6.4 Plumbing Installation
Overview: There are three dip tubes and hoses that will need to be installed.
6.4.1 Dip Tubes Installation
Some pipe fittings are sent loose, and extra fittings are included to allow for optimal
configurations.
Use quality pipe sealant/tape when installing. Tighten fittings securely.
Install Inlet, Return, and Overflow fittings and dip tubes.
•
Suction Inlet(s)
– Dual 1 ¼” vs Single 2” explanation
o
The standard installation kit will come with two -
1 1/4” suction inlets to
accommodate lower coolant levels while running and help prevent air from
being pulled into the pump.
o
For dual inlets, a minimum coolant depth of 4” while running coolant is
required.
o
A single 2” inlet can be used for deep tanks (14” +), with single conveyor
outflow.
▪
Only certain models of machines will get this type of install kit.
o
For a single inlet, a minimum coolant depth of 6” must be maintained when
running.
•
Install Pump Inlet Fitting(s)
1 ½” Return
Dual 1 ¼” Inlets
-or-
2” Single Inlet
1 ¼” Overflow