background image

Gv224_01a_oi_e.docx / Okt-22 

 

Page 14 / 17 

5.

 

Technical Specifications 

 

Technical Specifications 

Power supply: 

Input voltage: 
Protection circuit: 
Ripple: 
Consumption: 
Connections: 

10 … 30 VDC 

 

Reverse polarity protection 

 10 % at 24 VDC 

approx. 25 mA, with an unloaded encoder supply 
screw terminal, 1,5 mm² / AWG16 

Encoder supply: 

Output voltage 1: 
Output current: 
Output voltage 2: 
Output current: 
Protection: 
Connections: 
Further possibilities: 

24 VDC (ca. 0,8 V less than supply voltage) 
max. 250 mA, (galvanically connected with the power supply) 
5 VDC 
max. 500 mA, (galvanically connected with the power supply) 
short circuit proof 
screw terminal, 1,5 mm² / AWG16, 9-pin 

a)

 

Externally by a separate source 

b)

 

By the same source that supplies the splitter 

(10…30V)

 

Incremental input: 

Signal levels (selectable): 
 
 
 
Channels: 
Frequency: 
 
 
Connections: 

RS422 / TTL (differential voltage > 0,5 V), 
HTL Differential (differential voltage > 2 V), 
HTL (asymmetrical

): LOW 0 … 6 V, HIGH 8 … 4

0 V  

TTL (asymmetrical): LOW < 0,8 V, HIGH >2,0 V 
asymmetrical: A, B, Z or symmetrical: A, /A, B, /B, Z, /Z  
max. 1 MHz at RS422 / TTL  
max. 500 kHz at HTL Differential 
max. 250kHz at SE TTL / SE HTL 
screw terminal, 1,5 mm² / AWG16 

Incremental outputs: 

Number of outputs: 
 
Output logic: 
Signal levels: 
 
Signal delay time: 
Output current: 
Protection: 
Connections: 

2 (GT222), 4 (GT224/GV224) 
resp. 8 (GT228/GV228), 
push-pull 

5 … 30 V

 

(can be supplied by respective ext. COM+ terminal) 
approx. 160 ns 
max. 30 mA 
short-circuit proof 
screw terminal, 1,5 mm² / AWG16 

Potential separation: 

GT222 / GT224 
GT228 

Potential separation between input and the outputs as well as 
all outputs among each other. 

Indicators: 

Number of indicators: 
Function: 

2 LEDs 
1 x green 

for “ready for operate” state

 

1 x yellow for error detection at the inputs A, B, Z 

 

 

 

Summary of Contents for GT222

Page 1: ...e specified by external power supply Short circuit proof 5VDC and 24VDC encoder supply Available devices GV224 Pulse splitter with 1 encoder input and 4 outputs GV228 Pulse splitter with 1 encoder inp...

Page 2: ...escription en fran ais est disponible sur https www motrona com fileadmin files bedienungsanleitungen Gv224_f pdf Version Description GV224_01a March 22 tgo mbo First edition GV22x GT22x Legal notices...

Page 3: ...iagram GT222 GT224 und GT228 10 4 Electrical Connections und LED Function 11 4 1 Power Supply and LEDs 11 4 2 Auxiliary Encoder Supply 11 4 3 Impuls Inputs 12 4 3 1 Encoders with differential output O...

Page 4: ...he right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual T...

Page 5: ...er indicated as separator Incoming as well as outgoing wires and wires for extra low voltages ELV must be separated from dangerous electrical cables SELV circuits by using a double resp increased isol...

Page 6: ...be mounted in a metal enclosure with sufficient distance to sources of electromagnetic noise Run signal and control cables apart from power lines and other cables emitting electromagnetic noise Please...

Page 7: ...ential voltage 0 5 V HTL Differential Differential voltage 2 V HTL asymmetrical LOW 0 6 V HIGH 8 40 V TTL asymmetrical LOW 0 8 V HIGH 2 0 V max 1 MHz at RS422 TTL max 500 kHz at HTL Differential max 2...

Page 8: ...mounting kit 72 x 144 x 90 5 mm 2 83 x 5 67 x 2 38 inches w x h x d inclusive connectors mounting kit Weight approx 400 g Device parameterization Over 3 position DIL switch ber 8 position DIL switch e...

Page 9: ...st advantageous with impulse distribution among expanded production lines with adverse conditions of EMC grounding potential shift The encoder input is switch selectable for operation with either stan...

Page 10: ...Gv224_01a_oi_e docx Okt 22 Page 10 17 3 1 Block diagram GV224 und GV228 3 2 Block diagram GT222 GT224 und GT228...

Page 11: ...unit The lower LED yellow signals a possible error e g wire break at the input channels A A B B and or Z Z in case of differential input signals switched on error evaluation DIL 3 ON and corresponding...

Page 12: ...ential 10 30 V DIL switch DIL1 OFF DIL2 OFF 4 3 2 Encoders with differential output Output level RS422 5V DIL switch DIL1 ON DIL2 OFF 4 3 3 Encoders with single ended output without inverted signals O...

Page 13: ...Com input of the mating connector is responsible for the output level For the types with potential separation GT22x in addition to ext COM and also the corresponding ext GND connection of the corresp...

Page 14: ...Signal levels selectable Channels Frequency Connections RS422 TTL differential voltage 0 5 V HTL Differential differential voltage 2 V HTL asymmetrical LOW 0 6 V HIGH 8 40 V TTL asymmetrical LOW 0 8...

Page 15: ...54 x 100 x 131 mm 2 13 x 3 94 x 5 16 inches w x h x d without connectors 54 x 118 x 140 mm 2 13 x 4 65 x 5 51 inches w x h x d inclusive connectors approx 240 g IP20 Ambient temperature Operation Stor...

Page 16: ...Gv224_01a_oi_e docx Okt 22 Page 16 17 6 Dimensions GV224 GT222 GT224 GV228 GT228...

Page 17: ...ctor Encoder input via bus connector Optionally 4 or 8 additional outputs with or without potential separation see below Output level is specified by external voltage supply Available devices EV224 Ex...

Reviews: