[35]
User Guidelines
– TCU-90L
12-06-2019
Vers. 003
The following maintenance intervals may be required subject to use and environment:
Water filter
clean / replace
every month
Pump motor
blow out the fan
every 6 months
Hoses and pipes
check tightness
every 6 months
Pump
check tightness
every 6 months
Bolts and seals
check tightness
every 12 months
Heat transfer oil (only valid for oil units)
change
every
4‘000 working hours
For extreme service, the intervals must be shortened accordingly. For temperature control units running with
oil, the oil should be changed yearly, depending on the temperature. Comply with the directives and
recommendations of the oil manufacturer!
13.1 Inspection
Before starting the unit has to be checked the general condition of the temperature control unit, the electrical
connection and the tightness of the connections and hoses (including the consumer).
13.2 Cleaning
The temperature control unit has to be checked and cleaned periodically. Before maintenance the unit has to
be disconnected from the power supply.
13.3 Repair
Established defects must be repaired. To guarantee safety the unit must be repaired with original
MOULDPRO spare parts only.
Summary of Contents for TCU-90L
Page 10: ... 10 User Guidelines TCU 90L 12 06 2019 Vers 003 3 2 Rear view ...
Page 38: ... 38 User Guidelines TCU 90L 12 06 2019 Vers 003 17 Electrical diagram ...
Page 39: ... 39 User Guidelines TCU 90L 12 06 2019 Vers 003 18 Water Circuit Diagram ...
Page 40: ... 40 User Guidelines TCU 90L 12 06 2019 Vers 003 19 Control Circuit diagram ...
Page 41: ... 41 User Guidelines TCU 90L 12 06 2019 Vers 003 20 Components and spare part list ...
Page 42: ... 42 User Guidelines TCU 90L 12 06 2019 Vers 003 ...