background image

8

Basecamp, Inc. | Portable Shower

Operating Instructions and OwnerÊs Manual

TROUBLESHOOTING

PROBLEM

SOLUTION

Water will not flow
 from shower head

Check that pump debris filter is not clogged

Check that appliance is switched on

Check sufficient water is available

Check that the pump is connected to the appliance

Make sure the battery is charged

Check for kinks in shower hose 

Check that pump fuse is not blown

Check that the shower head  ON/OFF switch is in the open position

Burner will

not light

Check that there is gas in cylinder

Check that the water is flowing from shower head

Check that water is not over temperature

Check that battery does not require re-charging

Check the Flow Switch on shower head make sure it is fully open 

Water is not

hot enough

Check gas control

Check source water temperature (water temps below 50

°

F might require recirculation)

Cycle the water through the system back in to the source reservoir then through the appliance again

Reduce flow using the flow valve

LED DIAGNOSTIC

E0

Inlet Temperature Sensor Failure

E1

Flame Sensor Error

E2

Water Flow Error

E3

Unsuccessful Ignition/Flame Out

E4 

Outlet Temperature Sensor Fault

E6

Back Up Water Temperature High Limit Fault 
(131

°F, 55° C)

E7

Primary Water Temperature High Limit Switch Fault 
(122

°

F, 50

°

 C)

Summary of Contents for BOSS XCW20

Page 1: ...open flame Shut off gas to appliance BATTERY OPERATED SHOWER SYSTEM Fully Portable Instant Hot Water Shower 2015 OPERATING INSTRUCTIONS AND OWNER S MANUAL READ INSTRUCTIONS CAREFULLY Read and follow a...

Page 2: ...AFETY PRECAUTIONS ARE ESSENTIAL WHEN ANY MECHANICAL OR PROPANE FUELED EQUIPMENT IS INVOLVED THESE PRECAUTIONS ARE NECESSARY WHEN USING STORING AND SERVICING FOLLOWING THESE SAFETY ALERTS WILL REDUCE T...

Page 3: ...fuel type approved for the appliance Check for gas leaks with soapy water DO NOT USE A FLAME TO CHECK FOR LEAKS CAUTION Certified for use only with LP gas cylinders of the U S Department of Transporta...

Page 4: ...re reaches 122 F 50 C Water Flow Sensor water must be flowing through the system to allow the burner to ignite In the case that the water supply is restricted or ceases the burner will be extinguished...

Page 5: ...e finished with the appliance slide the Switch to the OFF position and depress the Pump button to stop the flow of water to the appliance OPERATING FAUCET INSTRUCTIONS 1 Press the power button and onc...

Page 6: ...rs IMPORTANT If the appliance is not being used or is stored it must be recharged every three months to guarantee the battery life expectancy Failure to do so may result in battery failure STORAGE WAR...

Page 7: ...onnecting when servicing controls Wiring errors can cause improper and dangerous operation The parts lists and wiring diagram show the appliance as it was constructed Do not use a heater which is diff...

Page 8: ...that the water is flowing from shower head Check that water is not over temperature Check that battery does not require re charging Check the Flow Switch on shower head make sure it is fully open Wate...

Page 9: ...Panel 35559 1 17 Board LED 35560 1 18 Tube Gas Inlet 35561 1 19 Valve Water 35562 1 20 Probe Water Temp Outlet 35563 1 21 Tube Gas Outlet 35564 1 22 Tube Water Outlet 35565 1 23 Controller 35566 1 24...

Page 10: ...LACEMENT PARTS USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY ANSI Z21 96 2014 CSA...

Reviews: