Gv224_01a_oi_e.docx / Okt-22
Page 15 / 17
Housing:
Material:
Mounting:
Dimensions (B x H x T):
Weight:
Dimensions (B x H x T):
Weight:
Protection:
plastic
mounting rail (EN 60715, 35mm C-Profile)
GV224/GT222/GT224:
34 x 100 x 131 mm / 1.34 x 3.94 x 5.16 inches (w x h x d)
(without connectors)
34 x 118 x 140 mm / 1.34 x 4.65 x 5.51 inches (w x h x d)
(inclusive connectors))
approx. 160 g
GV228/GT228:
54 x 100 x 131 mm / 2.13 x 3.94 x 5.16 inches (w x h x d)
(without connectors)
54 x 118 x 140 mm / 2.13 x 4.65 x 5.51 inches (w x h x d)
(inclusive connectors)
approx. 240 g
IP20
Ambient temperature:
Operation:
Storage:
-
20 °C … +60 °C /
-
4 °F … +140 °F (not condensing
)
-
30 °C … +75° C /
-
22 °F … +167 °F (not condensing)
Failure rate:
MTBF in years:
(continuous operation at
60 °C / 140 °F)
GT222: 131,7 a
GV224: 120,9 a / GT224: 102,0 a
GV228: 85,4 a / GT228: 67,7 a
Conformity & standards:
EMC 2014/30/EU:
RoHS (
Ⅱ
) 2011/65/EU
RoHS (
Ⅲ
) 2015/863:
EN 61326-1: 2013 for industrial location
EN 55011: 2016 + A1: 2017 + A11: 2020 Class A
EN IEC 63000: 2018