PAGE 30 — DCA15SPXU4F • OPERATION MANUAL — REV. #1 (02/10/17)
MAINTENANCE
*
1
During initial operation of a new engine, change oil and filter at 50 hours first time ONLY. Service interval depends on type of oil.
*
2
Add “Supplemental Coolant Additives (SCA’S)” to recharge the engine coolant.
*
3
Replace primary air filter element when restriction indicator shows a vacuum of 625 mm (25 in. H
2
0).
*
4
If blowby hose needs to be replaced, ensure that the slope of the blowby hose is at least a 1/2 inch per foot, with no sags or dips that could
collect moisture and/or oil.
*
5
A
ccumulation of carbon (soot, unburned fuel) in the exhaust pipe line and muffler could cause not only system derates but also could lead to fire
incident. To destroy the soot and unburned fuel, run the unit at rated power for some period of time until the exhaust gas become mostly colorless
every 250 hours operation time. The carbon will be easier to be generated when the unit operates at less then 30% of rated power. In this case,
perform the above procedures at shorter interval time.
*
6
A
pplying a large load at one time to the unit when carbon deposits have accumulated in the exhaust system could produce fire/sparks which
could lead to abnormal combustion. Therefore it is recommended to
appy the load gradually
and observe the exhaust gas color (colorless)
during the process.
*
7
Fire or sparks may emitt from the exhaust gas outlet during the
carbon emission accumulation check
(load). Make sure the area surrounding
the unit is free from any
flammable
material.
Table 10. Inspection/Maintenance
10 Hrs
DAILY
100 Hrs 200 Hrs 250 Hrs 400 Hrs 500 Hrs
1000
Hrs
Engine
Check Engine Fluid Levels
X
Check Fuel Level
X
Check Battery Acid Level
X
Check Fan Belt Condition
X
Check for Leaks
X
Check for Loosening of Parts
X
Change Engine Oil *
1
X
Clean Air Filter
X
Replace Engine Oil and Filter *
1
X
Drain Fuel Tank
X
Clean Unit, Inside and Outside
(Check Emission Carbon)
X
X
Replace Fuel Filter
X
Replace Air Filter Element *
3
X
Clean Radiator and Check
Coolant Protection Level*
2
X
Check all Hoses and Clamps *
4
X
Clean Inside of Fuel Tank
X
Generator
Measure Insulation Resistance
Over 3M ohms
X
Check Rotor Rear Support
Bearing
X
Summary of Contents for WHISPERWATT Series
Page 38: ...PAGE 38 DCA15SPXU4F OPERATION MANUAL REV 1 02 10 17 GENERATOR WIRING DIAGRAM ...
Page 39: ...DCA15SPXU4F OPERATION MANUAL REV 1 02 10 17 PAGE 39 ENGINE WIRING DIAGRAM ...
Page 40: ...PAGE 40 DCA15SPXU4F OPERATION MANUAL REV 1 02 10 17 BATTERY CHARGER WIRING DIAGRAM ...
Page 41: ...DCA15SPXU4F OPERATION MANUAL REV 1 02 10 17 PAGE 41 ENGINE BLOCK HEATER WIRING DIAGRAM ...