[24]
User Guidelines
– TCU-90L
12-06-2019
Vers. 003
9.1
Advanced Parameter settings
Each unit requires a different program setting. For each model is a program defined that not every parameter
must be set manually. In this program, the model specific settings are saved.
Depending on the type of PCB card, and incorporated options into the TCU unit, there are parameters that are not
activated
ST-0
Proportional band of the PID control. Self-adjusting.
Integral time of PID control. Self-adjusting.
Derivative time process. Self-adjusting.
Relay type heating. Not modifiable by the user.
SSR- Enables heating through solid state relays.
Cont- Activates the heating through the contactor KM3.
Heating ramp. Do not change without consulting the manufacturer.
This parameter is activated when entering the PID control.
In cycles 10 seconds, if the temperature has not exceeded this value in degrees,
will activate again heating. If on the contrary it has exceeded, heating is not
activated until the next cycle, which will return him to look.
Heating Brake. Do not change without consulting the manufacturer.
Heating gives 100% less the value of "br". When it comes down to this value,
start the PID control.
In pressurized water machines when set point is more than 105 °, PID control
began at 95 °.
Summary of Contents for TCU-90L
Page 10: ... 10 User Guidelines TCU 90L 12 06 2019 Vers 003 3 2 Rear view ...
Page 38: ... 38 User Guidelines TCU 90L 12 06 2019 Vers 003 17 Electrical diagram ...
Page 39: ... 39 User Guidelines TCU 90L 12 06 2019 Vers 003 18 Water Circuit Diagram ...
Page 40: ... 40 User Guidelines TCU 90L 12 06 2019 Vers 003 19 Control Circuit diagram ...
Page 41: ... 41 User Guidelines TCU 90L 12 06 2019 Vers 003 20 Components and spare part list ...
Page 42: ... 42 User Guidelines TCU 90L 12 06 2019 Vers 003 ...