1.

 

Safety Instructions and Responsibility 

1.1.

 

General Safety Instructions 

This operation manual is a significant component of the unit and includes important rules and 
hints about the installation, function and usage. Non-observance can result in damage and/or 
impairment of the functions to the unit or the machine or even in injury to persons using the 
equipment!  

 

Please read the following instructions carefully before operating the device and observe all 
safety and warning instructions! Keep the manual for later use.  

 

A pertinent qualification of the respective staff is a fundamental requirement in order to use 
these manual. The unit must be installed, connected and put into operation by a qualified 
electrician. 

 

Liability exclusion: The manufacturer is not liable for personal injury and/or damage to property 
and for consequential damage, due to incorrect handling, installation and operation. Further 
claims, due to errors in the operation manual as well as misinterpretations are excluded from 
liability. 

 

In addition the manufacturer reserve the right to modify the hardware, software or operation 
manual at any time and without prior notice. Therefore, there might be minor differences 
between the unit and the descriptions in operation manual. 

 

The raiser respectively positioner is exclusively responsible for the safety of the system and 
equipment where the unit will be integrated.  

 

During installation or maintenance all general and also all country- and application-specific 
safety rules and standards must be observed.  

 

If the device is used in processes, where a failure or faulty operation could damage the system 
or injure persons, appropriate precautions to avoid such consequences must be taken. 
 

1.2.

 

Use according to the intended purpose 

The unit is intended exclusively for use in industrial machines, constructions and systems. Non-
conforming usage does not correspond to the provisions and lies within the sole responsibility 
of the user. The manufacturer is not liable for damages which has arisen through unsuitable 
and improper use.  

 

Please note that device may only be installed in proper form and used in a technically perfect 
condition - in accordance to the Technical Specifications (see chapte

5

). The device is not 

suitable for operation in explosion-proof areas or areas which are excluded by the EN 61010-1 
standard. 

 

 

Summary of Contents for GT222

Page 1: ...e specified by external power supply Short circuit proof 5VDC and 24VDC encoder supply Available devices GV224 Pulse splitter with 1 encoder input and 4 outputs GV228 Pulse splitter with 1 encoder inp...

Page 2: ...escription en fran ais est disponible sur https www motrona com fileadmin files bedienungsanleitungen Gv224_f pdf Version Description GV224_01a March 22 tgo mbo First edition GV22x GT22x Legal notices...

Page 3: ...iagram GT222 GT224 und GT228 10 4 Electrical Connections und LED Function 11 4 1 Power Supply and LEDs 11 4 2 Auxiliary Encoder Supply 11 4 3 Impuls Inputs 12 4 3 1 Encoders with differential output O...

Page 4: ...he right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual T...

Page 5: ...er indicated as separator Incoming as well as outgoing wires and wires for extra low voltages ELV must be separated from dangerous electrical cables SELV circuits by using a double resp increased isol...

Page 6: ...be mounted in a metal enclosure with sufficient distance to sources of electromagnetic noise Run signal and control cables apart from power lines and other cables emitting electromagnetic noise Please...

Page 7: ...ential voltage 0 5 V HTL Differential Differential voltage 2 V HTL asymmetrical LOW 0 6 V HIGH 8 40 V TTL asymmetrical LOW 0 8 V HIGH 2 0 V max 1 MHz at RS422 TTL max 500 kHz at HTL Differential max 2...

Page 8: ...mounting kit 72 x 144 x 90 5 mm 2 83 x 5 67 x 2 38 inches w x h x d inclusive connectors mounting kit Weight approx 400 g Device parameterization Over 3 position DIL switch ber 8 position DIL switch e...

Page 9: ...st advantageous with impulse distribution among expanded production lines with adverse conditions of EMC grounding potential shift The encoder input is switch selectable for operation with either stan...

Page 10: ...Gv224_01a_oi_e docx Okt 22 Page 10 17 3 1 Block diagram GV224 und GV228 3 2 Block diagram GT222 GT224 und GT228...

Page 11: ...unit The lower LED yellow signals a possible error e g wire break at the input channels A A B B and or Z Z in case of differential input signals switched on error evaluation DIL 3 ON and corresponding...

Page 12: ...ential 10 30 V DIL switch DIL1 OFF DIL2 OFF 4 3 2 Encoders with differential output Output level RS422 5V DIL switch DIL1 ON DIL2 OFF 4 3 3 Encoders with single ended output without inverted signals O...

Page 13: ...Com input of the mating connector is responsible for the output level For the types with potential separation GT22x in addition to ext COM and also the corresponding ext GND connection of the corresp...

Page 14: ...Signal levels selectable Channels Frequency Connections RS422 TTL differential voltage 0 5 V HTL Differential differential voltage 2 V HTL asymmetrical LOW 0 6 V HIGH 8 40 V TTL asymmetrical LOW 0 8...

Page 15: ...54 x 100 x 131 mm 2 13 x 3 94 x 5 16 inches w x h x d without connectors 54 x 118 x 140 mm 2 13 x 4 65 x 5 51 inches w x h x d inclusive connectors approx 240 g IP20 Ambient temperature Operation Stor...

Page 16: ...Gv224_01a_oi_e docx Okt 22 Page 16 17 6 Dimensions GV224 GT222 GT224 GV228 GT228...

Page 17: ...ctor Encoder input via bus connector Optionally 4 or 8 additional outputs with or without potential separation see below Output level is specified by external voltage supply Available devices EV224 Ex...