Summary of Contents for ioLogik R2110 Series

Page 1: ...s Manual RS 485 Remote I O Server with 12 DI 8 DO First Edition July 2006 www moxa com product MOXA Technologies Co Ltd Tel 886 2 8919 1230 Fax 886 2 8919 1231 Web www moxa com MOXA Technical Support...

Page 2: ...ommitment on the part of MOXA MOXA provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose MOXA reserves the right to...

Page 3: ...ew 3 2 Installing ioAdmin 3 2 Searching for the ioLogik R2110 3 3 Monitoring I O Status 3 5 On line Wiring Guide 3 6 Modbus RTU 3 7 Server Information 3 8 Logging In 3 8 Configuring Digital Input Outp...

Page 4: ...Appendix B Factory Default Settings B 1 Appendix C Port Pinout Diagrams C 1 Serial Port Pinouts C 1 Appendix D Service Information D 1 MOXA Internet Services D 2 Problem Report Form D 3 Product Return...

Page 5: ...er an RS 485 connection for use in automation applications The following topics are covered in this chapter Overview Features of the ioLogik R2110 RS 485 Remote I O Server Package Checklist Product Sp...

Page 6: ...Remote I O Server y 12 DI digital input channels 8 DO digital output channels y Multi functional I O that supports DI Event Counter and DO Pulse Output y Connects to RS 485 network using Modbus proto...

Page 7: ...e R2000 series of ioLogik Remote I O servers Serial 2 wire RS 485 for module cascading terminal block 3 81 mm supports data data Baudrate up to 115 2 kbps Built in ADDC 15 KV ESD for all serial signal...

Page 8: ...Input Dry contact Logic 0 close to GND Logic 1 open Wet contact Logic 0 0 to 3 VDC Logic 1 10 to 30 VDC Low speed counter for limit switch with filtering in 10 ms intervals Excess voltage protection...

Page 9: ...DO 1 DO 2 DO 3 DO 4 DO 5 DO 6 DO 7 DO GND Setting the RS 485 Communication Speed The RS 485 port on the ioLogik R2110 is used to communicate with other RS 485 devices or to link to another RS 485 I O...

Page 10: ...allation procedure for the ioLogik R2110 remote I O server The following topics are covered in this chapter Connecting the Hardware Connecting the Power Grounding the ioLogik R2110 Connecting to I O D...

Page 11: ...terminal block If the power is properly supplied the power LED will glow a solid red color until the system is ready Grounding the ioLogik R2110 The ioLogik R2110 is equipped with two protection grou...

Page 12: ...eady Flashing Red Green The ioLogik is in safe status Serial Blinking The serial port is receiving and transmitting data DI O LEDs DI 12 pins DO 8 pins Field PWR In 0 1 2 3 4 5 6 7 8 9 10 11 Out 0 1 2...

Page 13: ...ps 115200 This is the default home page showing the unit ID and baudrate Press the down button to begin navigating the setting options ioLogik R2110 server Enter this submenu to access the following i...

Page 14: ...ring I O Status On line Wiring Guide Modbus RTU Server Information Logging In Configuring Digital Input Output Channels Testing DI O Channels Configuring Digital Input Channels Configuring Digital Out...

Page 15: ...re y ioAdmin y ioLogik R2110 Wiring Guide y MXIO DLL library coming soon Installing ioAdmin Insert the CD ROM from the network adaptor package into the host computer Run SETUP EXE which is located in...

Page 16: ...Searching for the ioLogik R2110 From the pull down menu choose System Auto Scan Remote I O Server A system dialog window will pop up Make sure that RS 232 485 I O server is selected and click on Port...

Page 17: ...Start Search ioAdmin will begin searching up to 99 ports for your ioLogik R2110 The timeout interval is for RS 485 communication and defaults to 2000 ms As soon as your ioLogik R2110 appears as shown...

Page 18: ...min is unable to find your ioLogik R2110 you may still access the On line Wiring Guide Please refer to the On line Wiring Guide section for details Monitoring I O Status Once the ioLogik R2110 is foun...

Page 19: ...ioAdmin 3 6 On line Wiring Guide To access the On line Wiring Guide right click on the ioLogik R2110 graphic then left click on Wiring Guide This displays a help file showing the wiring information a...

Page 20: ...Guide through the Help menu on the menu bar Modbus RTU The RS 485 port runs Modbus RTU that can connect to any Modbus devices You may use different methods to connect different combinations of ioLogi...

Page 21: ...e ioLogik R2110 In order to obtain full access to configuration settings and other functions you will need to first log in under the Management tab regardless of whether or not you have set up passwor...

Page 22: ...in 3 9 Testing DI O Channels You may test each DI O channel with ioAdmin The settings are as follows DI DI depends on the device DI Counter activate or stop event counting DO DO change status of the D...

Page 23: ...gital Input Channels The ioLogik R2110 is equipped with 12 digital inputs that can be set individually to DI or Event Counter mode In DI mode the specification is as follows Dry contact Logic 0 OFF sh...

Page 24: ...iltering It is configurable in multiples of 10 ms For example a setting of 2 would mean a 20 ms filter 2 x 10 ms The maximum value allowed by the software filter is 65535 Setting the filter to 0 cause...

Page 25: ...ith 8 digital output sink channels that can be set individually to DO or Pulse Output mode In DO mode the specification is Logic 0 OFF open Logic 1 ON short You may also configure whether the DO statu...

Page 26: ...is 232 You may also configure how the output pulse is handled when the ioLogik R2110 is powered on or in safe status If Start is checked off in the Power On Settings the output pulse will commence as...

Page 27: ...Counter mode you can configure whether or not counting starts or continues when Safe Status has been activated For DO channels in DO mode you can configure whether or not the DO is set to OFF or ON a...

Page 28: ...nual Configuring with ioAdmin 3 15 Restarting the System You may use the Restart System command to restart the ioLogik R2110 from a remote site Restoring Default Settings You may use ioAdmin to reset...

Page 29: ...O Server 12DI 8DO 2 System and I O Configurations DI00 DI n a DI01 DI n a DI02 DI n a DI03 DI n a DI04 DI n a DI05 DI n a DI06 DI n a DI07 DI n a DI08 DI n a DI09 DI n a DI10 DI n a DI11 DI n a DO00...

Page 30: ...0004 DO05 Output 00006 0005 0x0005 DO06 Output 00007 0006 0x0006 DO07 Output 00008 0007 0x0007 END Password Protection The ioLogik R2110 can be protected by password under the Management tab The login...

Page 31: ...ioLogik R2110 Series User s Manual Configuring with ioAdmin 3 18 Firmware Upgrade Screens...

Page 32: ...Value 0 Off 1 On 00016 0x000F 1 bit CH7 DO Power On Value 0 Off 1 On 00017 0x0010 1 bit CH0 DO Safe Value 0 Off 1 On 00018 0x0011 1 bit CH1 DO Safe Value 0 Off 1 On 00019 0x0012 1 bit CH2 DO Safe Valu...

Page 33: ...bit CH3 DI Counter Status 0 Off 1 On 00043 0x0034 1 bit CH4 DI Counter Status 0 Off 1 On 00044 0x0035 1 bit CH5 DI Counter Status 0 Off 1 On 00045 0x0036 1 bit CH6 DI Counter Status 0 Off 1 On 00056...

Page 34: ...1 bit CH1 DI Counter Overflow Status Read 0 Normal 1 Overflow Write 0 clear overflow status 1 return Illegal Data Value 00075 0x004A 1 bit CH2 DI Counter Overflow Status Read 0 Normal 1 Overflow Writ...

Page 35: ...x005C 1 bit CH8 DI Counter Trigger 0 Low to High 1 High to Low 00094 0x005D 1 bit CH9 DI Counter Trigger 0 Low to High 1 High to Low 00095 0x005E 1 bit CH10 DI Counter Trigger 0 Low to High 1 High to...

Page 36: ...iption 30001 0x0000 word CH0 DI Counter Value Hi Byte 30002 0x0001 word CH0 DI Counter Value Lo Byte 30003 0x0002 word CH1 DI Counter Value Hi Byte 30004 0x0003 word CH1 DI Counter Value Lo Byte 30005...

Page 37: ...utput Count Value Hi Word 40016 0x000F word CH7 DO Pulse Output Count Value Lo Word 40017 0x0010 word CH0 DO Pulse Low Signal Width 40018 0x0011 word CH1 DO Pulse Low Signal Width 40019 0x0012 word CH...

Page 38: ...lue 40054 0x0035 word CH1 DI Mode 0 DI 1 Counter Others return Illegal Data Value 40055 0x0036 word CH2 DI Mode 0 DI 1 Counter Others return Illegal Data Value 40056 0x0037 word CH3 DI Mode 0 DI 1 Cou...

Page 39: ...s User s Manual Modbus RTU Address Mappings A 8 Function 8 Sub function Data Field Request Data Field Response Description 0x0001 0x0000 Echo Request Data Reboot 0x0001 0xFF00 Echo Request Data Reset...

Page 40: ...Default baudrate 115200 Kbps Communication watchdog Disable DI Mode DI Filter time 1 10 ms Trigger for counter Lo to Hi Counter status Stop DO Mode DO DO Safe Status Off Power on status Off Low width...

Page 41: ...C C Appendix C Port Pinout Diagrams Serial Port Pinouts ioLogik R2110 RS 485 Network Adapter Pin Assignment...

Page 42: ...ains information on how to contact MOXA for information about this and other MOXA products as well as the procedure for reporting problems In this appendix we cover the following topics MOXA Internet...

Page 43: ...customers receive the full benefit of our products MOXA Internet Services has been set up to provide technical support driver updates product information and user s manual updates The following servi...

Page 44: ...Fax Email Date Product Model ioLogik R2110 RS 485 Remote I O Server Serial Number _________________ Problem Description Please describe the symptoms of the problem as clearly as possible including any...

Page 45: ...turn Agreement PRA from the sales representative or dealer Fill out the Problem Report Form PRF Include as much detail as possible to expedite diagnosis of your product Carefully pack the product in a...