ATTENTION
This is a Class 1 Laser/LED product. To avoid causing serious
damage to your eyes, do not stare directly into the Laser Beam.
Rotary DIP Switch
The SDS-3016 switches are classified as smart Ethernet switches. The
rotary DIP switches located on the bottom panel of SDS-3016 facilitate
one-step configuration to enable Industrial Protocol and DHCP client in
only a few seconds without having to use a web browser.
The Rotary DIP switch has ten options that can be selected by pointing the
arrow in that direction. The default setting 0 is reserved for the Modbus
TCP profile. The options 1 to 4 can be used for PROFINET, Ethernet/IP
Profile, and DHCP clients. The options 5 to 9 are reserved for future use.
Please reboot the device after changing the rotary DIP switch settings to
enable the function.
NOTE
We strongly recommend to use a 2.0 mm flathead screwdriver to
rotate the DIP switch.
Rotary DIP Switch Settings for IA Profile:
Indicator Mode
0
Modbus TCP profile (Default)
1
PROFINET profile enabled
2
PROFINET profile and DHCP client enabled
3
Ethernet/IP profile enabled
4
Ethernet/IP profile and DHCP client enabled
Others
Reserved (perform the same behavior as Indicator 0.)
Reset Button
The reset button can perform two functions. One is to reset the industrial
smart Ethernet switch back to factory default settings and the other is to
perform a quick back up of configuration and log files to the ABC-02-USB
automatic backup configurator.
Reset to Factory Default Settings
Use a pointed object, such as a straightened paper clip, to depress and
hold the reset button for 5 seconds. This will cause the state LED to blink
once a second. After depressing the button for 5 seconds, the state LED
will start to blink rapidly. This indicates that factory default settings have
been loaded and executed, and that you can release the reset button.
NOTE
Do NOT power off your Moxa industrial smart Ethernet switch
when the default settings are loading.