9/16
NT 1401-G00 10 18 TYPHON II e
2. GENERAL DATA (continued)
2.3.1 CONDITIONS AT SUCTION
In all cases of use, the compressor inlet suction air must
be filtered in order to eliminate particles bigger than 5 µm.
Compressor functionning under pressure :
The maximum pressure drop at suction must be lower
than 75 mbar.
A clogging indicator device turns red when the filter
needs to be changed.
Vaccum operation (SP version only) :
The maximum vacuum authorised for the intake of the
compressor is -8 bar, since the exhaust is into the
atmosphere. Pressure less than 0,3 bar at the discharge
of the compressor A vacuum breaker must be installed
on the suction circuit in order not to exceed -0,8 bar at
the compressor inlet flange.
The clogging indicator is red during the closed intake
operation. This is normal : after a vaccum operation, the
clogging indicator must be released so it becomes trans-
parent again.
REMINDER :
THE CLOGGING INDICATOR MUST NOT BE RED WHEN
THE COMPRESSOR IS IN PRESSURE OPERATION.
When the compressor is used in vaccum operation,
the temperature of the air that escapes from the
exhaust to the atmosphere may be more than 200°C.
Make sure that the flow of hot air does not cause any
damage to the surrounding elements. If necessary,
provide for protections that prevent operators from
touching the hot parts.
The maximum acceptable temperature at suction as a
function of equipment operating conditions is given in
the § T
ECHNICAL CHARACTERISTICS
.
2.3.2 CONDITIONS AT DISCHARGE
The TYPHON II compressor must be protected by a valve
that protects the compressor against accidental over-
pressure.
See Instructions 1401-E00 MISTRAL B600 TYPHON II
CHECK AND RELIEF VALVE
.
Maximum acceptable discharge pressure : see §
T
ECHNICAL CHARACTERISTICS
.
The pressures correspond to the valve opening start
pressure. In a period of 60 seconds, it is acceptable to
have a pressure of 0,2 bar higher when the valve passes
the complete flow rate.
CAUTION
Speed (rpm) :
TYPHON II N-20R
1200
1600
1600
2000
TYPHON II N-30R
1800
2400
2400
3000
TYPHON II N-19R/22L,
driving by shaft 22L
1320
1800
1800
2250
TYPHON II N-19R/22L,
driving by shaft 19R
1170
1560
1560
1950
TYPHON II N-13R/15L,
driving by shaft 15L
900
1200
1200
1500
TYPHON II N-13R/15L,
driving by shaft 13R
780
1040
1040
1300
Discharge
pressure
of compressor (bar)
2,0
2,0
2,5
2,5
Maximum inlet
temperature
allowable at this pressure (°C)
40
40
40
40