ATTENTION

 

In order to ensure reliable operations, please make sure the 
operating temp. of the environment does not exceed the spec. 
When mounting a SDS-3016 with other operating units in a 
cabinet without forced ventilation, minimum spacing of 3cm on 
both sides and above/below the switch is recommended. 

 

Wiring Requirements 

 

ATTENTION 

Safety First! 

Be sure to disconnect the power cord before installing and/or 
wiring your Moxa Industrial Smart Ethernet Switch. Calculate the 
maximum possible current in each power wire and common wire. 
Observe all electrical codes dictating the maximum current 
allowable for each wire size. If the current goes above the 
maximum ratings, the wiring could overheat, causing serious 
damage to your equipment. 

 

Be sure to read and follow these important guidelines: 

 

Use separate paths to route wiring for power and devices. If power 
wiring and device wiring paths must cross, make sure the wires are 
perpendicular at the intersection point. 

NOTE 

Do not run signal or communications wiring and power wiring 
through the same wire conduit. To avoid interference, wires with 
different signal characteristics should be routed separately. 

 

 

You can use the type of signal transmitted through a wire to 
determine which wires should be kept separate. The rule of thumb is 
that wiring that shares similar electrical characteristics can be 
bundled together. 

 

You should separate input wiring from output wiring. 

 

We advise that you label the wiring to all devices in the system. 

Grounding the Industrial Smart Ethernet Switch 

Grounding and wire routing help limit the effects of noise due to 
electromagnetic interference (EMI). Run the ground connection from the 
ground screw (chassis ground) to the grounding surface prior to 
connecting devices. 

 

ATTENTION 

This product is intended to be mounted onto a well-grounded 
mounting surface, such as a metal panel. 

 

 

Summary of Contents for SDS-3016 Series

Page 1: ...1 1802030160011 SDS 3016 Series Quick Installation Guide Moxa s Industrial Smart Ethernet Switch Version 1 1 February 2021 Technical Support Contact Information www moxa com support 2021 Moxa Inc All...

Page 2: ...d Warranty card Features 14 10 100BaseT X and 2 10 100 1000BaseT X or 100 1000BaseSFP Web based graphical user interface for quick configuration and management Web based graphical user interface for p...

Page 3: ...status LEDs top to bottom STATE LED indicator Green FAULT LED indicator Red PWR1 LED indicator Amber PWR2 LED indicator Amber 3 G1 G2 port status LEDs LED lights in Green 1000 Mbps LED lights in Amber...

Page 4: ...output R and digital input DI 9 Reset button 10 USB storage port type A connector 11 DIN rail mounting kit 12 Screw hole reserved for other DIN rail mounting methods for more information please see th...

Page 5: ...1 Insert the upper lip of the DIN rail kit into the mounting rail STEP 2 Press the SDS 3016 towards the mounting rail until it snaps into place Suggested Removal Method STEP 1 Pull down the latch on...

Page 6: ...STEP 3 Press the SDS 3016 towards the mounting rail until it snaps into place Suggested Removal Method STEP 1 Pull down the latch on the DIN rail kit with a screwdriver STEPS 2 3 Slightly pull the SDS...

Page 7: ...or power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring...

Page 8: ...e supply voltage connections and to the signal contact with the Safety Extra Low Voltages SELV NOTE We suggest the length of the pin type cable terminal is 8 mm In order to tighten the wire properly u...

Page 9: ...the relay contacts will form an open circuit when a user configured event is triggered If a user configured event does not occur the circuit remains closed as the relay itself is closed Examples of us...

Page 10: ...he terminal block receptor which is located on the top panel of the SDS 3016 Wiring the Redundant Power Inputs 12 24 48 VDC The SDS 3016 has two sets of power inputs power input 1 PWR 1 P1 and power i...

Page 11: ...tem log file backup USB Storage Port Type A Connector Pinouts Pin Description 1 VCC 5V 2 D Data 3 D Data 4 GND Ground NOTE ABC 02 USB Installation Plug the ABC 02 USB into the USB storage port of the...

Page 12: ...he type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port In the following section we give pinout information for both MDI...

Page 13: ...cal signals optical signals do not require a circuit in order to transmit data Consequently one of the optical lines is used to transmit data from device I to device II and the other optical line is u...

Page 14: ...otate the DIP switch Rotary DIP Switch Settings for IA Profile Indicator Mode 0 Modbus TCP profile Default 1 PROFINET profile enabled 2 PROFINET profile and DHCP client enabled 3 Ethernet IP profile e...

Page 15: ...t Power is being supplied to the main system s power input PWR2 Light off Power is not being supplied to the main system s power input PWR2 STATE Green Solid light System has passed self diagnosis tes...

Page 16: ...r 10 100 Mbps SFP Port LED 1000M Green Solid Light When the port is active and links at 1 000 Mbps Blinking When the port s data is being transmitted at 1 000 Mbps Light off When the port is inactive...

Page 17: ...IB IF MIB LLDP MIB BRIDGE MIB Q BRIDGE MIB Switch Properties Max Number of VLANs 8 VLAN ID Range VID 1 to 4094 MAC Table Size 8 K Packet Buffer Size 3 Mbit Interface RJ45 Ports 10 100BaseT X auto nego...

Page 18: ...15B Class A EMS IEC 61000 4 2 ESD Contact 4 kV Air 8 kV IEC 61000 4 3 RS 80 MHz to 1 GHz 10 V m IEC 61000 4 4 EFT Power 1 kV Signal 1 kV IEC 61000 4 5 Surge Power 2 kV Signal 1 kV IEC 61000 4 6 CS Sig...

Page 19: ...equirements If the device needs to be cleaned it should be wiped with a dry cloth The device must be installed within a suitable secure final enclosure If the equipment is used in a manner not specifi...

Reviews: