at the technical 

downloads section of www.mrsteam.com 

 

STEAM PIPING (1

2" NPT) 

1. DO NOT install any valve in steam piping. Flow of steam

must be unobstructed. 

2. Use 1/2-inch brass pipe or copper tubing from unit to

steam head as permitted by codes. 

3. Insulate steam piping with fiberglass pipe insulation or 

similar insulation rated 212° F or higher. 

4. Pitch steam piping1/4" per foot towards steam head or

steam generator to avoid valleys and trapping of 

condensate. 

  Failure to pitch the steam piping as required for 

condensate to drain, may cause condensate to block the 

flow of steam. Blocking the steam flow may cause steam 

pressure to discharge boiling water through the steamhead, 

resulting in a scalding hazard. Blocking the flow of steam 

may cause steam to discharge through the safety valve, 

resulting in a scalding hazard. 

  A 1.5" hole in the steam room is required to 

mount the steamhead. For Linear steamhead, please refer to 

the installation instructions. 

SAFETY VALVE (3

4" NPT) 

Where permitted by local codes, provide an outlet plumbing 

connection for safety valve. 

 

  To insure proper and automatic safety valve 

operation: DO NOT connect a shut off valve or a plug at 

safety valve outlet. DO NOT connect a shut off valve or any 

obstruction in steam supply pipe. DO NOT connect the 

safety-valve output into the steam piping. 

CONDENSATION PAN 

MrSteam strongly recommends the use of a condensation 

pan in the unlikely event of a plumbing leak. Check local 

plumbing codes for receptor, trap and vent requirements. 

Condensation pans drain by gravity. The condensation pan is 

equipped with an integral 3/4" fitting. See page 17 for 

additional condensation pan installation information. 

 

  Do not plumb the generator drain and conden-

sation pan drain together in such a way that will cause drain 

water to back into condensation pan.

ns.

Steam

Generator

Steam

Generator

Steam

Generator

Steam

Generator

Steam

Generator

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam
Piping

Steam

Head

Steam

Generator

Steam
Piping

Steam

Head

All drawings are for illustrative purposes only

8

Summary of Contents for MS-150E

Page 1: ...Inc Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models MS90E MS400E and MSSUPER1E 3E ____________________ IMPORTANT Leave this material with the home owner __...

Page 2: ......

Page 3: ...ur body s reaction The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of provid ing a safe environment for steam room users The peel and...

Page 4: ...team Generator Dimensions 10 Electrical Specifications Field Power Wiring 11 Wiring Diagrams 12 13 Optional Tandem Cable Diagram 13 Initial Start Up Checkout 14 Optional Accessary Equipment 14 Trouble...

Page 5: ...AT I O N C H A RT Amps for Wire Total Adj Water Usage Shipping Model No KW 240v 1PH Size Room Vol Gallons Dimensions Wt lbs MS90E 5 21 10 0 67 14 L x 14 H x 6 D MS150E 6 25 8 0 80 14 L x 14 H x 6 D MS...

Page 6: ...m the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are correct for the incoming line voltage 2 Insure steambath generat...

Page 7: ...on only to prevent damage to the generator IMPORTANT NOTES Items 8 12 8 Install anti water hammer device as necessary 9 Provide a minimum of 12 inches at both ends and top of the steam generator or as...

Page 8: ...Installation information iSteam AirTempo or iTempo Plus Control Refer to Control Installation Manual for installation information Field installed water supply line The control features an integral tem...

Page 9: ...nock outs as shown in diagram Connect each end to the printed circuit board con nector labeled TANDEM as shown 5 Prevent the interconnecting cable from contacting hot surfaces such as steam outlet saf...

Page 10: ...ain valve is provided to facilitate servicing Provide a drain line connection from steambath generator drain valve according to National and local Codes Check local plumb ing code for receptor trap an...

Page 11: ...mark on the nipple where the surface of the wall is Remove the nipple and measure the portion that was in the wall the end to your mark Subtract 1 4 from that dimension and select a brass nipple of th...

Page 12: ...VALVE 3 4 NPT MANUAL DRAIN VALVE 1 2 NPT AUTOFLUSH VALVE 1 2 NPT 1 M Optional AutoFlush 2 All units in inches MM J Water Inlet Control Accessory Connections Steam Outlet Safety Valve Optional AutoFlus...

Page 13: ...or or one that is capable of being locked in the open position 5 For single phase units use two wire supply source and equipment grounding wire Neutral white wire is not required ELECTRICAL CHART ____...

Page 14: ...RD TRANSFORMER POWER INPUT GROUND WATER FEED SOLENOID VALVE FUSES HEATER THERMOSTAT EXPRESS STEAM optional AutoFlush optional HomeWizard iGenie optional iSteam AirTempo iTempo iTempoPlus Control CONTA...

Page 15: ...provided PN 103904 through the knock outs as shown in the Diagram on page 7 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring...

Page 16: ...access panel for inspection INITIAL START UP AND CHECKOUT 1 Turn on control Follow specific instructions provided with controls 2 Steam will begin to appear in approximately 5 minutes unless equipped...

Page 17: ...s LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators ______________________________________________________________________________________________________________________________________ GREEN...

Page 18: ...e must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown 5 The AutoFlush valve must be installed within the orientation range shown DO NOT...

Page 19: ...ble national and local codes Check local plumbing code for receptor trap and vent requirements Condensation pans drain by gravity The condensation pan is equipped with an integral female 3 4 NPT fitti...

Page 20: ...STRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity DO NOT use for wiring repair or other purposes not related to component identification MS SUPER MODELS MSSUPE1E MSSUPER3E w...

Page 21: ...1E MSSUPER2E MSSUPER2E MSSUPER3E MSSUPER3E Drain Valve Safety Valve 15PSI Water Feed Solenoid Valve w filter Transformer 24VAC Liquid Level Control Board Tandem Cable for 2 generators 12 ft Tandem Cab...

Page 22: ...d affix this warning sticker in a conspicuous location may result in serious injury or death Install the iSteam AirTempo iTempo or iTempo Plus controls according to installation instructions Failure t...

Page 23: ...SAVETHESEINSTRUCTIONS The manual supplied with the generator includes a peel and stick warning label Its proper use is an essential part of providing a safe environ ment for steam room users The peel...

Page 24: ...temperature according to personal preference however it is highly rec ommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels Set duration to a maximum of 10 m...

Page 25: ...they can be irritants Use essential oils with caution 2 Place the drops into the MrSteam AromaSteam steamhead recess prior to turning on the steambath DO NOT place drops in a hot steam head as serous...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...ration I MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy CT Day Spa Digital 1 Express Steam Feel...

Reviews: