7 Troubleshooting

Troubleshooting with the power switched 
on may only be carried out by a licenced 
electrician.

7.1 Troubleshooting guide

The troubleshooting guide contains information for 
identifying faults which are simple to rectify. Always 
perform the troubleshooting procedures before  
contacting MOVEX.

8 Maintenance

Please remember that only original spare 
parts may be used.

Make sure that all moving parts are secured to prevent 
unintentional movement.

8.1 Cleaning

The product should be cleaned with clean cloths and 
neutral detergents to avoid damage.

8.2 Maintenance schedule

Depending on the changing operating con-
ditions between the different systems, the 
intervals for recommended maintenance 
may differ. Users should therefore determine 
their own maintenance intervals.

The checklist for maintenance is designed for normal 
use of the machine. The recommended intervals are 
approximate and refer to the time after the first start-up.
MOVEX recommends the following maintenance  
schedule:

TROUBLESHOOTING GUIDE

Symptom

Possible cause

Recommended action

1. The hose does not stop 

in the correct position.

Incorrect end positions have 

been set.

Adjust the end positions; see section  

4.3.8 Adjusting the end positions

.

2. The motor cannot 

retract the hose.

Hose is too heavy.

Use shorter or lighter hose; see torque under  

section 

10.1 Technical data

.

Nozzle is too heavy.

Use lighter nozzle; see torque under sectio

10.1 Technical data

.

3. Noisy bearing.

The negative pressure in the 

system is too high.

Lower the negative pressure (max. 2,500 Pa).

Bearing worn out.

Replace bearing.

4. Poor suction.

Leakage in gasket/connection.

Check that the gaskets and connections are tight. Rectify if necessary.

Foreign objects in suction tube.

Check the suction tube. Remove any foreign objects.

Hole in hose.

Check the hose and replace if necessary.

MAINTENANCE SCHEDULE

Interval

Item

Inspection module

Maintenance instructions

Date

As necessary

1.1

Hose

Check that the hose is intact. Replace as necessary.

1.2

Hose reel

Clean the hose reel externally with a damp cloth.

Every three 

months

2.1

Hose

Check the attachment of the hose.

2.2

Hose reel

Check for leaks, damage and wear.

Once a year

3.1

Duct system

Check dust accumulation. Clean if necessary.

Summary of Contents for ASEM 125

Page 1: ...ASEM 65 85 125 Manual...

Page 2: ...11 Accessories 14 12 Notes 16 TABEL OF CONTENTS 1 Introduction 3 1 1 The manual 3 1 2 Declaration 3 1 3 Warranty 3 1 4 Manufacturer 3 2 Safety 4 2 1 General 4 2 2 Protective equipment 4 2 3 General wa...

Page 3: ...CE certification being voided The warranty period is one year from the date of pur chase and covers the product and its constituent parts All manufacturing defects are covered by the warranty MOVEX r...

Page 4: ...explosive environment or to extract dust and gases in explosive concentrations All work on the machine must be carried out by certified and authorised personnel For maintenance work where contact with...

Page 5: ...85 125 is a motorised hose reel intended for the evacuation of exhaust gases 3 4 Design See Fig 2 1 Bracket 2 Beam 3 Duct connection 4 Drum 5 Hose 6 Motor 7 Declutching system 8 Contact safety device...

Page 6: ...installa tions For electrical installation see Section 10 2 Circuit diagram electronics 4 3 Assembly installation National rules and regulations must always be adhered to during assembly work 4 3 1 Un...

Page 7: ...tment of end position for roll out Rotate the drum counterclockwise as viewed from the motor side until the roll out wheel 3 Fig 7 is obstructed by the stop clip 1 This is indicated by a rattling soun...

Page 8: ...Release motor disconnect switch and refit the cover 11 The hose reel is now ready for mounting and installation 4 3 6 Mounting the hose reel Fasteners used to mount the hose reel on the ceiling or wa...

Page 9: ...crews and open the cover see Fig 12 Fig 12 5 Commissioning 5 1 Start up Any faults must be rectified before turning on the power 1 Switch on the power supply 2 Check the operation of the machine White...

Page 10: ...enance schedule TROUBLESHOOTING GUIDE Symptom Possible cause Recommended action 1 The hose does not stop in the correct position Incorrect end positions have been set Adjust the end positions see sect...

Page 11: ...ical information 10 1 Technical data Dimensions inch See Fig 13 Voltage 115 V 1N Frequency 60 Hz Current 3 3 A Enclosure class IPX4 Speed 12 rpm Torque 855 IN LBS Temperature limits Operating temperat...

Page 12: ...N PE MA1 M Brown Black Blue ASEM RADIO G Y L N L N N Manual MOVEX ASEM 65 85 125 10 2 Circuit diagram electronics 10 2 1 ASEM 1 ASEM 2 10 2 2 ASEM Radio 1 3 2 4 SSB 750 120 V 1N L1 N PE MA1 M Red Blac...

Page 13: ...13 Manual FUMEX ASEM 65 85 125 1 2 3 4 5 6 7 8 9 10 11 12 17 16 15 14 13 21 20 19 18 Manual MOVEX ASEM 65 85 125 10 3 Exploded view drawing...

Page 14: ...ndicator that shows whether the damper is open or closed ASES is an energy sa ving accessory Combine with fan pressure control to further optimise the system AESM 100 125 150 Hose installation kit wit...

Page 15: ...injuries ASB Swing arm for hose reel Includes installation kit hose and pipe parts ASB 1960 ASB 4300 ASB 6300 Length 6 ft Length 14 ft Length 21 ft Weight 97 lb Weight 154 lb Weight 198 lb ASEM RADIO...

Page 16: ...XTRACTION ARMS VEHICLE EXHAUST EXTRACTION FANS FILTERS CURTAINS CONTROLS 12 Notes 104 Commerce Drive Northampton PA 18067 USA Tel 610 440 0478 Fax 610 440 0480 Email info movexinc com www movexinc com...

Reviews: