background image

4

Basecamp, Inc. | Portable Shower

Operating Instructions and OwnerÊs Manual

OPERATING PRECAUTIONS

Propane is heavier than air. If propane leaks from a connection or 
fitting, it sinks to the floor, collecting there with the surrounding 
air, forming a potentially explosive mixture. During set up check 
all connections and fittings for leaks using soapy water. Never use 
flame. Bubbles indicate a leak. Check that the connection is not 
cross threaded and that it is tight. Perform another leak check. If 
there is still a leak, remove the cylinder and contact Mr. Heater 
direct for service or repair.

Use for water heating only. Never alter in anyway or use with
any device or part not expressly approved by Mr. Heater.

This appliance is designed to be used with a source water
temperature of 60

°

°F or below

The maximum temperature rise from the appliances 

is 

35À F

to

 

the  shower  head  and  42À  F  from  the  source  water

temperature

.

For safety the appliance is designed to shut off the burner
when the water temperature from either of the outlets
reaches 122

°

F/50

°

C

The average run time for the XCW20 from a fully charged
battery is 30 - 40 mins before it will require recharging

During operation ensure that all air inlets and exhaust
(front,sides and back) are kept free from obstructions and
closure.

SAFETY FEATURES

This appliance is equipped with the following safety
features:

Over Temperature Sensor – the appliance will not
allow the burner to remain in operation once the outlet
water temperature reaches 122ÀF/50

°

C.

Water Flow Sensor – water must be flowing through
the system to allow the burner to ignite. In the case
that the water supply is restricted or ceases, the burner
will be extinguished and will not relight.

Tilt Switch – in the event that the appliance is tilted past 30

°

during operation the appliance will shut down until it is
located on a level surface.

CONTROL PANEL 

OPERATING SHOWER INSTRUCTIONS

1.

Attach the Quick Connect Fitting for the pump on the
backside of shower unit  (FIG. 1) and attach the shower

head hose Quick Connect Fitting on the front side of shower
unit (FIG. 2).

2.

Submerge the pump in a suitable reservoir of water. The pump
motor can be damaged if it is not fully submerged in water
while in use.
DO NOT use water from rivers or  lakes

.

 

S

ediment can damage

the pump and the appliance. DO NOT use in ocean

 because

salt water

 

can damage the pump and appliance.

WARNING: This appliance will not heat the water enough to
kill potentially dangerous microbes. DO NOT use this appliance
for potable water.

3.

Screw propane clockwise into shower unit regulator.

4.

Press the Power button, the unit will switch on and the shower
head OUTLET icon will automatically be selected on the control
panel.(FIG. 3) Make sure the shower is fully charged. Ensure
that the Switch on the shower head is in the „Open‰ position
by sliding the switch downwards. (FIG. 4)

AIR INLETS 

AND 

EXHAUST

PUMP INPUT

PUMP 

Quick-Connect

SHOWER HEAD 

Quick-Connect

Switch

ON

FIG. 1

FIG. 2

Battery Level Indicator

Outlet Indicator

System On / Off

Pump On / Off

Switch Between 

Shower head 

and Faucet

Output Temp Control

Water Outlet Temp

Burner “ON” Indicator

Water Inlet 

Temp

Over-
Temp

Indicator

FIG. 3

FIG. 4

Summary of Contents for BOSS XCW20

Page 1: ...open flame Shut off gas to appliance BATTERY OPERATED SHOWER SYSTEM Fully Portable Instant Hot Water Shower 2015 OPERATING INSTRUCTIONS AND OWNER S MANUAL READ INSTRUCTIONS CAREFULLY Read and follow a...

Page 2: ...AFETY PRECAUTIONS ARE ESSENTIAL WHEN ANY MECHANICAL OR PROPANE FUELED EQUIPMENT IS INVOLVED THESE PRECAUTIONS ARE NECESSARY WHEN USING STORING AND SERVICING FOLLOWING THESE SAFETY ALERTS WILL REDUCE T...

Page 3: ...fuel type approved for the appliance Check for gas leaks with soapy water DO NOT USE A FLAME TO CHECK FOR LEAKS CAUTION Certified for use only with LP gas cylinders of the U S Department of Transporta...

Page 4: ...re reaches 122 F 50 C Water Flow Sensor water must be flowing through the system to allow the burner to ignite In the case that the water supply is restricted or ceases the burner will be extinguished...

Page 5: ...e finished with the appliance slide the Switch to the OFF position and depress the Pump button to stop the flow of water to the appliance OPERATING FAUCET INSTRUCTIONS 1 Press the power button and onc...

Page 6: ...rs IMPORTANT If the appliance is not being used or is stored it must be recharged every three months to guarantee the battery life expectancy Failure to do so may result in battery failure STORAGE WAR...

Page 7: ...onnecting when servicing controls Wiring errors can cause improper and dangerous operation The parts lists and wiring diagram show the appliance as it was constructed Do not use a heater which is diff...

Page 8: ...that the water is flowing from shower head Check that water is not over temperature Check that battery does not require re charging Check the Flow Switch on shower head make sure it is fully open Wate...

Page 9: ...Panel 35559 1 17 Board LED 35560 1 18 Tube Gas Inlet 35561 1 19 Valve Water 35562 1 20 Probe Water Temp Outlet 35563 1 21 Tube Gas Outlet 35564 1 22 Tube Water Outlet 35565 1 23 Controller 35566 1 24...

Page 10: ...LACEMENT PARTS USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY ANSI Z21 96 2014 CSA...