2.3 General warnings &  

information

The product must not be modified.
The product must not be operated without 
safety devices.
Power to the machine must be switched off 
prior to maintenance, repair, or adjustment.
The machine may only be used in perfect 
technical condition and according to its inten-
ded use as described in Section 

3.3 Areas of 

use

. Faults that may jeopardise safety must 

be rectified immediately.
Work on the machine’s electrical equipme-
nt may only be carried out by a licenced 
electrician in accordance with applicable local 
electrical safety regulations.
The machine’s moving parts always consti-
tute a risk (e.g. cutting, clamping or gripping 
points).
Under no circumstances should water be used 
to extinguish/cool in the event of a fire or heat 
generation. A powder extinguisher or other 
suitable extinguisher must be used instead.
Explosive gases must not be transported in 
the hose!
The machine must not be used in a potenti-
ally explosive environment or to extract dust 
and gases in explosive concentrations.
All work on the machine must be carried out 
by certified and authorised personnel.
For maintenance work where contact with 
dust occurs, personal protective equipment 
such as safety glasses, respiratory protection 
and safety gloves must be worn.

The surface on which the machine is instal-
led must be appropriate for the mass of the 
machine.
Regardless of the manual, the machine is 
subject to national and local safety and acci-
dent prevention regulations.
Waste disposal must be carried out in 
accordance with applicable national legisla-
tion.

2 Safety

2.1 General

The product is safe to use. It is designed in such a way 
that hazardous parts are only located in inaccessible 
areas. Even so, if the product is not used correctly or 
as intended, it may be hazardous to the user or cause 
damage to the product. The user should therefore be 
informed and trained to handle the product’s safety 
features.

2.2 Protective equipment

No special protective equipment is required to use the 
product. However, personal protective equipment such 
as safety glasses, respiratory protection, and safety 
gloves must be worn when cleaning the product.

Summary of Contents for ASEM 125

Page 1: ...ASEM 65 85 125 Manual...

Page 2: ...11 Accessories 14 12 Notes 16 TABEL OF CONTENTS 1 Introduction 3 1 1 The manual 3 1 2 Declaration 3 1 3 Warranty 3 1 4 Manufacturer 3 2 Safety 4 2 1 General 4 2 2 Protective equipment 4 2 3 General wa...

Page 3: ...CE certification being voided The warranty period is one year from the date of pur chase and covers the product and its constituent parts All manufacturing defects are covered by the warranty MOVEX r...

Page 4: ...explosive environment or to extract dust and gases in explosive concentrations All work on the machine must be carried out by certified and authorised personnel For maintenance work where contact with...

Page 5: ...85 125 is a motorised hose reel intended for the evacuation of exhaust gases 3 4 Design See Fig 2 1 Bracket 2 Beam 3 Duct connection 4 Drum 5 Hose 6 Motor 7 Declutching system 8 Contact safety device...

Page 6: ...installa tions For electrical installation see Section 10 2 Circuit diagram electronics 4 3 Assembly installation National rules and regulations must always be adhered to during assembly work 4 3 1 Un...

Page 7: ...tment of end position for roll out Rotate the drum counterclockwise as viewed from the motor side until the roll out wheel 3 Fig 7 is obstructed by the stop clip 1 This is indicated by a rattling soun...

Page 8: ...Release motor disconnect switch and refit the cover 11 The hose reel is now ready for mounting and installation 4 3 6 Mounting the hose reel Fasteners used to mount the hose reel on the ceiling or wa...

Page 9: ...crews and open the cover see Fig 12 Fig 12 5 Commissioning 5 1 Start up Any faults must be rectified before turning on the power 1 Switch on the power supply 2 Check the operation of the machine White...

Page 10: ...enance schedule TROUBLESHOOTING GUIDE Symptom Possible cause Recommended action 1 The hose does not stop in the correct position Incorrect end positions have been set Adjust the end positions see sect...

Page 11: ...ical information 10 1 Technical data Dimensions inch See Fig 13 Voltage 115 V 1N Frequency 60 Hz Current 3 3 A Enclosure class IPX4 Speed 12 rpm Torque 855 IN LBS Temperature limits Operating temperat...

Page 12: ...N PE MA1 M Brown Black Blue ASEM RADIO G Y L N L N N Manual MOVEX ASEM 65 85 125 10 2 Circuit diagram electronics 10 2 1 ASEM 1 ASEM 2 10 2 2 ASEM Radio 1 3 2 4 SSB 750 120 V 1N L1 N PE MA1 M Red Blac...

Page 13: ...13 Manual FUMEX ASEM 65 85 125 1 2 3 4 5 6 7 8 9 10 11 12 17 16 15 14 13 21 20 19 18 Manual MOVEX ASEM 65 85 125 10 3 Exploded view drawing...

Page 14: ...ndicator that shows whether the damper is open or closed ASES is an energy sa ving accessory Combine with fan pressure control to further optimise the system AESM 100 125 150 Hose installation kit wit...

Page 15: ...injuries ASB Swing arm for hose reel Includes installation kit hose and pipe parts ASB 1960 ASB 4300 ASB 6300 Length 6 ft Length 14 ft Length 21 ft Weight 97 lb Weight 154 lb Weight 198 lb ASEM RADIO...

Page 16: ...XTRACTION ARMS VEHICLE EXHAUST EXTRACTION FANS FILTERS CURTAINS CONTROLS 12 Notes 104 Commerce Drive Northampton PA 18067 USA Tel 610 440 0478 Fax 610 440 0480 Email info movexinc com www movexinc com...

Reviews: