Specifications
Technology
Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
Software Features
Management
IPv4/IPv6, SNMP v1/v2c/v3, LLDP, Port Mirror,
DHCP Client, Syslog, SNMP Inform, Flow
Control, Back Pressure Flow Control
Filter
IEEE 802.1Q VLAN
Redundancy Protocols
STP, RSTP, MRP (Client)
Security
Broadcast Storm Protection, Port Lock,
SNMPv3, HTTPS
Time Management
SNTP/NTP Server/Client
Industrial Protocols
EtherNet/IP, PROFINET IO, and Modbus/TCP
MIB
RFC1213 MIB, Ether-Like MIB, IF MIB,
LLDP-MIB, BRIDGE MIB, Q-BRIDGE MIB
Switch Properties
Max. Number of VLANs 8
VLAN ID Range
VID 1 to 4094
MAC Table Size
8 K
Packet Buffer Size
3 Mbit
Interface
RJ45 Ports
10/100BaseT(X) auto negotiation speed
10/100/1000BaseT(X) auto negotiation speed
Fiber Ports
100/1000BaseSFP
Storage Port
USB storage (Type A connector for
ABC-02-USB)
Alarm Contact (Relay
Output)
1 normally open solid-state relay output with
current carrying capacity of 1 A @ 24 VDC
Digital Input
1 input with the same ground, but electrically
isolated from the electronics.
• +13 to +30 V for state “1”
• -30 to +3 V for state “0”
• Max. input current: 8 mA
Button
Reset button
Power Requirements
Input Voltage
12/24/48/-48 VDC, redundant dual inputs
Input Current
SDS-3016-2GTX: 12-48 VDC, 0.858 A (max.)
SDS-3016-2GSFP: 12-48 VDC, 0.99 A (max.)
Overload Current
Protection
Supported
Connection
2 removable 4-contact terminal blocks
Reverse Polarity
Protection
Supported