Grounding the Moxa Industrial Rackmount Switch   

Grounding and wire routing help limit the effects of noise due to 
electromagnetic interference (EMI). Run the ground connection from the 
ground screw to the grounding surface prior to connecting devices. 

NOTE 

Using a shielded cable achieves better electromagnetic 
compatibility. 

 

Connecting the Power Inputs 

The IKS-6728A-8PoE switches support 4 types of power supply. 

 

IKS-6728A-8PoE-4GTXSFP-HV-HV-T: Two isolated 110/220 VAC (85 
to 264 VAC) power supplies for switch and two isolated 48 VDC power 
inputs for PoE+ ports 

 

IKS-6728A-8PoE-4GTXSFP-HV-T: One isolated 110/220 VAC (85 to 
264 VAC) power supply for the switch and one isolated 48 VDC power 
input for the PoE+ ports 

 

IKS-6728A-8PoE-4GTXSFP-48-48-T: Two isolated 48 VDC power 
supplies for switch and PoE+ ports 

 

IKS-6728A-8PoE-4GTXSFP-48-T: One isolated 48 VDC power supply 
for switch and PoE+ ports 

For the HV models, the 110/220 VAC power supplies provide power for 
switch operation. Separate 48 VDC power supplies are required to provide 
power to all PoE+ ports (50 to 57 VDC is recommended for IEEE 802.3at 
devices). 
For the 48 VDC models, the 48 VDC power supplies provide power for 
switch operation and to all PoE+ ports (50 to 57 VDC is recommended for 
IEEE 802.3at devices). 
The IKS-6700A switches support 3 types of power supply: 

 

IKS-6726A/6728A HV series: Two isolated 110/220VAC (85 to 264 
VAC) power supplies for switch 

 

IKS-6726A/6728A 24/48VDC series: Two isolated 24 or 48VDC power 
supplies for switch 
 

Wiring Requirements 

 

WARNING 

Do not disconnect modules or wires unless power has been 
switched off or the area is known to be non-hazardous. The 
device may only be connected to the supply voltage shown on the 
type plate. The device is designed for operation with a Safety 
Extra-Low Voltage (SELV) or an isolated power supply, which 
means that they may only be connected to the supply voltage 
connections and to the signal contact with a SELV or an isolated 
power supply in compliance with IEC 60950-1/EN 60950-1 or UL 
508. 

 

AC Power Inlets 

The connection for PWR1 (power supply 1) and PWR2 (power supply 2) 
are located on the rear panel (shown below). Be sure to use a standard 

Summary of Contents for IKS-6728A-8PoE series

Page 1: ...2014 Moxa Inc All rights reserved P N 1802067000010 IKS 6700A and IKS 6728A 8PoE Series Hardware Installation Guide First Edition September 2014...

Page 2: ...and software CD Hardware installation guide CD ROM with user s manual and SNMP MIB file Moxa product warranty statement Panel Layouts 1 System status LEDs 2 Model name 3 Reset button 4 Terminal block...

Page 3: ...3 14 Grounding screw 15 Power sockets for AC power inputs or terminal blocks for DC power inputs Dimensions Unit mm inch Fast Ethernet Interface Modules IM 6700A Series...

Page 4: ...ate 48 VDC power supplies are required to provide power to all PoE ports 50 to 57 VDC is recommended for IEEE 802 3at devices For the 48 VDC models the 48 VDC power supplies provide power for switch o...

Page 5: ...elay contact of the 2 pin terminal block connector is used to detect user configured events The two wires attached to the fault contacts form an open circuit when a user configured event is triggered...

Page 6: ...described in the table below LED Color State Description System LEDs PWR1 AMBER On Power is being supplied to the main module s power input PWR1 Off Power is not being supplied to the main module s po...

Page 7: ...n When the system is importing exporting data from or to an ABC 02 USB automatic backup device the FAULT MSTR HEAD and CPLR TAIL LEDs will blink in sequence Port Status LEDs G1 to G4 1000M TP ports le...

Page 8: ...nology Standards IEEE 802 3af at for Power over Ethernet IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X and 100BaseFX IEEE 802 3ab for 1000BaseT X IEEE 802 3z for 1000BaseX IEEE 802 3x for Flow Con...

Page 9: ...24 T 24 VDC 0 40A IKS 6726A 2GTXSFP 48 48 T 48 VDC 0 21A IKS 6726A 2GTXSFP HV HV T 110 VAC 0 33A 230VAC 0 24A IKS 6728A 4GTXSFP 24 24 T 24VDC 0 44A IKS 6728A 4GTXSFP 48 48 T 48VDC 0 23A IKS 6728A 4GT...

Page 10: ...he manufacturer 2 Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised 3 Mechanical Loadi...

Page 11: ...are extremely hot Before touching the equipment you must take special precautions to protect your hands and body from serious injury Technical Support Contact Information www moxa com support Moxa Ame...

Reviews: