background image

 

clean the filter regularly reduces the hood performance, and may cause the fire. 
The filter shall be cleaned at least every 35 hours of hood operation. 
 

Coal filter 

The hood may be equipped with the coal filter. The coal filter is used when the 
hood is not connected to ventilation duct only. The filter shall be installed on 
the fan body, like it is shown in the drawing (Fig.13). The coal filter shall be 
replaced every 6 months. 

NOTE: 

Do not wash or regenerate the coal filter.

 

Mark                filter installation
Mark                filter removal

Fig. 13 Coal filter replacement.

2

2

1

3

1

 

Light replacement 

Before starting any works related to the light replacement, switch off the power.  
If  the  hood  was  previously  turned  on,  wait  previously  until  the lams  become 
cold,  and  then  start  their  replacement.  The  lamp  replacement  is  illustrated  in 
Figure 14. 

Summary of Contents for MPM-50-PX-51

Page 1: ...MPM agd S A ul Brzozowa 3 05 822 Milan wek Tel 48 22 380 52 00 Fax 48 22 724 70 00 E mail mpm mpm pl www mpm pl MPM 50 PX 51 52 MPM 60 PX 61 62 Under Cabinet Range Hood Operation Manual...

Page 2: ...ood assembly please read attentively this Operation Manual It will allow you to avoid any mistakes in course of installation and problems in course of range hood operation The cooking range hood is de...

Page 3: ...ing the assembly Any assembly or maintenance operations shall be performed in the protective gloves Do not use the hood without the correctly installed filter The assembly non complying with this Oper...

Page 4: ...by the persons with limited physical mental abilities or by persons with a lack of experience in device operation provided that the due supervision or training in terms of the safe device operation wa...

Page 5: ...ctronic equipment collection points The operators of the collection points including the local collection points retailers and municipal entities provide the creation of network for such devices and b...

Page 6: ...anual and in the labels attached to the hood have been obtained by measurements and calculations made according to the EU resolution No 65 2014 and 66 2014 Fig 1 General view of the range hood Control...

Page 7: ...o type pipes is not recommended Use the flue channel with as low number of bends as possible the bending angles shall not exceed 90 The changes in flue channel sections are not advised from higher sec...

Page 8: ...Fig 3 Change of the hood function a b c Plug part under the plug 2 1 Fig 4 Chimney instalation Symbol chimney instalation Symbol chimney disassembly 1 2...

Page 9: ...stance of hood hanging between the surface of kitchenware placement over the cooking range gas electric range and lowest part of the hood Fig 6 shall amount at least 45 cm for electric cooking ranges...

Page 10: ...e mounted If it is not possible protect the furniture elements remaining in the adjacent area Check if there is a socket near the mounting area and control if the hood may be connected to the ventilat...

Page 11: ...en screw in the screws on their places 5 Mount the filter as shown at the Fig 8 in the reverse order Hood assembly to the wall 1 Define the axis of cooking range and project it onto the wall where the...

Page 12: ...Fig 7 Hood to the cabinet assembly Fig 8 Aluminium fat filter removing 2 2 1...

Page 13: ...O4x16 340 225 LO 50 LO 496mm 60 LO 596mm Fig 9 Hood assembly to the wall Fig 10 Assembly dimensions 320mm 4xO8 320mm L 17mm 62mm...

Page 14: ...Fig 11 Screw plugs assembly 2 x O5 x 45mm 4 x O8 x 40mm 7mm A Fig 12 Hood hanging...

Page 15: ...OT EVER USE ANY ALCOHOL BASED DETERGENTS FOR HOOD CLEANING The satin inox elements shall be cleaned with special liquids NOTE The failure to comply with the instructions concerning the device cleaning...

Page 16: ...installed on the fan body like it is shown in the drawing Fig 13 The coal filter shall be replaced every 6 months NOTE Do not wash or regenerate the coal filter Mark filter installation Mark filter re...

Page 17: ...allation Mark lamp removal Hood operation control The hood is equipped with the mechanical control system button 0 hood fan switched off button 1 hood fan switched on with minimum speed button 2 hood...

Page 18: ...d aluminium filters shall be kept clean the recommended time of work of aluminium filter between its cleaning max 35h of hood operation The ventilation ducts shall not be blocked The fan operation spe...

Page 19: ...Product characteristics Product characteristics are placed inside the hood...

Page 20: ...h the hood off 6 At the forth speed 4 is pulsing after 5 minutes the speed is decreased to a third speed The hood is equipped with the turbo mode which decreases the speed automatically for energy sav...

Reviews: