OPERATING PRECAUTIONS
Propane is heavier than air. If propane leaks from a connection or
fitting, it sinks to the floor, collecting there with the surrounding
air, forming a potentially explosive mixture. During set up check
all connections and fittings for leaks using soapy water. Never use
flame. Bubbles indicate a leak. Check that the connection is not
cross threaded and that it is tight. Perform another leak check. If
there is still a leak, remove the cylinder and contact Mr. Heater
direct for service or repair.
•
Use for water heating only. Never alter in anyway or use with
any device or part not expressly approved by Mr. Heater.
•
This appliance is designed to be used with a source water
temperature of 60
°
°F or below
•
The maximum temperature rise from the appliances
is
35À F
to
the shower head and 42À F from the source water
temperature
.
•
For safety the appliance is designed to shut off the burner
when the water temperature from either of the outlets
reaches 122
°
F/50
°
C
•
The average run time for the XCW20 from a fully charged
battery is 30 - 40 mins before it will require recharging
•
During operation ensure that all air inlets and exhaust
(front,sides and back) are kept free from obstructions and
closure.
SAFETY FEATURES
This appliance is equipped with the following safety
features:
•
Over Temperature Sensor – the appliance will not
allow the burner to remain in operation once the outlet
water temperature reaches 122ÀF/50
°
C.
•
Water Flow Sensor – water must be flowing through
the system to allow the burner to ignite. In the case
that the water supply is restricted or ceases, the burner
will be extinguished and will not relight.
•
Tilt Switch – in the event that the appliance is tilted past 30
°
during operation the appliance will shut down until it is
located on a level surface.
CONTROL PANEL
OPERATING SHOWER INSTRUCTIONS
1.
Attach the Quick Connect Fitting for the pump on the
backside of shower unit (FIG. 1) and attach the shower
head hose Quick Connect Fitting on the front side of shower
unit (FIG. 2).
2.
Submerge the pump in a suitable reservoir of water. The pump
motor can be damaged if it is not fully submerged in water
while in use.
DO NOT use water from rivers or lakes
.
S
ediment can damage
the pump and the appliance. DO NOT use in ocean
because
salt water
can damage the pump and appliance.
WARNING: This appliance will not heat the water enough to
kill potentially dangerous microbes. DO NOT use this appliance
for potable water.
3.
Screw propane clockwise into shower unit regulator.
4.
Press the Power button, the unit will switch on and the shower
head OUTLET icon will automatically be selected on the control
panel.(FIG. 3) Make sure the shower is fully charged. Ensure
that the Switch on the shower head is in the „Open‰ position
by sliding the switch downwards. (FIG. 4)
AIR INLETS
AND
EXHAUST
PUMP INPUT
PUMP
Quick-Connect
SHOWER HEAD
Quick-Connect
Switch
ON
FIG. 1
FIG. 2
Battery Level Indicator
Outlet Indicator
System On / Off
Pump On / Off
Switch Between
Shower head
and Faucet
Output Temp Control
Water Outlet Temp
Burner “ON” Indicator
Water Inlet
Temp
Over-
Temp
Indicator
FIG. 3