8
Basecamp, Inc. | Portable Shower
Operating Instructions and OwnerÊs Manual
TROUBLESHOOTING
PROBLEM
SOLUTION
Water will not flow
from shower head
Check that pump debris filter is not clogged
Check that appliance is switched on
Check sufficient water is available
Check that the pump is connected to the appliance
Make sure the battery is charged
Check for kinks in shower hose
Check that pump fuse is not blown
Check that the shower head ON/OFF switch is in the open position
Burner will
not light
Check that there is gas in cylinder
Check that the water is flowing from shower head
Check that water is not over temperature
Check that battery does not require re-charging
Check the Flow Switch on shower head make sure it is fully open
Water is not
hot enough
Check gas control
Check source water temperature (water temps below 50
°
F might require recirculation)
Cycle the water through the system back in to the source reservoir then through the appliance again
Reduce flow using the flow valve
LED DIAGNOSTIC
E0
Inlet Temperature Sensor Failure
E1
Flame Sensor Error
E2
Water Flow Error
E3
Unsuccessful Ignition/Flame Out
E4
Outlet Temperature Sensor Fault
E6
Back Up Water Temperature High Limit Fault
(131
°F, 55° C)
E7
Primary Water Temperature High Limit Switch Fault
(122
°
F, 50
°
C)