WARNING
The temperature control unit must be current less before opening!
Press the main switch on the temperature control unit and pull out the mains plug!
There is a danger of electric shock!
Caution
– risk of injury from leaking hot water or oil!
CAUTION
Waste oil has to be disposed as prescribed by law. Never let waste oil come into the
sewage system or soil.
14 Out-of-service / transport
Cool the temperature control unit down, mould drainage, turn it off, press the main switch and disconnect the
power supply. Disconnect all hoses from the temperature control unit.
The temperature control unit is to be emptied before shipping. The danger of freezing (bursting of pipes or
other components) at low temperatures can be reduced. The unit must be transported and/or stored in the
operating position.
CAUTION
Drain the unit to avoid freezing damages!
Avoid compressed air, blowing out with compressed air can damage the unit!
Never transport the unit lying
– Lying transport will destroy the unit!
15 Disposal
The temperature control unit must be drained completely and disposed of in accordance with local
regulations.
The temperature control unit can also be returned to MOULDPRO for disposal.
Summary of Contents for TCU-90L
Page 10: ... 10 User Guidelines TCU 90L 12 06 2019 Vers 003 3 2 Rear view ...
Page 38: ... 38 User Guidelines TCU 90L 12 06 2019 Vers 003 17 Electrical diagram ...
Page 39: ... 39 User Guidelines TCU 90L 12 06 2019 Vers 003 18 Water Circuit Diagram ...
Page 40: ... 40 User Guidelines TCU 90L 12 06 2019 Vers 003 19 Control Circuit diagram ...
Page 41: ... 41 User Guidelines TCU 90L 12 06 2019 Vers 003 20 Components and spare part list ...
Page 42: ... 42 User Guidelines TCU 90L 12 06 2019 Vers 003 ...