Force-Air Propane Construction Heater
Operating Instructions and Owner’s Manual
4
FUEL GAS ODOR
LP gas and natural gas have man‑made odorants added
specifically for detection of fuel gas leaks.
If a gas leak occurs you should be able to smell the fuel
gas. Since Propane (LP) is heavier than air you should
smell for the gas odor low to the floor.
ANY GAS ODOR
IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!
•
Donottakeanyactionthatcouldignitethefuelgas.Do
notoperateanyelectricalswitches.Donotpullanypower
supplyorextensioncords.Donotlightmatchesoranyother
sourceofflame.Donotuseyourtelephone.
•
Geteveryoneoutofthebuildingandawayfromthearea
immediately.
•
Closeallpropane(LP)gastankorcylinderfuelsupplyvalves,
orthemainfuelsupplyvalvelocatedatthemeterifyouuse
naturalgas.
•
Propane(LP)gasisheavierthanairandmaysettleinlow
areas.Whenyouhavereasontosuspectapropaneleak,keep
outofalllowareas.
•
Useyourneighbor’sphoneandcallyourfuelgassupplierand
yourfiredepartment.Donotre-enterthebuildingorarea.
•
Stayoutofthebuildingandawayfromtheareauntildeclared
safebythefirefightersandyourfuelgassupplier.
•
FINALLY,letthefuelgasservicepersonandthefirefighters
checkforescapedgas.Havethemairoutthebuildingand
areabeforeyoureturn.Properlytrainedservicepeoplemust
repairanyleaks,checkforfurtherleakages,andthenrelight
theapplianceforyou.
ODOR FADING - NO ODOR DETECTED
•
Somepeoplecannotsmellwell.Somepeoplecannotsmell
theodoroftheman-madechemicaladdedtopropane(LP)or
naturalgas.Youmustdetermineifyoucansmelltheodorant
inthesefuelgases.
•
Learntorecognizetheodorofpropane(LP)gasandnatural
gas.Localpropane(LP)gasdealerswillbemorethanhappy
togiveyouascratchandsniffpamphlet.Useittobecome
familiarwiththefuelgasodor.
•
Smokingcandecreaseyourabilitytosmell.Beingaround
anodorforaperiodoftimecanaffectyoursensitivityto
thatparticularodor.Odorspresentinanimalconfinement
buildingscanmaskfuelgasodor.
ODOR FADE WARNING
WARNING
Asphyxiation Hazard
•Donotusethisheaterforheatinghumanlivingquarters.
•Donotuseinunventilatedareas.
•Theflowofcombustionandventilationairmustnotbeobstructed.
•Properventilationairmustbeprovidedtosupportthecombustionairrequirementsoftheheaterbeingused.
•Refertothespecificationsectionoftheheater’smanual,heaterdataplate,orcontacttheFactorytodeterminecombustionair
ventilationrequirementsoftheheater.
•Lackofproperventilationairwillleadtoimpropercombustion.
•Impropercombustioncanleadtocarbonmonoxidepoisoningleadingtoseriousinjuryordeath.Symptomofcarbonmonoxide
poisoningcanincludeheadachesdizzinessanddifficultyinbreathing.
•
The odorant in propane (LP) gas and natural gas is
colorless and the intensity of its odor can fade under
some circumstances.
•
Ifthereisanundergroundleak,themovementofgas
throughthesoilcanfiltertheodorant.
•
Propane(LP)gasodormaydifferinintensityatdifferent
levels.SincePropane(LP)gasisheavierthanair,theremay
bemoreodoratlowerlevels.
• Always be sensitive to the slightest gas odor.
Ifyou
continuetodetectanygasodor,nomatterhowsmall,treat
itasaseriousleak.Immediatelygointoactionasdiscussed
previously.
ATTENTION ‑ CRITICAL POINTS TO
REMEMBER!
•
Propane (LP) gas has a distinctive odor. Learn to
recognize these odors. (Reference Fuel Gas Odor and
Odor Fading sections above.
•
EvenIfyouarenotproperlytrainedintheserviceandrepair
oftheheater,ALWAYSbeconsciouslyawareoftheodorsof
propane(LP)gasandnaturalgas.
•
Ifyouhavenotbeenproperlytrainedinrepairandservice
ofpropane(LP)gasthendonotattempttolightheater,
performserviceorrepairs,ormakeanyadjustmentstothe
heateronthepropane(LP)gasfuelsystem.
•
Aperiodicsnifftestaroundtheheaterorattheheater’s
joints;i.e.hose,connections,etc.,isagoodsafetypractice
underanyconditions.Ifyousmellevenasmallamountof
gas,CONTACTYOURFUELGASSUPPLIERIMMEDIATELY.DO
NOTWAIT!
Heater Elevation Adjustment
Thisheaterisequippedwithanelevationadjustmentpanellocated
attheexhaustendofthecontrolbox.
1.
Donotadjusttheheatercombustiontubeelevationwhile
heaterisrunningorhot.Adjustmentstoelevationshouldonly
bemadeaftertheheaterhascooledtotouch.
2. Toadjusttheheatercombustiontubeelevation,turnthe
adjustmentscrewknobcounterclockwiseandliftthe
combustiontubetodesiredposition.