![MQ Multiquip WHITEMAN Series Manual Download Page 24](http://html.mh-extra.com/html/mq-multiquip/whiteman-series/whiteman-series_manual_1844254024.webp)
PAGE 24 — STXDF TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #0 (11/05/18)
INSPECTION
FLUID LEVELS
Record the following fluid levels on Machine Information and
Maintenance Log in Inspection section. Refer to Fluid Fill and
Check section for procedure.
Engine Oil
Engine Coolant
Hydraulic Oil
MECHANICAL
1.
Grease Points
— Ensure that the following Grease
Points are greased, wiped down and capped:
• Thrust Collar
• Fingers
2.
Hydraulics
• Spot check paint marks on fittings.
• Ensure that there are no leaks.
3.
Retardant Spray System
• Fill with water and perform operational check.
• Verify no leaks.
4.
Electrical (Cooling Fan)
• Verify fan cycles on when key is turned on
(will remain on for 10s).
• Verify air flow direction is inward.
5.
Lights
• Verify operation of all 6 machine lights.
6.
Switches
• Verify proper operation of all switches.
7.
Diagnotic Display
• Turn the ignition key clockwise to the ON position. All
diagnostic display functions should be available.
8.
Aesthetics
• Paint Quality
- No bare spots
- No scratches
• Decals
- Readable
-Not torn or scratched