Force-Air Propane Construction Heater
Operating Instructions and Owner’s Manual
6
Ifanyoriginalwiringassuppliedbytheheatermustbereplaced,
itmustbereplacedwithtypeAWG105°Cwireoritsequivalent
exceptasindicated(*typeSF2-200,**SGI250°C).
170QFAVT ‑ WIRING CHART
COLOR
LENGTH
FROM
TO
White
7”
Valve
TerminalBlock
Black
6”
On/OffSwitch
TerminalBlock
Red-(Hi-Temp)
161/2”
HighLimitSwitch
Valve
Red-(Hi-Temp)
161/2”
HighLimitSwitch
TerminalBlock
Orange
11”
FlameControl
SparkPlug
(Ignition)
Green
7”
FlameControl
Ground
(Harness)
Red
7”
FlameControl
TerminalBlock
(Harness)
White
6”
FlameControl
TerminalBlock
(Harness)
Black
6”
FlameControl
TerminalBlock
(Harness)
HOW MUCH HEAT DO I REQUIRE?
Foreconomy,itisimportanttomatchinputtothatrequired.But
heatrequirementsoftenvary.Forexample,itusuallytakesalot
moreheattogetthingswarmthanitdoestokeepthemthatway.
Likewise,outsideairtemperatureusuallychangesduringtheday
soyoumayneedmoreheatatnightthanyoudointhedaytime.
Anapproximationoftheheatrequiredcanbefoundbyusingthe
chartbelow.
Recommended Minimum Gauge
for Cord Extensions
Wire Gauge Chart A.W.G.
Name
Plate 120V
Cord Length in Feet
Amps.
25
50
100
150
5-6
18
16
14
12
6-8
18
16
12
10
8-12
18
14
12
10
10-12
16
14
10
8
12-14
16
12
10
8
WARNING:
Whenusingathermostatcontrolledheater,
its exit area should be protected from personnel and
warningspostedofsuddenstartup.
Cubic feet
Temperature Rise Required (
o
F)*
of space to
be heated
20
o
30
o
40
o
50
o
5,000
14,000
20,000
27,999
34,000
7,000
19,000
28,000
38,000
47,000
10,000
27,000
40,000
54,000
67,000
15,000
40,000
60,000
80,000100,000
20,000
54,000
80,000107,000133,000
30.000
80,000120,000160,000200,000
50,000133,000200,000266,000333,000
BTU’S PER HOUR REQUIRED
HIGH-LIMIT SWITCH
X2
LINE
VALVE
NEUT
GRD
CHASSIS
GROUND
CHASSIS
GROUND
CHASSIS
GROUND
CHASSIS
GROUND
CHASSIS
GROUND
LINECORD
THERMOSTAT
MOTO
R
GAS
VALVE
FLAMECONTROL
SPARKPLUG
G
W
G
G
B
B
B
B
R
W
W
R
Y
B
Y
G
G
WIRING
DIAGRAM
SIZE AND CAPACITY OF PROPANE
CYLINDERS
Thechartsbelowshowtheapproximatesizeofthecylinder
requiredfortheseheaters.Tousethechart:
1. Selectthelowestairtemperatureexpected(atthebottomof
thechart).
2. Movestraightuptotimeofoperationdesired
(leftsideofthechart).
3. Readthecylindersizerequired.
Allheatersshouldhave:
fullcylinders
goodaircirculation
nofrostoncylinders
FuelCyclinderCapacity:100#
COLORCODE
B-BLACK
L-BLUE
G-GREEN
O-ORANGE
R-RED
W-WHITE
1 cylinder
2 cylinders
3 cylinders
Y
-
YELLOW