[28]
User Guidelines
– TCU-90L
12-06-2019
Vers. 003
ST-5
By entering the value 1562, let us enter the St-0 and St-1.
Software version.
ST-6
Value to 0, the time to enter the programming SETS is 5 seconds.
With value 1, the time to enter the programming SETS is 15 seconds.
ST-7
Enabling communications.
Activate or communications On-OFF.
Address assigned to the TCU unit.
The first TCU unit will be address 1, if more linked machines the following would
be address 2 and so on.
Transmission speed.
"0" (2400bauds), "1" (4800 baud) and "2" (9600 baud).
Parity bit.
"0" (no parity), "1" (non parity) i "2" (even parity).