background image

2

Enerco Group, Inc. |convection construction Heater

operating Instructions and owner’s Manual

70486 Rev. D 04/08

gENERAl HAZARd wARNINg:

 FAILURE To coMPLY WITH THE PREcAUTIonS AnD 

InSTRUcTIonS PRoVIDED WITH THIS HEATER, cAn 
RESULT In DEATH, SERIoUS BoDILY InJURY AnD 
PRoPERTY LoSS oR DAMAGE FRoM HAZARDS oF FIRE, 
EXPLoSIon, BURn, ASPHYXIATIon, cARBon MonoX-
IDE PoISonInG, AnD/oR ELEcTRIcAL SHocK.

 onLY PERSonS WHo cAn UnDERSTAnD AnD FoLLoW 

THE InSTRUcTIonS SHoULD USE oR SERVIcE THIS 
HEATER.

 IF YoU nEED ASSISTAncE oR HEATER InFoRMATIon 

SUcH AS An InSTRUcTIonS MAnUAL, LABELS, ETc. 
conTAcT THE MAnUFAcTURER.

wARNINg: 

 noT FoR HoME oR REcREATIonAL VEHIcLE USE

wARNINg: 

 FIRE, BURn, InHALATIon, AnD EXPLoSIon HAZARD. 

KEEP SoLID coMBUSTIBLES, SUcH AS BUILDInG 
MATERIALS, PAPER oR cARDBoARD, A SAFE DISTAncE 
AWAY FRoM THE HEATER AS REcoMMEnDED BY THE 
InSTRUcTIonS nEVER USE THE HEATER In SPAcES 
WHIcH Do oR MAY conTAIn VoLATILE oR AIRBoRnE 
coMBUSTIBLES, oR PRoDUcTS SUcH AS GASoLInE, 
SoLVEnTS, PAInT THInnER, DUST PARTIcLES oR Un-
KnoWn cHEMIcALS.

THE STATE OF CAlIFORNIA REQUIRES THE  
FOllOwINg wARNINg:

wARNINg:

 COMbuSTION by-prODuCTS prODuCED WHEN uS-

InG THIS PRoDUcT conTAIn cARBon MonoXIDE, 
A cHEMIcAL KnoWn To THE STATE oF cALIFoRnIA 
TO CAuSE CANCEr AND bIrTH DEfECTS (Or OTHEr 
rEprODuCTIVE HArM).

wARNINg:

 YoUR SAFETY IS IMPoRTAnT To YoU AnD To oTHERS, 

So PLEASE READ THESE InSTRUcTIonS BEFoRE YoU 
oPERATE THIS HEATER.

TABlE OF CONTENTS

HEATER SPEcIFIcATIonS ............................................................ 2

WARnInGS ................................................................................ 2

oPERATInG PREcAUTIonS ........................................................ 3

SAFETY PREcAUTIonS ............................................................... 3

oDoR FADE WARnInG .............................................................. 4

cAUTIon: SHELL EXTEnSIon InSTRUcTIonS. ........................... 5

oPERATInG InSTRUcTIonS ....................................................... 6

SERVIcInG ................................................................................. 6

SIZE AnD cAPAcITY oF PRoPAnE cYLInDERS REQUIRED .......... 7

80CV - pArTS ............................................................................. 8

200CV - pArTS ........................................................................... 9

WARRAnTY ..............................................................................12

InSTRUcTIonS FoR oRDERInG PARTS  .....................................12

SpECIFICATIONS

Type of Gas:........For use with Propane only

Gas Supply  
Pressure 
to regulator ........Max.: bottle pressure .......Min.: 80cV
 

 

= 5 psig (34.5 kpa) 

 

 

Min.: 200CV 

 

 

= 15 psig (103 kpa)

regulator out ......80cV ...............................200CV
 

 = 11" W.C. (2.74 kpa)      = 10 psig (68.9 kpa)

Ignition: ..............Piezo Ignitor

Minimum  
Ambient 
Temp. Rating ......0°f (-17.8°C)

Model: ...............80CV ...............................200CV 

Rating: ................30,000-80,000 btu/hr  .....75,000-200,000 btu/hr
 

(8.79 - 23.4 kW) 

(22.0 - 58.6 kW)

Fuel  
consumption: .....1.4 to 3.7 #/hr .................3.5 - 9.3 #/hr 
 

(.74 – 1.80 kg/hr) 

(1.44 - 4.32 kg/hr)

Fuel orifice 
Port no.: .............6 .....................................6 

 

Fuel orifice 
Port Size: ............0.0472"  ...........................0.0320"
 

(1.20mm) 

(.813mm) 

 

 

 

 

 

 

Summary of Contents for HeatStar HS200CV

Page 1: ...ty damage personal injury or loss of life WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use...

Page 2: ...LS THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING WARNING Combustion by products produced when us ing this product contain carbon monoxide a chemical known to the State of California to cause...

Page 3: ...3 DO NOT light or operate heater unless the shells are fully extended and locked into position See enclosed assembly sheet for instructions 4 Use only propane gas 5 Use only VAPOR WITHDRAWAL propane s...

Page 4: ...s service person and the firefighters check for escaped gas Have them air out the building and area before you return Properly trained service people must repair any leaks check for further leakages a...

Page 5: ...L WHEN THIS HAPPENS THE SCREW HOLES WILL LINE UP STEP 4 LOCK THE CLIP INTO PLACE WITH 3 SCREWS AS SHOWN THE HEATER MUST NOT BE OPERATED UNLESS THE OUTER SHELL IS PROPERLY EXTENDED AND FULLY LOCKED INT...

Page 6: ...s been modified or is not functioning properly When the heater is working properly The flame is contained within the heater The flame is essentially blue with perhaps some yellow tipping There is no s...

Page 7: ...ow the approximate size of the cylinder required for these heaters To use the chart 1 Select the lowest air temperature expected at the bottom of the chart 2 Move straight up to time of operation desi...

Page 8: ...8 Enerco Group Inc Convection Construction Heater Operating Instructions and Owner s Manual 70486 Rev D 04 08...

Page 9: ...9 Operating Instructions and Owner s Manual Enerco Group Inc Convection Construction Heater 70486 Rev D 04 08...

Page 10: ...purchased our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a particul...

Page 11: ...ilit totale de l entreprise Il n existe aucune autre garantie expresse ou tacite Plus pr cis ment il n y a aucune garantie concernant l ad quation une utilisation particuli re ni aucune garantie conce...

Page 12: ...9 Enerco Group Inc Appareil de chauffage convection pour chantier de construction Guide d utilisation et instructions de fonctionnement Version 04 08 L2 n 70486...

Page 13: ...8 Enerco Group Inc Appareil de chauffage convection pour chantier de construction Guide d utilisation et instructions de fonctionnement Version 04 08 L2 n 70486...

Page 14: ...nbonne de gaz requise pour ces appareils de chauffage Pour utiliser le tableau 1 S lectionnez la temp rature de l air la plus basse pr vue au bas du tableau 2 Allez ensuite directement au haut du tabl...

Page 15: ...FICATION Un appareil de chauffage qui a t modifi ou qui ne fonctionne pas correctement risque d tre une cause de dangers La flamme reste dans l appareil de chauffage La flamme a une teinte bleue avec...

Page 16: ...EVRAIENT TRE ALIGN S TAPE 4 VERROUILLEZ LES CLIPS AU MOYEN DES TROIS VIS TEL QU ILLUSTR L APPAREIL NE DOIT PAS FONCTIONNER MOINS QUE LES COQUES EXT RIEURES SOIENT COMPL TEMENT OUVERTES ET VERROUILL ES...

Page 17: ...oit ne comporte aucun risque EN DERNIER LIEU laissez le personnel du service des incendies ou d approvisionnement en gaz combustible v rifier si du gaz s chappe Assurez vous qu ils aient a r l immeubl...

Page 18: ...LUMEZ PAS l appareil et ne le faites pas fonctionner moins que la coque soit compl tement ouverte et verrouill e en position Consultez la feuille d assemblage pour obtenir les instructions 4 Utilisez...

Page 19: ...S CHIMIQUES INCONNUS L TAT DE LA CALIFORNIE IMPOSE L AVERTISSEMENT SUIVANT AVERTISSEMENT L UTILISATION DE CET APPAREIL CR E DES SOUS PRODUITS DE COMBUSTION CONTENANT DU MON OXYDE DE CARBONE UN PRODUIT...

Page 20: ...tra nant des dommages mat riels ou des blessures graves voire mortelles N entreposez ni n utilisez d essence ou autres liquides ou vapeurs inflammables proximit de ce type d appareil Aucune bonbonne d...