User Guidelines
– TCU-200
12-06-2019
Vers. 003
Interface type. "420" (4-20mA) or "485" (RS485).
When you select "485", the following parameter dEn not appear.
Data enable.
When the interface type is 420 and only have one TCU linked to the MASTER
machine, dEn parameter value is "1" (close circuit); if more than one TCU linked
all will have dEn value "0" less the last one it will have dEn value “1”.
ST-8
Fluid level setting.
Not modifiable by the user.
Select if the level control is done by electrode "ELEC" or buoy "BuOY".
Extra time level detection.
Water filling valve retard disconnection time. Value in seconds.
NO CHANGE WITHOUT CONSULT THE MANUFACTURER
Extra time no level detection.
Water filling valve retard connection time. Value in seconds.
NO CHANGE WITHOUT CONSULT THE MANUFACTURER
Display activation drive pump.
Activate or not the on-off display.
Alarm output drive pump.
Value in bars.
Initial scale transducer drive pump.
Value in bars.
NO CHANGE WITHOUT CONSULT THE MANUFACTURER
Full-scale transducer drive pump.
Value in bars.
NO CHANGE WITHOUT CONSULT THE MANUFACTURER
Display Activation return pressure.
Activate or not the display. On-off
Initial scale return transducer drive pump.
Value in bars.
NO CHANGE WITHOUT CONSULT THE MANUFACTURER
Summary of Contents for TCU-200
Page 10: ... 10 User Guidelines TCU 200 12 06 2019 Vers 003 3 2 Rear view ...
Page 38: ... 38 User Guidelines TCU 200 12 06 2019 Vers 003 17 Electrical diagram ...
Page 39: ... 39 User Guidelines TCU 200 12 06 2019 Vers 003 18 Water Circuit Diagram ...
Page 40: ... 40 User Guidelines TCU 200 12 06 2019 Vers 003 19 Control Circuit diagram ...
Page 41: ... 41 User Guidelines TCU 200 12 06 2019 Vers 003 20 Components and spare part list ...