Moxa Technologies IKS-6728A-8PoE series Hardware Installation Manual Download Page 11

 

- 11 - 

who have been instructed on how to handle the metal chassis of 
equipment that is so hot that special protection may be needed before 
touching it. The location should only be accessible with a key or 
through a security identity system. 

 

External metal parts of this equipment are extremely hot!! Before 
touching the equipment, you must take special precautions to protect 
your hands and body from serious injury. 

 
 
 
 
 
 
 
 
 

Technical Support Contact Information 

www.moxa.com/support 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Summary of Contents for IKS-6728A-8PoE series

Page 1: ...2014 Moxa Inc All rights reserved P N 1802067000010 IKS 6700A and IKS 6728A 8PoE Series Hardware Installation Guide First Edition September 2014...

Page 2: ...and software CD Hardware installation guide CD ROM with user s manual and SNMP MIB file Moxa product warranty statement Panel Layouts 1 System status LEDs 2 Model name 3 Reset button 4 Terminal block...

Page 3: ...3 14 Grounding screw 15 Power sockets for AC power inputs or terminal blocks for DC power inputs Dimensions Unit mm inch Fast Ethernet Interface Modules IM 6700A Series...

Page 4: ...ate 48 VDC power supplies are required to provide power to all PoE ports 50 to 57 VDC is recommended for IEEE 802 3at devices For the 48 VDC models the 48 VDC power supplies provide power for switch o...

Page 5: ...elay contact of the 2 pin terminal block connector is used to detect user configured events The two wires attached to the fault contacts form an open circuit when a user configured event is triggered...

Page 6: ...described in the table below LED Color State Description System LEDs PWR1 AMBER On Power is being supplied to the main module s power input PWR1 Off Power is not being supplied to the main module s po...

Page 7: ...n When the system is importing exporting data from or to an ABC 02 USB automatic backup device the FAULT MSTR HEAD and CPLR TAIL LEDs will blink in sequence Port Status LEDs G1 to G4 1000M TP ports le...

Page 8: ...nology Standards IEEE 802 3af at for Power over Ethernet IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X and 100BaseFX IEEE 802 3ab for 1000BaseT X IEEE 802 3z for 1000BaseX IEEE 802 3x for Flow Con...

Page 9: ...24 T 24 VDC 0 40A IKS 6726A 2GTXSFP 48 48 T 48 VDC 0 21A IKS 6726A 2GTXSFP HV HV T 110 VAC 0 33A 230VAC 0 24A IKS 6728A 4GTXSFP 24 24 T 24VDC 0 44A IKS 6728A 4GTXSFP 48 48 T 48VDC 0 23A IKS 6728A 4GT...

Page 10: ...he manufacturer 2 Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised 3 Mechanical Loadi...

Page 11: ...are extremely hot Before touching the equipment you must take special precautions to protect your hands and body from serious injury Technical Support Contact Information www moxa com support Moxa Ame...