Forced Air Propane Construction Heater

Operating Instructions and Owner’s Manual

Maintenance and stOrage

1.  The heater should be inspected before each use, and at least 

annually by a qualified person.

2.  Before each use, check the soft "O" ring seat at the bullnose 

of the POL fitting. If the "O" ring is cut, scuffed, or otherwise 
damaged, replace it with part number F273786.

3.  Turn off the gas at the LP-gas supply cylinder(s) when the heater 

is not in use.

4.  When the heater is to be stored indoors, the connection 

between the LP-gas supply cylinder(s) and the heater must 
be disconnected and the cylinder(s) removed from the heater 
and stored out of doors and in accordance with Chapter 5 of 
the standard for Storage and Handling of Liquefied Petroleum 
Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane 
Installation Code.

5.    It is recommended that the internal battery be maintained on a 

constant charge by leaving it plugged into a 120V power source.

6.    The heater may be stored with the charger disconnected if all of 

the following conditions are met.

       •The battery is fully charged before storing. (Failure to store fully 

charged will shorten battery life.)

       •The average temperature of the storage location is below 50° 

(10°C).

       •Storage duration is less than 6 months.

serVicing

A hazardous condition may result if a heater is used that has been 
modified or is not functioning properly. When the heater is working 
properly:

The flame is contained within the heater.

*   The flame is essentially blue with perhaps some yellow tipping.

There is no strong disagreeable odor, eye burning or other 
physical discomfort.

There is no smoke or soot internal or external to the heater.

There are no unplanned or unexplained shut downs of the 
heater.

The parts lists and exploded view show the heater as it was 
constructed. Do not use a heater which is different from that shown. 
In this regard, use only the hose, regulator and cylinder connection 
fitting (called a POL fitting) supplied with the heater. 

iMpOrtant

 

Match the color stripe on the hangtag attached to the hose assembly 
with the color on the label located near the propane inlet fitting on 
the heater. Do not use alternates. For this heater, the regulator must 
be set as shown in "specifications". If there is any uncertainty about 
the regulator setting, have it checked.

A heater which is 

not 

working right must be repaired, but 

only

 by a 

trained, experienced service person.

In-warranty products will be repaired with no charge for either parts 
or labor. Please include a brief statement indicating date, place of 
purchase, the nature of the problem and proof of purchase.

Out-of-warrranty products will be repaired with a charge for parts, 
labor and shipping.

WARNING 

FIRE HAZARD—ALWAYS DISCONNECT THE HEATER FROM 
THE POWER SUPPLY (WALL OUTLET) BEFORE REMOVING 
THE POWER CORD FROM THE HEATER.  UNDER CERTAIN 
CONDITIONS, WITH THE HEATER PLUGGED INTO THE POWER 
SUPPLY, THE EXPOSED CONNECTOR CAN BE SHORTED BY 
FOREIGN MATERIAL AND MAY CAUSE A FIRE.  FOREIGN 
MATERIALS OF A CONDUCTIVE NATURE, SUCH AS, BUT NOT 
LIMITED TO, STEEL WOOL, ALUMINUM FOIL, OR ANY BUILD-
UP OF METALLIC PARTICLES, SHOULD BE KEPT FROM THE 
CONNECTOR.  ALWAYS UNPLUG HEATER BEFORE ATTEMPTING 

To CleAN.

Heater OperatiOn

START

1.   The HERO heater is equipped with a blower fan switch, located 

on the control panel of the heater.  Press the on/off switch to 
start the blower fan.  Once the fan has been turned on, the 
green LED light on the control panel will turn on solid, indicating 
that the fan is operating. The blower fan must be turned on 
before the gas/igniter valve is SLOWLY pressed to light the 
heater.

CAUTION: Failure to start the fan prior to gas ignition may 

damage the heater.  always confirm that the fan is 
operating before igniting the heater. 

2.  Open propane supply valve on propane tank slowly.  Note:  If not 

opened slowly, excess-flow check valve on propane tank will stop 
gas flow.  If this happens, close propane supply valve and open 
again slowly.  Wait 15 seconds before Step 3.

3.  After the blower fan has been started, SLOWLY depress the 

orange gas/igniter valve button located on the control panel to 
ignite the heater.  Keep the valve depressed for 30-60 seconds, 
after burner lights, then release and the heater will continue to 
operate. If the burner does not light, wait 15 seconds, repeat this 
step until burner ignites.

 

WARNING:

  Be sure motor and fan are running before pushing 

in gas/igniter valve button.  Flames could flash outside heater or 
internal damage to heater may result if motor and fan are not 
running.

saFetY sHut dOwn Feature

When the heater detects a power source change (connect or 
disconnect AC power while operating) it will automatically shut down.  
After shut down, the "START" procedure will have to be used to
restart the heater.

STOP

1.   Press the on/off switch to turn off the heater.

2.  Turn off gas supply when heater is not in use.

Summary of Contents for HEATSTAR HS35CLP

Page 1: ...rea in which it is used Adequate combustion and ventilation air must be provided Refer to page E 3 READ INSTRUCTIONS CAREFULLY Read and follow all instructions Place instructions in a safe place for f...

Page 2: ...TAIN CARBON MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE WARNING YOUR SAFETY IS IM...

Page 3: ...he heater thoroughly for damage DO NOT operate a damaged heater 2 DO NOT modify the heater or operate a heater which has been modified from its original condition 3 Use only propane gas 4 Use only VAP...

Page 4: ...son and the firefighters check for escaped gas Have them air out the building and area before you return Properly trained service people must repair any leaks check for further leakages and then relig...

Page 5: ...ed battery 6 The heater is designed to operate and charge the battery at the same time when plugged into a 120V outlet 7 Mr Heater recommends continuously charging the battery between heater uses for...

Page 6: ...is not working right must be repaired but only by a trained experienced service person In warranty products will be repaired with no charge for either parts or labor Please include a brief statement i...

Page 7: ...ter Replace damaged cords immediately Use only Mr Heater original battery type Do not dispose of the batteries in a fire The cell may explode See Battery Recycling Information below Do not open or mut...

Page 8: ...gas main 1 36 27930 board led off switch 35k 1 27953 power supply cord 1 27954 battery connection wiring harness 1 27956 hose and regulator assembly 1 Not shown on exploded view re F ite M descripti...

Page 9: ...es are available if required With the cooperation of independent dealers a nationwide network of authorized servicing dealers is available for your servicing requirements Should your product require s...

Page 10: ...sponsibility of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a particular purpose and there is no warranty of merchantability In no eve...

Page 11: ...E 11 Forced Air Propane Construction Heater Operating Instructions and Owner s Manual...

Page 12: ...nistro de gas al artefacto El mantenimiento debe realizarlo una agencia de servicios calificada Este calefactor port til a gas no tiene una fuente propia de ventilaci n Utiliza el aire ox geno del rea...

Page 13: ...CCIONES ETIQUETAS ETC P NGASE EN CONTACTO CON EL FABRICANTE ADVERTENCIA PELIGRO DE INCENDIO QUEMADURAS INHALACI N Y EXPLOSI N MANTENGA LOS COMBUSTIBLES S LIDOS COMO MATERIALES DE CONSTRUCCI N PAPEL O...

Page 14: ...NO opere un calentador da ado 2 NO modifique el calentador ni opere un calentador cuya configuraci n original haya sido modificada 3 Utilice nicamente gas propano 4 Utilice nicamente suministro de pro...

Page 15: ...O permita que la persona del servicio de gas y los bomberos revisen si hay fugas de gas Haga que ventilen el edificio y el rea antes de su regreso Un agente de servicios calificado debe reparar cualqu...

Page 16: ...tador est dise ado para funcionar y recargar la bater a al mismo tiempo cuando est conectado a un tomacorriente de 120V 7 Mr Heater recomienda recargar la bater a sistem ticamente entre uso y uso del...

Page 17: ...tado y experimentado Para los productos en garant a la reparaci n se realizar sin costos de piezas ni mano de obra Por favor incluya una breve declaraci n indicando la fecha y lugar de compra la natur...

Page 18: ...ue aparece a continuaci n No abra ni mutile las bater as El electrolito que se libera es corrosivo y podr a da ar sus ojos o su piel Puede resultar t xico si se ingiere Ponga cuidado al manipular las...

Page 19: ...27935 interruptor l mite m ximo 1 35 27932 v lvula gas principal 1 36 27930 panel led interruptor apagado 35k 1 27953 cable alimentaci n de el ctrica 1 27954 mazodecablesdeconexi ndelabater a 1 27956...

Page 20: ...sici n Con la cooperaci n de agentes independientes se encuentra disponible en todo el pa s una red de proveedores de servicios de reparaci n autorizados para atender sus necesidades de reparaci n Si...

Page 21: ...ien adquiri nuestro producto Lo anterior describe las responsabilidades de la Compa a en toda su extensi n No hay otras garant as ni expl citas ni impl citas Espec ficamente no hay garant as acerca de...

Page 22: ......

Page 23: ...areil L entretien doit tre effectu par un fournisseur de services d entretien qualifi Cet appareil de chauffage portatif aliment au gaz n est pas ventil Il utilise l oxyg ne de l air ambiant Une circu...

Page 24: ...INCENDIE D INHALATION ET D EXPLOSION GARDEZ LES COMBUSTIBLES SOLIDES TELS QUE LES MAT RIAUX DE CONSTRUCTION LE PAPIER ET LE CARTON UNE DISTANCE S CURITAIRE DE L APPAREIL DE CHAUFFAGE TEL QUE RECOMMAND...

Page 25: ...areil de chauffage et ne le faites pas fonctionner s il n est plus dans son tat d origine 3 Utilisez uniquement du gaz propane 4 Utilisez uniquement une alimentation au propane LIMINATION DES MANATION...

Page 26: ...comporte aucun risque EN DERNIER LIEU laissez le personnel du service des incendies ou d approvisionnement en gaz combustible v rifier si du gaz s chappe Assurez vous qu ils aient a r l immeuble avan...

Page 27: ...es pour charger une batterie qui est enti rement plat 6 L appareil de chauffage est con u pour fonctionner et charger la batterie simultan ment lorsqu il est branch dans une prise de courant de 120V 7...

Page 28: ...br ve description indiquant la date l endroit o l achat a t effectu la nature du probl me et la preuve de l achat Les produits qui ne sont pas couvert sous cette garantie seront r par s mais des frais...

Page 29: ...exploser Voir ci dessous Information pour le recyclage de batteries N ouvrez pas ou ne mutilez pas la batterie Les lectrolytes rel ch s sont corrosifs et peuvent causer des blessures aux yeux et la p...

Page 30: ...que 35 k 1 34 27935 interrupteur sup rieur limite 1 35 27932 robinet gaz principal 1 36 27930 panneau del arr t interrupteur 35 k 1 27953 cordon d alimentation lectrique 1 27954 faisceaudec blespourco...

Page 31: ...troite collaboration avec un r seau national de d taillants ind pendants qui sont galement votre disposition pour r pondre vos besoins en mati re de r paration Si ce produit n cessite des r parations...

Page 32: ...n existe aucune autre garantie expresse ou tacite Plus pr cis ment il n y a aucune garantie concernant l ad quation une utilisation particuli re ni aucune garantie concernant la qualit marchande En a...